{"product_id":"trane-a5hp4048a1000-heat-pump-condenser-4-ton-r454b","title":"Trane A5HP4048A1000 Split System Heat Pump Condenser 4 Ton 14.3 SEER2 Single Stage R-454B Residential","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe Trane A5HP4048A1000 is a 4-ton single-stage split system heat pump condenser manufactured under the RunTru by Trane brand. Rated at 14.3 SEER2 and operating on R-454B refrigerant, this outdoor unit provides both heating and cooling for residential applications. It runs on 208\/230V single-phase 60 Hz power, draws 18.1 running load amps, and is factory charged for the outdoor unit plus 10 feet of connecting line with the smallest rated indoor evaporative coil match. Licensed HVAC technicians install this unit as the outdoor half of a matched split system paired with a compatible air handler or furnace coil.\u003c\/p\u003e\n\u003cp\u003eThis condenser is designed for residential split system installations where a single outdoor unit serves a whole-home heating and cooling load. It is AHRI rated only when matched with a TXV or EEV-equipped indoor coil or air handler, making proper indoor unit selection critical to achieving rated efficiency. The unit is listed to UL 60335-2-40 and is designed to operate at outdoor ambient temperatures up to 115 degrees F. A sound power level of 72 dB(A) A-weighted makes it suitable for standard residential lot setbacks. All phases of installation must comply with national, state, and local codes.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e4-ton nominal capacity delivering 48,000 BTU\/h for whole-home residential heating and cooling\u003c\/li\u003e\n  \u003cli\u003e14.3 SEER2 efficiency rating meets current minimum efficiency requirements\u003c\/li\u003e\n  \u003cli\u003eR-454B refrigerant — lower global warming potential than R-410A, forward-compliant with evolving regulations\u003c\/li\u003e\n  \u003cli\u003eSingle-stage operation simplifies controls integration and service diagnostics\u003c\/li\u003e\n  \u003cli\u003eFactory refrigerant charge sized for outdoor unit plus 10 feet of tested connecting line\u003c\/li\u003e\n  \u003cli\u003eAHRI certified when paired with compatible TXV or EEV indoor coil or air handler\u003c\/li\u003e\n  \u003cli\u003eUL 60335-2-40 listed for safety compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eAHRI rated only with TXV or EEV-equipped indoor coil and air handler matches. One documented system pairing includes the A5AHC007A1D30A air handler. Cooling capacities are matched with a wide selection of AHRI-certified air handlers and furnace coils. Verify AHRI certificate for the specific indoor-outdoor combination before installation.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed HVAC technician and must comply with all applicable national, state, and local codes. Disconnect and lock out all electrical power before servicing the unit. Because this system uses R-454B, technicians must use equipment rated and certified for mildly flammable A2L refrigerants and follow all applicable refrigerant handling regulations. Confirm line set length, indoor coil match, and TXV or EEV sizing against the AHRI certificate for the selected system combination before startup.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNominal Capacity\u003c\/strong\u003e: 4 Ton (48,000 BTU\/h)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEfficiency Rating\u003c\/strong\u003e: 14.3 SEER2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRefrigerant\u003c\/strong\u003e: R-454B\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStages\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage \/ Phase \/ Frequency\u003c\/strong\u003e: 208\/230V \/ 1-phase \/ 60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRunning Load Amps (RLA)\u003c\/strong\u003e: 18.1 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLocked Rotor Amps (LRA)\u003c\/strong\u003e: 95.0 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSound Power Level\u003c\/strong\u003e: 72 dB(A) A-weighted\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMax Ambient Operating Temperature\u003c\/strong\u003e: 115 degrees F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFactory Installed Start Components\u003c\/strong\u003e: No\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInsulation \/ Sound Blanket\u003c\/strong\u003e: No\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompressor Heat\u003c\/strong\u003e: No\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Height\u003c\/strong\u003e: 44.625 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Width\u003c\/strong\u003e: 34.25 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSafety Listing\u003c\/strong\u003e: UL 60335-2-40\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAHRI Rating Standard\u003c\/strong\u003e: Rated with TXV or EEV indoor coil match\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Trane (RunTru by Trane)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: A5HP4048A1000\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TRANE","offers":[{"title":"Default Title","offer_id":51195718172978,"sku":"A5HP4048A1000","price":2777.54,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/308796114.png?v=1780588963","url":"https:\/\/voomisupply.com\/products\/trane-a5hp4048a1000-heat-pump-condenser-4-ton-r454b","provider":"Voomi Supply","version":"1.0","type":"link"}