{"product_id":"trane-a5hp5048a1000-heat-pump-air-conditioner-system-48000-btu","title":"Trane A5HP5048A1000 Heat Pump Condenser 48000 Btu 4 Ton 15.2 SEER2 R-454B Single Stage","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe Trane A5HP5048A1000 is a single-stage, split-system heat pump condenser rated at 48,000 BTU\/h (4 tons) with a 15.2 SEER2 efficiency rating. It operates on R-454B refrigerant and runs on a 208\/230-volt, single-phase, 60 Hz power supply. The unit features an all-aluminum coil construction and a 24-volt system control interface. Designed for ducted residential central HVAC applications, this outdoor condenser pairs with a compatible indoor air handler or coil to deliver both heating and cooling from a single system. Licensed HVAC technicians handle the installation and commissioning of this equipment.\u003c\/p\u003e\n\u003cp\u003eThis condenser is intended for residential ducted split-system installations where a single-stage, R-454B heat pump is specified. It is suited to applications requiring 4-ton nominal capacity with 208\/230-volt single-phase power. The A5HP5048A1000 is part of the RunTru by Trane product family and is positioned for new construction and replacement projects where current refrigerant regulations favor low-GWP refrigerants such as R-454B. It delivers year-round heating and cooling performance in a single outdoor unit footprint.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e48,000 BTU\/h nominal cooling capacity at 4-ton rating\u003c\/li\u003e\n  \u003cli\u003e15.2 SEER2 efficiency rating meets current federal minimum efficiency standards\u003c\/li\u003e\n  \u003cli\u003eR-454B refrigerant — low-GWP replacement for R-410A, compliant with current regulations\u003c\/li\u003e\n  \u003cli\u003eAll-aluminum coil construction for corrosion resistance\u003c\/li\u003e\n  \u003cli\u003e24-volt system control interface compatible with standard low-voltage thermostat wiring\u003c\/li\u003e\n  \u003cli\u003eSingle-stage operation with one outdoor propeller fan\u003c\/li\u003e\n  \u003cli\u003eSound power level rated at 72 dB(A) per AHRI Standard 270-2008\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM split-system heat pump condenser within the RunTru by Trane A5HP5 product family, intended for use with a compatible ducted indoor air handler or coil section in a residential split-system application.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed HVAC technician holding appropriate EPA Section 608 refrigerant handling certification, as R-454B is a mildly flammable A2L refrigerant requiring compliant equipment and procedures. Disconnect and lock out all electrical power before servicing the unit. Follow all applicable local mechanical and electrical codes, including NEC requirements for outdoor disconnect and branch circuit sizing based on the rated load amperage. Do not mix refrigerants or recharge with any refrigerant other than R-454B as specified on the unit nameplate.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNominal Capacity\u003c\/strong\u003e: 48,000 BTU\/h (4 Ton)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSEER2\u003c\/strong\u003e: 15.2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRefrigerant Type\u003c\/strong\u003e: R-454B\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage \/ Phase \/ Frequency\u003c\/strong\u003e: 208\/230 volts \/ 1 Phase \/ 60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated Load Amps (RLA)\u003c\/strong\u003e: 18.1 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLocked Rotor Amps (LRA)\u003c\/strong\u003e: 95.0 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Control Voltage\u003c\/strong\u003e: 24 volts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Stages\u003c\/strong\u003e: 1 (Single Stage)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Fans\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCoil Material\u003c\/strong\u003e: All Aluminum\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSound Power Level\u003c\/strong\u003e: 72 dB(A) (AHRI Standard 270-2008)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Height\u003c\/strong\u003e: 44.625 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Width (Side A)\u003c\/strong\u003e: 34.25 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFactory Installed Start Components\u003c\/strong\u003e: No\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompressor Heat\u003c\/strong\u003e: No\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInsulation \/ Sound Blanket\u003c\/strong\u003e: No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Trane\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: A5HP5048A1000\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TRANE","offers":[{"title":"Default Title","offer_id":51202477916466,"sku":"A5HP5048A1000","price":3367.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/308796066.webp?v=1780588751","url":"https:\/\/voomisupply.com\/products\/trane-a5hp5048a1000-heat-pump-air-conditioner-system-48000-btu","provider":"Voomi Supply","version":"1.0","type":"link"}