{"product_id":"trane-a5hp5018a1000-runtru-1-5-ton-15-2-seer2-heat-pump","title":"Trane A5HP5018A1000 Split System Heat Pump Condenser 1.5 Ton 15.2 SEER2 R-454B Residential","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe Trane A5HP5018A1000 is a 1.5-ton single-stage split system heat pump condenser rated at 15.2 SEER2 and designed for residential ducted applications. Operating on R-454B refrigerant and powered by a 208\/230V single-phase 60 Hz supply, this outdoor unit provides both heating and cooling through a paired air handler or coil cabinet. Running load amps are 7.8 A with a locked rotor amp rating of 47.5 A. Licensed HVAC technicians install and commission this unit as part of a matched split system assembly.\u003c\/p\u003e\n\u003cp\u003eThe A5HP5018A1000 is intended for residential split system installations where a 1.5-ton heat pump solution is required. It is rated under AHRI Standard 270-2008 for sound power, with an A-weighted sound power level of 75 dB(A). The unit carries a nominal capacity of 18,000 BTU\/h and is suited for single-zone ducted systems in light residential construction. No factory-installed start components or compressor heat are included in the base configuration.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e15.2 SEER2 efficiency rating for compliance with current regional efficiency standards\u003c\/li\u003e\n  \u003cli\u003eR-454B refrigerant — lower global warming potential alternative to R-410A\u003c\/li\u003e\n  \u003cli\u003eSingle-stage operation with 208\/230V single-phase 60 Hz electrical supply\u003c\/li\u003e\n  \u003cli\u003eA-weighted sound power level of 75 dB(A) per AHRI Standard 270-2008\u003c\/li\u003e\n  \u003cli\u003e7.8 RLA and 47.5 LRA ratings support standard residential disconnect and overcurrent sizing\u003c\/li\u003e\n  \u003cli\u003eRunTru by Trane platform — designed for use with compatible matched indoor components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned for use in matched residential split system heat pump configurations on the RunTru by Trane and Ameristar by American Standard platforms. Specific matched indoor coil and air handler pairings must be confirmed against current AHRI certified system combinations to ensure rated efficiency performance.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed HVAC technician in accordance with local mechanical codes and the current edition of applicable national standards. Disconnect and lock out all electrical power before servicing or making refrigerant connections. Because this unit uses R-454B, technicians must use dedicated tools and recovery equipment rated for A2L refrigerants and follow all applicable safety requirements for mildly flammable refrigerants. Verify that the indoor coil and air handler are listed in a certified matched system combination before startup.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNominal Capacity\u003c\/strong\u003e: 18,000 BTU\/h (1.5 ton)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSEER2 Rating\u003c\/strong\u003e: 15.2 SEER2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRefrigerant\u003c\/strong\u003e: R-454B\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage \/ Phase \/ Frequency\u003c\/strong\u003e: 208\/230V \/ 1-phase \/ 60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRunning Load Amps (RLA)\u003c\/strong\u003e: 7.8 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLocked Rotor Amps (LRA)\u003c\/strong\u003e: 47.5 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompressor Stages\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSound Power Level\u003c\/strong\u003e: 75 dB(A) per AHRI Standard 270-2008\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCabinet Height (A dimension)\u003c\/strong\u003e: 32.625 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCabinet Width (B dimension)\u003c\/strong\u003e: 29.75 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFactory Installed Start Components\u003c\/strong\u003e: No\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompressor Heat\u003c\/strong\u003e: No\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSound Blanket \/ Insulation\u003c\/strong\u003e: No\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Type\u003c\/strong\u003e: Split System Heat Pump\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Trane\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: A5HP5018A1000\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TRANE","offers":[{"title":"Default Title","offer_id":51217045913906,"sku":"A5HP5018A1000","price":2539.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/308795381.png?v=1780588574","url":"https:\/\/voomisupply.com\/products\/trane-a5hp5018a1000-runtru-1-5-ton-15-2-seer2-heat-pump","provider":"Voomi Supply","version":"1.0","type":"link"}