{"product_id":"trane-a952v060bu4sa-furnace-ac-system-60-000-btu-replaces-a952v060bu3sa-a952v060bu4sa","title":"Trane A952V060BU4SA Two Stage Variable Speed Gas Furnace 60000 Btu\/h 96% Afue Upflow Horizontal 17.5 Inch Cabinet","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe Trane A952V060BU4SA is a two-stage, variable-speed condensing gas furnace rated at 60,000 BTU\/h input capacity and 96% AFUE. It is designed for upflow installation and is convertible to horizontal right or horizontal left configurations, making it suitable for a wide range of residential mechanical room layouts. The variable-speed ECM draft inducer motor supports consistent airflow delivery across both heating stages. A 24-volt control circuit governs staging and blower operation. Licensed HVAC technicians perform installation and commissioning on this equipment in accordance with applicable mechanical and gas codes.\u003c\/p\u003e\n\u003cp\u003eThe A952V060BU4SA fits into residential forced-air heating systems where space or orientation constraints require installation flexibility. The 17.5-inch-wide cabinet is an industry-standard width, allowing straightforward replacement in existing equipment openings. The unit is compatible with industry-standard evaporator coils and accessories for split-system cooling integration. Return air temperature range is 45 degrees F to 80 degrees F. Second-stage temperature rise range is 35 degrees F to 65 degrees F. Nominal airflow is 1,600 CFM, with setup options available down to lower CFM-per-ton values for system balancing.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e96% AFUE two-stage condensing operation reduces fuel consumption compared to single-stage designs\u003c\/li\u003e\n  \u003cli\u003eVariable-speed ECM blower motor supports quieter low-stage operation and improved airflow consistency\u003c\/li\u003e\n  \u003cli\u003eUpflow cabinet convertible to horizontal right or horizontal left without a separate conversion kit\u003c\/li\u003e\n  \u003cli\u003e17.5-inch industry-standard cabinet width fits existing residential equipment footprints\u003c\/li\u003e\n  \u003cli\u003eAir-tight cabinet construction with 1% or less air leakage per ASHRAE 193\u003c\/li\u003e\n  \u003cli\u003eOpen vestibule design provides 34-inch clearance height for access and component serviceability\u003c\/li\u003e\n  \u003cli\u003e24-volt control circuit compatible with standard residential thermostat wiring configurations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eThe A952V060BU4SA is documented as a component of upflow split-system configurations pairing with a 2-ton outdoor condensing unit and a matching evaporator coil. Cabinet dimensions are compatible with industry-standard coil cabinets and accessories. Consult the RunTru A952V installation documentation for approved system pairings and coil matchups.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed HVAC technician in compliance with the International Fuel Gas Code, local gas codes, and the manufacturer installation manual for the A952V series. Shut off gas supply and disconnect electrical power at the disconnect or breaker before any service or installation work. Vent this condensing furnace using approved PVC or CPVC vent piping per the installation manual specifications — never use B-vent or single-wall metal vent pipe on a 96% AFUE condensing appliance. Verify condensate drainage is properly trapped and routed per local plumbing codes before startup.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Capacity\u003c\/strong\u003e: 60,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAFUE\u003c\/strong\u003e: 96.0%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStages\u003c\/strong\u003e: Two Stage\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBlower Motor Type\u003c\/strong\u003e: Variable Speed ECM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNominal Airflow\u003c\/strong\u003e: 1,600 CFM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eControl Voltage\u003c\/strong\u003e: 24 volts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply\u003c\/strong\u003e: 120V \/ 1-phase \/ 60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInstallation Orientation\u003c\/strong\u003e: Upflow, Convertible to Horizontal Left or Horizontal Right\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReturn Air Temperature Range\u003c\/strong\u003e: 45 degrees F to 80 degrees F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecond Stage Temperature Rise Range\u003c\/strong\u003e: 35 degrees F to 65 degrees F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCabinet Width\u003c\/strong\u003e: 17.5 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCabinet Depth\u003c\/strong\u003e: 28.75 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOpen Vestibule Height\u003c\/strong\u003e: 34 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAir Leakage\u003c\/strong\u003e: 1% or less per ASHRAE 193\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Trane\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: A952V060BU4SA\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TRANE","offers":[{"title":"Default Title","offer_id":51195727872306,"sku":"A952V060BU4SA","price":2780.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/308796121.jpg?v=1780589083","url":"https:\/\/voomisupply.com\/products\/trane-a952v060bu4sa-furnace-ac-system-60-000-btu-replaces-a952v060bu3sa-a952v060bu4sa","provider":"Voomi Supply","version":"1.0","type":"link"}