{"product_id":"weidmuller-1315680000-ur20-4ao-ui-16-remote-i-o-module","title":"Weidmuller 1315680000 UR20-4AO-UI-16 Remote I\/O Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe Weidmuller 1315680000 UR20-4AO-UI-16 is a remote I\/O module, IP20, designed for analog signals output with 4 channels for current\/voltage. It allows connection with 2- or 4-wire technology and features channel-by-channel measurement range definition using parameterization. Each channel has its own status LED.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e4-channel analogue output module\u003c\/li\u003e\n  \u003cli\u003eConnection system: PUSH IN\u003c\/li\u003e\n  \u003cli\u003eGalvanic isolation: between field and system bus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eThis module controls up to 4 analogue actuators with an accuracy of 0.05% of the measurement-range end value.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Weidmuller\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 1315680000\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: China\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVersion\u003c\/strong\u003e: Remote I\/O module, IP20, Analog signals, Output, 4-channel, Current\/Voltage\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOrder No.\u003c\/strong\u003e: 1315680000\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: 1. U (0\t5 V, 0\t10 V, 1\t5 V, 2\t10 V, \t10 V)\n2. I (0–20 mA or 4–20 mA)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGTIN (EAN)\u003c\/strong\u003e: 4050118118803\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDepth\u003c\/strong\u003e: 76 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDepth (inches)\u003c\/strong\u003e: 2.992 inch\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeight\u003c\/strong\u003e: 120 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeight (inches)\u003c\/strong\u003e: 4.724 inch\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWidth\u003c\/strong\u003e: 11.5 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWidth (inches)\u003c\/strong\u003e: 0.453 inch\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNet weight\u003c\/strong\u003e: 87 g\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStorage temperature\u003c\/strong\u003e: -40 \tC ... +85 \tC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: -20 \tC...60 \tC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS Compliance Status\u003c\/strong\u003e: Compliant with exemption\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS Exemption (if applicable\/known)\u003c\/strong\u003e: 7a, 7cI\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH SVHC\u003c\/strong\u003e: Lead 7439-92-1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSCIP\u003c\/strong\u003e: 82327f13-cd27-455a-ab5b-a62e1996dcf8\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e: 0,1 % FSR max., 0,05 % FSR typ.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eActuator connection\u003c\/strong\u003e: 2-wire (automatic detection)\n4-wire\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eActuator supply min.\u003c\/strong\u003e: 0 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eActuator supply nominal\u003c\/strong\u003e: 185 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eActuator supply max.\u003c\/strong\u003e: 185 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCross-talk between the channels in FSR\u003c\/strong\u003e: 0.001 %\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndividual channel diagnosis\u003c\/strong\u003e: No\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLoad impedance current\u003c\/strong\u003e: \u0026lt;600\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eload impedance voltage\u003c\/strong\u003e: \u0026gt; 1 k\t (at \u0026gt;50 \tC ambient temperature, max. total sensor current = 25 mA)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMax. error between T min. and T max. in FSR\u003c\/strong\u003e: 220 %\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule diagnosis\u003c\/strong\u003e: Yes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMonotonicity\u003c\/strong\u003e: Yes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber analogue outputs\u003c\/strong\u003e: 4\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput current as per application min.\u003c\/strong\u003e: 0 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput current as per application nominal\u003c\/strong\u003e: 185 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput current as per application max.\u003c\/strong\u003e: 185 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput variable\u003c\/strong\u003e: Voltage (0...5 V, 0...10 V, 1...5 V, 2...10 V, \t10 V, \t5 V)\nCurrent (0...20 mA or 4...20 mA)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRepeat accuracy\u003c\/strong\u003e: \u0026lt;1 mV eff.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResolution\u003c\/strong\u003e: 16 Bit\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResponse time\u003c\/strong\u003e: 1 ms \/ 4 channels\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShort-circuit-proof\u003c\/strong\u003e: Yes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSimultaneity factor min.