{"product_id":"square-d-qo2401021-miniature-circuit-breaker-40-amp","title":"Square D QO2401021 Miniature Circuit Breaker 40 Amp","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe Square D QO2401021 is a miniature circuit breaker designed for overcurrent protection and switching in AC and DC systems. This 2-pole breaker is rated at 40A and 120\/240VAC, with a 10kA breaking capacity and plug-in mounting. It features a trip-free toggle mechanism, quick make\/break action, and VisiTrip trip indication. Includes an AC shunt trip.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eProvides overcurrent protection and switching on AC and DC systems.\u003c\/li\u003e\n  \u003cli\u003eFeatures a trip-free toggle mechanism and quick make\/break action.\u003c\/li\u003e\n  \u003cli\u003eOffers VisiTrip trip indication for visual identification of tripped circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eThis Square D miniature circuit breaker provides reliable overcurrent protection with quick installation and clear trip indication.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: SQUARE D\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: QO2401021\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Mexico\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Miniature circuit-breaker\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Square D\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMPN\u003c\/strong\u003e: QO2401021\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCurrent\u003c\/strong\u003e: 40 Amp\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 120\/240 VAC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmperage\u003c\/strong\u003e: 40 Amp\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSub Brand\u003c\/strong\u003e: QO\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire Size\u003c\/strong\u003e: AWG 8...AWG 2 copper or aluminium\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplications\u003c\/strong\u003e: HACR rated\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Type\u003c\/strong\u003e: Plug-in\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTC Connection\u003c\/strong\u003e: Box lugs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertifications\u003c\/strong\u003e: CSA,UL Listed\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConductor Size\u003c\/strong\u003e: 8-2 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e: 2 Pole\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e: 5, 10 kAIC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLine Rated Current\u003c\/strong\u003e: 40 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCircuit Breaker Type\u003c\/strong\u003e: Standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShort Circuit Current\u003c\/strong\u003e: 10 kA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e: 120\/240 VAC at 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e: 40 Ampere\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e: 10 Kiloampere\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Type\u003c\/strong\u003e: Box Lug\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Plug On\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUsed On\u003c\/strong\u003e: QO Load Center, NQOD Panelboard, OEM Interior\/Speed-D Switchboard Distribution Panel\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApproval\u003c\/strong\u003e: UL, CSA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e: box lugs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e: 120\/240 V AC || 120 V AC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e: 10 kA 120\/240 V AC || 10 kA 120 V AC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAwg Gauge\u003c\/strong\u003e: AWG 8...AWG 2 copper or aluminium\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Certifications\u003c\/strong\u003e: UL Listed || CSA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: NQ\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplication\u003c\/strong\u003e: APPLIANCE, LIGHTING\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePoles\u003c\/strong\u003e: 2 POLE(S)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFrame Type\u003c\/strong\u003e: Q\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTripping Method\u003c\/strong\u003e: THERMAL MAGNETIC, COMMON TRIP\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire Range\u003c\/strong\u003e: 14 TO 8 AWG (ALUMINUM\/COPPER)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFeatures\u003c\/strong\u003e: WITH VISI-TRIP[R] INDICATOR, 120\/208\/240 VAC SHUNT TRIP\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFrequency\u003c\/strong\u003e: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Type\u003c\/strong\u003e: Thermal\/Magnetic Trip\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePhase\u003c\/strong\u003e: 1 ph\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnection\u003c\/strong\u003e: Box Lug Connection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandards\u003c\/strong\u003e: CSA C22.2 File No. 5|CSA Certified|Federal\/Specification W-C-375B\/GEN|HACR Rated|NEMA AB1|NOM\/ANCE Certified|PROP65: Cancer and reproductive harm - www.P65warnings.ca.gov|RoHS Compliant|UL File No. 489 File No. E84967|UL Listed\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAC Voltage Rating\u003c\/strong\u003e: 120\/240V AC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDC Voltage Rating\u003c\/strong\u003e: 48V DC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCircuit Breaker Actuator\u003c\/strong\u003e: Paddle\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCircuit Breaker Mounting Style\u003c\/strong\u003e: Plug In\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatible Panelboard\/Load Center Series\u003c\/strong\u003e: QO\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMax. AIR Rating\u003c\/strong\u003e: 10kA at 120\/240V AC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFor Use With\u003c\/strong\u003e: QO Load Centers and NQ Panelboards\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Connection\u003c\/strong\u003e: Lug\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFrame Size\u003c\/strong\u003e: 100A\/QO\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMin. Wire Size\u003c\/strong\u003e: 8 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMax. Wire Size\u003c\/strong\u003e: 8 AWG\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":50996321255730,"sku":"QO2401021","price":206.59,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/297715989.jpg?v=1778776862","url":"https:\/\/voomisupply.com\/products\/square-d-qo2401021-miniature-circuit-breaker-40-amp","provider":"Voomi Supply","version":"1.0","type":"link"}