{"product_id":"trane-a5hp5030a1000-2-5-ton-15-2-seer2-heat-pump-condenser","title":"Trane A5HP5030A1000 Split System Heat Pump Condenser 30000 Btu 2.5 Ton 15.2 SEER2 208-230V R-454B Residential","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe Trane A5HP5030A1000 is a single-stage, split-system heat pump condenser rated at 30,000 BTU\/h (2.5 tons) with a 15.2 SEER2 efficiency rating and an HSPF2 of 8.1. Charged with R-454B refrigerant, this outdoor unit delivers both heating and cooling through a single refrigerant circuit, making it suited for year-round residential comfort. It operates on a 208-230V\/1-phase\/60 Hz power supply with 24-volt system controls. The unit features an all-aluminum coil construction and a PSC blower motor. Licensed HVAC technicians install and commission this condenser as the outdoor half of a ducted central split system paired with a compatible indoor air handler.\u003c\/p\u003e\n\u003cp\u003eThis unit is intended for residential ducted central split-system installations. It is designed for single-stage on-off operation and pairs with a compatible air handler to form a complete heating and cooling system. The A5HP5030A1000 is part of the RunTru by Trane A5HP50 series and is rated in accordance with AHRI standards. Typical applications include new construction and replacement installations in single-family residential settings where a 2.5-ton capacity is required and R-454B refrigerant compatibility is specified.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e30,000 BTU\/h (2.5 ton) single-stage heat pump operation for both heating and cooling\u003c\/li\u003e\n  \u003cli\u003e15.2 SEER2 efficiency rating with HSPF2 of 8.1\u003c\/li\u003e\n  \u003cli\u003eR-454B refrigerant — A2L low-global-warming-potential refrigerant\u003c\/li\u003e\n  \u003cli\u003eAll-aluminum coil construction for corrosion resistance and durability\u003c\/li\u003e\n  \u003cli\u003e208-230V\/1-phase\/60 Hz power supply with 24-volt system control interface\u003c\/li\u003e\n  \u003cli\u003ePSC blower motor with 23-inch blower diameter\u003c\/li\u003e\n  \u003cli\u003eRated per AHRI Standard 270-2008 for sound power levels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned for use as the outdoor condenser in a ducted residential split-system heat pump installation paired with a compatible R-454B indoor air handler. Confirmed system pairing referenced in supplier data includes the A5AHC003A1B30A air handler.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed HVAC technician holding the appropriate EPA Section 608 refrigerant-handling certification, as this unit uses R-454B, an A2L classified refrigerant requiring specific handling procedures. Disconnect and lock out all electrical power to the system before making any electrical or refrigerant connections. Refer to the manufacturer installation, operation, and maintenance documentation for proper line set sizing, refrigerant charge procedure, and low-voltage thermostat wiring. Local mechanical and electrical codes apply; consult applicable AHRI, NEC, and jurisdiction-specific requirements before commissioning.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCooling Capacity\u003c\/strong\u003e: 30,000 BTU\/h (2.5 tons)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSEER2 Rating\u003c\/strong\u003e: 15.2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHSPF2 Rating\u003c\/strong\u003e: 8.1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRefrigerant\u003c\/strong\u003e: R-454B\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage \/ Phase \/ Frequency\u003c\/strong\u003e: 208-230V \/ 1-phase \/ 60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Control Voltage\u003c\/strong\u003e: 24 volts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRunning Load Amps (RLA)\u003c\/strong\u003e: 10.4 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLocked Rotor Amps (LRA)\u003c\/strong\u003e: 71.0 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Overcurrent Protection (MOCP)\u003c\/strong\u003e: 25 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBlower Motor Type\u003c\/strong\u003e: PSC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBlower Diameter\u003c\/strong\u003e: 23 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Height (A dimension)\u003c\/strong\u003e: 36.75 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Width (B dimension)\u003c\/strong\u003e: 32.625 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Depth (C dimension)\u003c\/strong\u003e: 29.75 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCoil Material\u003c\/strong\u003e: All-aluminum\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompressor Stages\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSound Power Level\u003c\/strong\u003e: 75 dB(A) (A-weighted, per AHRI Standard 270-2008)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFactory-Installed Start Components\u003c\/strong\u003e: No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Trane\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: A5HP5030A1000\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TRANE","offers":[{"title":"Default Title","offer_id":51204100194610,"sku":"A5HP5030A1000","price":2862.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/308795400.jpg?v=1780588759","url":"https:\/\/voomisupply.com\/products\/trane-a5hp5030a1000-2-5-ton-15-2-seer2-heat-pump-condenser","provider":"Voomi Supply","version":"1.0","type":"link"}