\u003c\/strong\u003e: 0 %\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSimultaneity factor nominal\u003c\/strong\u003e: 100 %\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSimultaneity factor max.\u003c\/strong\u003e: 100 %\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSubstitute values\u003c\/strong\u003e: Yes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature coefficient\u003c\/strong\u003e: 20 ppm voltage \/ 31 ppm current measurement \/ \tK\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType of connection\u003c\/strong\u003e: PUSH IN\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire connection cross section, finely stranded, max.\u003c\/strong\u003e: 1.5 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire connection cross section, finely stranded, min.\u003c\/strong\u003e: 0.14 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire cross-section, finely stranded, max. (AWG)\u003c\/strong\u003e: AWG 16\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire cross-section, finely stranded, min. (AWG)\u003c\/strong\u003e: AWG 26\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire cross-section, solid, max.\u003c\/strong\u003e: 1.5 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire cross-section, solid, max. (AWG)\u003c\/strong\u003e: AWG 16\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire cross-section, solid, min.\u003c\/strong\u003e: 0.14 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire cross-section, solid, min. (AWG)\u003c\/strong\u003e: AWG 26\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAir humidity (operation)\u003c\/strong\u003e: 10% to 95%, non-condensing as per DIN EN 61131-2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAir humidity (storage)\u003c\/strong\u003e: 10% to 95%, non-condensing as per DIN EN 61131-2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAir humidity (transport)\u003c\/strong\u003e: 10% to 95%, non-condensing as per DIN EN 61131-2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAir pressure (operation)\u003c\/strong\u003e: 795 hPa (height \t 2000 m) as per DIN EN 61131-2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAir pressure (storage)\u003c\/strong\u003e: 1013 hPa (height 0 m) to 700 hPa (height 3000 m) as per DIN EN 61131-2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAir pressure (transport)\u003c\/strong\u003e: 1013 hPa (height 0 m) to 700 hPa (height 3000 m) as per DIN EN 61131-2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting rail\u003c\/strong\u003e: TS 35\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePollution severity\u003c\/strong\u003e: 2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShock\u003c\/strong\u003e: 15 g over 11 ms, half sinus wave, acc. to IEC 60068-2-27\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSurge voltage category\u003c\/strong\u003e: II\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTest voltage\u003c\/strong\u003e: 500 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 94 flammability rating\u003c\/strong\u003e: V-0\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVibration resistance\u003c\/strong\u003e: 5 Hz \t f \t 8.4 Hz: 3.5-mm amplitude as per IEC 60068-2-6\n8.4 Hz \t f \t 150 Hz: 1 g acceleration as per IEC 60068-2-6\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCurrent consumption from I OUT\u003c\/strong\u003e: 85 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCurrent consumption from I sys, typ.\u003c\/strong\u003e: 8 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSupply voltage\u003c\/strong\u003e: 24 V DC +20 %\/ -15 %\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnection type\u003c\/strong\u003e: PUSH IN\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDiagnostic data\u003c\/strong\u003e: 1 Bit\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eField bus protocol\u003c\/strong\u003e: PROFINET IRT\nPROFINET RT\nCC-Link IE TSN\nPROFIBUS DP-V1\nEtherCAT\nModbus\/TCP\nEtherNet\/IP\nCANopen\nDeviceNet\nPOWERLINK\nCC-Link\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGalvanic isolation\u003c\/strong\u003e: 500 V DC between the current paths\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterface\u003c\/strong\u003e: u-remote system bus\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule type\u003c\/strong\u003e: Analogue output module\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eParameter data\u003c\/strong\u003e: 12 Byte\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProcess data\u003c\/strong\u003e: 8 Byte\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTransmission speed of system bus, max.\u003c\/strong\u003e: 48 MBit\/s\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":51150082703666,"sku":"1315680000","price":377.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/305963277.jpg?v=1778605519","url":"https:\/\/voomisupply.com\/products\/weidmuller-1315680000-ur20-4ao-ui-16-remote-i-o-module","provider":"Voomi Supply","version":"1.0","type":"link"}