{"product_id":"trane-a5hp4036a1000-run-tru-3-ton-heat-pump-condenser-a5hp4036a1000","title":"Trane A5HP4036A1000 Single-stage Heat Pump Condenser 36000 Btu\/h 14.3 SEER2 3 Ton R-454B","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe Trane A5HP4036A1000 is a single-stage outdoor heat pump condensing unit from the RunTru by Trane product line, rated at 36,000 BTU\/h (3 tons) with a 14.3 SEER2 efficiency rating. Operating on R-454B refrigerant and powered by a 208\/230-volt, single-phase, 60 Hz supply, this unit delivers both heating and cooling in a single outdoor package. It is factory-charged with the system refrigerant required for the condensing unit, 10 feet of tested connecting line, and the smallest rated indoor evaporative coil match. Rated running load amps are 14.1, with a locked rotor amperage of 83.2. The unit is designed for residential split-system heat pump applications and is typically installed by licensed HVAC technicians.\u003c\/p\u003e\n\u003cp\u003eThis condensing unit is suited for residential split-system installations requiring year-round heating and cooling from a single outdoor unit. The A5HP4036A1000 is applicable to standard air conditioning and heat pump configurations and is designed to pair with a compatible indoor air handler or evaporator coil. The outdoor cabinet measures 32.625 inches tall, 34.25 inches wide, and 19.75 inches deep, making it suitable for standard residential pad or slab installations. Operating weight is 222 pounds. The unit is engineered to operate across a range of outdoor temperature conditions typical of residential service.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e36,000 BTU\/h (3-ton) single-stage cooling and heating capacity\u003c\/li\u003e\n  \u003cli\u003e14.3 SEER2 efficiency rating for compliance with current regional efficiency standards\u003c\/li\u003e\n  \u003cli\u003eR-454B refrigerant, the low-GWP replacement for R-410A\u003c\/li\u003e\n  \u003cli\u003e208\/230-volt, single-phase, 60 Hz operation with 14.1 RLA and 83.2 LRA\u003c\/li\u003e\n  \u003cli\u003eFactory-charged for condensing unit, 10 feet of line set, and minimum matched indoor coil\u003c\/li\u003e\n  \u003cli\u003ePSC blower motor with 27.5-inch blower diameter\u003c\/li\u003e\n  \u003cli\u003eA-weighted sound power level of 70 dB(A), rated per AHRI Standard 270-2008\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM-style replacement or new-installation condensing unit for residential split-system heat pump configurations requiring a 3-ton, single-stage outdoor unit matched to a compatible indoor evaporator coil or air handler.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed HVAC technician in accordance with local mechanical codes and the manufacturer installation documentation. Disconnect and lock out all electrical power before servicing or connecting the unit. The condensing unit must be mounted on a level pad or slab capable of supporting the operating weight. Refrigerant system work requires EPA Section 608 certification and must use equipment rated for R-454B.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCooling Capacity\u003c\/strong\u003e: 36,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEfficiency Rating\u003c\/strong\u003e: 14.3 SEER2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRefrigerant Type\u003c\/strong\u003e: R-454B\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage \/ Phase \/ Frequency\u003c\/strong\u003e: 208\/230 volts, 1-phase, 60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRunning Load Amps (RLA)\u003c\/strong\u003e: 14.1 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLocked Rotor Amps (LRA)\u003c\/strong\u003e: 83.2 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBlower Motor Type\u003c\/strong\u003e: PSC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBlower Diameter\u003c\/strong\u003e: 27.5 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStages\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSubcooling Charging Specification\u003c\/strong\u003e: 10 degrees F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSound Power Level\u003c\/strong\u003e: 70 dB(A) per AHRI Standard 270-2008\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Height\u003c\/strong\u003e: 32.625 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Width\u003c\/strong\u003e: 34.25 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Depth\u003c\/strong\u003e: 19.75 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Weight\u003c\/strong\u003e: 222 pounds\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFactory Installed Start Components\u003c\/strong\u003e: No\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInsulation \/ Sound Blanket\u003c\/strong\u003e: No\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompressor Heat\u003c\/strong\u003e: No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Trane\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: A5HP4036A1000\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TRANE","offers":[{"title":"Default Title","offer_id":51195721056562,"sku":"A5HP4036A1000","price":2475.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/308796111.png?v=1780589000","url":"https:\/\/voomisupply.com\/products\/trane-a5hp4036a1000-run-tru-3-ton-heat-pump-condenser-a5hp4036a1000","provider":"Voomi Supply","version":"1.0","type":"link"}