{"product_id":"square-d-qo130gfi-qo-mini-circuit-breaker-plug-in-30a-120-vac-single-pole","title":"Square D QO130GFI QO Mini Circuit Breaker, Plug-In, 30A, 120 VAC, Single-Pole","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe Square D QO130GFI is a QO mini circuit breaker designed for overcurrent protection and switching on AC and DC systems. This single-pole, plug-in mounted breaker is rated at 30A and 120 VAC, with a 10kA breaking capacity. It features a trip-free toggle mechanism, VisiTrip trip indication, and includes 6mA ground fault protection with a pigtail.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eProvides overcurrent protection and switching on AC and DC systems\u003c\/li\u003e\n  \u003cli\u003eFeatures a trip-free toggle mechanism with quick make, quick break action\u003c\/li\u003e\n  \u003cli\u003eIncludes 6mA ground fault protection with pigtail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eThis Square D QO mini circuit breaker offers reliable overcurrent and ground fault protection for residential and commercial electrical systems. UL Listed and CSA certified.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: SQUARE D\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: QO130GFI\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Mexico\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Ground Fault\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDepth\u003c\/strong\u003e: 2.91 Inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWidth\u003c\/strong\u003e: 0.75 Inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeight\u003c\/strong\u003e: 4.13 Inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaterial\u003c\/strong\u003e: Thermoplastic\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard\u003c\/strong\u003e: UL Listed, CSA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e: 120 VAC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e: 30 Amperes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber Of Poles\u003c\/strong\u003e: Single-Pole\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e: 10 kAIC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCircuit Breaker Type\u003c\/strong\u003e: Ground fault protecting class A 6 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRange Of Product\u003c\/strong\u003e: QO\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Or Component Type\u003c\/strong\u003e: miniature circuit-breaker\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Mode\u003c\/strong\u003e: Plug-in\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePoles Description\u003c\/strong\u003e: 1P\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e: pressure plate\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLine Rated Current\u003c\/strong\u003e: 30 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e: 120 V AC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e: 10 kA 120 V AC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAwg Gauge\u003c\/strong\u003e: AWG 14...AWG 8 copper || AWG 12...AWG 8 aluminium\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTightening Torque\u003c\/strong\u003e: 4-4 N.m || 4.6-4.6 N.m 4-20 mm² (AWG 12...AWG 4)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber Of Spaces Required\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Certifications\u003c\/strong\u003e: UL Listed || CSA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmbient Air Temperature For Operation\u003c\/strong\u003e: 40 °C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCurrent\u003c\/strong\u003e: 30 Amp\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 120 Volt\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmperage\u003c\/strong\u003e: 30 Amp\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSub Brand\u003c\/strong\u003e: QO\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire Size\u003c\/strong\u003e: AWG 14...AWG 8 copper;AWG 12...AWG 8 aluminium\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplications\u003c\/strong\u003e: Not rated\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTC Connection\u003c\/strong\u003e: Pressure plate\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertifications\u003c\/strong\u003e: CSA,UL Listed\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConductor Size\u003c\/strong\u003e: 12-8 AWG (AL)\/14-8 AWG (CU)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShort Circuit Current\u003c\/strong\u003e: 10 kA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Plug-On\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Type\u003c\/strong\u003e: Pressure Plate\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUsed On\u003c\/strong\u003e: QO Loadcenter, NQOD Panelboard, OEM Interior\/Speed-D Switchboard Distribution Panel\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApproval\u003c\/strong\u003e: UL, CSA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplication\u003c\/strong\u003e: Provides Overload and Short Circuit Protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: QO\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart Number\u003c\/strong\u003e: QO130GFI\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePoles\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePhase\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAIC Rating\u003c\/strong\u003e: 10kA @ 120VAC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSpecial Classification\u003c\/strong\u003e: GFCI\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Style\u003c\/strong\u003e: Plug-On\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFor Use With\u003c\/strong\u003e: QO Load Centers, NQ Panelboards, NQOD Panelboards\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Technology\u003c\/strong\u003e: Thermal Magnetic\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Function Code\u003c\/strong\u003e: LIG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Function\u003c\/strong\u003e: Long-Time, Instantaneous, Ground Fault\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Adjustability\u003c\/strong\u003e: Fixed Thermal, Fixed Magnetic\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire Gauge\u003c\/strong\u003e: 14-8 AWG (Cu), 12-8 AWG (Al)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMax Wire\u003c\/strong\u003e: 8 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMin Wire\u003c\/strong\u003e: 14 AWG (Cu), 12 AWG (Al)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAvailable Options\u003c\/strong\u003e: Shunt Trip, Auxiliary Switch, Alarm Switch, Padlock Attachment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAccessories\u003c\/strong\u003e: Pigtail Neutral\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandards\u003c\/strong\u003e: CSA C22.2 No. 144, UL 489, UL 943, HACR Rated\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemp Rating\u003c\/strong\u003e: 40C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConstruction Features\u003c\/strong\u003e: Visual Trip Indicator, Mercury Free\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eItem\u003c\/strong\u003e: Miniature Circuit Breaker\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAC Voltage Rating\u003c\/strong\u003e: 120V AC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDC Voltage Rating\u003c\/strong\u003e: 48V DC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCircuit Breaker Actuator\u003c\/strong\u003e: Paddle\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatible Panelboard\/Load Center Series\u003c\/strong\u003e: NQ, QO\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Sensitivity\u003c\/strong\u003e: 6 Milliampere\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFrame\u003c\/strong\u003e: QO\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":51382335832370,"sku":"QO130GFI","price":172.02,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/312635053.png?v=1782562750","url":"https:\/\/voomisupply.com\/products\/square-d-qo130gfi-qo-mini-circuit-breaker-plug-in-30a-120-vac-single-pole","provider":"Voomi Supply","version":"1.0","type":"link"}