{"product_id":"square-d-xmlg006d23-analog-pressure-sensor-87-psi-24-vdc","title":"Square D XMLG006D23 Analog Pressure Sensor 87 Psi 24 Vdc","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe SQUARE D XMLG006D23 is an analog control circuit pressure sensor rated for 87 psi and 24 volts DC. It outputs a standard 4-20 mA signal, making it compatible with most industrial and HVAC control systems that accept analog current-loop inputs. The sensor uses a 1\/4-18 NPT male fluid connector and a 3-pin M12 male electrical connector. It measures 2.7 inches long and 0.9 inches in diameter, and weighs 0.29 pounds. Rated IP66 and IP67, the housing resists water ingress and dust intrusion. It is designed for installation by licensed HVAC technicians, electricians, or controls specialists working on pressure-sensing applications in control circuits.\u003c\/p\u003e\n\u003cp\u003eThis sensor is suited for residential and commercial applications where reliable pressure monitoring is required. It is rated for use with air, corrosive fluid, fresh water, and hydraulic oil, covering a wide range of system types including HVAC controls, fluid handling systems, and hydraulic equipment. Operating temperature range spans 5 degrees F to 185 degrees F, making it appropriate for installations in both cold and high-heat environments. Its shock-resistant and vibration-resistant construction suits installations in mechanically demanding locations such as rooftop units, compressor skids, or equipment rooms with sustained vibration.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e87 psi pressure range with 0.30 percent measurement accuracy\u003c\/li\u003e\n  \u003cli\u003e4-20 mA analog output signal for direct integration with control circuit inputs\u003c\/li\u003e\n  \u003cli\u003eIP66 and IP67 ingress protection rating for water and dust resistance\u003c\/li\u003e\n  \u003cli\u003eShock-resistant and vibration-resistant construction for demanding install environments\u003c\/li\u003e\n  \u003cli\u003eCompatible with air, corrosive fluid, fresh water, and hydraulic oil media\u003c\/li\u003e\n  \u003cli\u003eCertified to UL 508, CSA C22.2 No. 14, CE, EAC, and RoHS standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned for control circuit pressure-sensing applications using air, corrosive fluid, fresh water, or hydraulic oil as the process medium. Suitable for systems requiring a 4-20 mA analog signal input and a 1\/4-18 NPT male fluid connection with a 3-pin M12 male electrical interface.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation should be performed by a qualified electrician or licensed HVAC controls technician. De-energize the control circuit and depressurize the fluid system fully before making any connections. Apply appropriate thread sealant to the NPT fitting per IPC or IFGC guidelines and do not overtighten the fluid connector. Verify the control system input is configured for a 4-20 mA current-loop signal before powering up.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePressure Range\u003c\/strong\u003e: 87 psi\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 24 volts DC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput Signal\u003c\/strong\u003e: 4-20 mA analog\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e: 0.30 percent\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFluid Connector\u003c\/strong\u003e: 1\/4-18 NPT male\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical Connector\u003c\/strong\u003e: 3-pin M12 male\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIngress Protection\u003c\/strong\u003e: IP66, IP67\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOverall Length\u003c\/strong\u003e: 2.7 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOverall Diameter\u003c\/strong\u003e: 0.9 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.29 pounds\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimum Operating Temperature\u003c\/strong\u003e: 5 degrees F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Operating Temperature\u003c\/strong\u003e: 185 degrees F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatible Media\u003c\/strong\u003e: Air, Corrosive Fluid, Fresh Water, Hydraulic Oil\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertifications\u003c\/strong\u003e: UL 508, UL E164865, CSA C22.2 No. 14, CSA LR44087 Class 3211 03, CE, EAC, RoHS Compliant, EN\/IEC 60529, EN\/IEC 61326-2-3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: SQUARE D\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: XMLG006D23\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":51540528726322,"sku":"XMLG006D23","price":321.12,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/19c290511687aef11eb62cc367c37b5c.jpg?v=1785857576","url":"https:\/\/voomisupply.com\/products\/square-d-xmlg006d23-analog-pressure-sensor-87-psi-24-vdc","provider":"Voomi Supply","version":"1.0","type":"link"}