{"product_id":"square-d-edb34080-miniature-circuit-breaker-80-amp-3-pole","title":"Square D EDB34080 miniature circuit breaker 80 amp 3 pole","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe Square D EDB34080 is an E-Frame breaker designed for lighting panelboard circuits. This 3-pole, 80 Amp circuit breaker operates at 480Y\/277 VAC and offers overload and short circuit protection. It features a thermal-magnetic trip unit and a signal indicator. The EDB34080 is HACR rated and calibrated for 40 degrees C.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eE-Frame Breaker\u003c\/li\u003e\n  \u003cli\u003eSuperior overload and short circuit protection\u003c\/li\u003e\n  \u003cli\u003eThermal-magnetic trip unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eProvides reliable circuit protection with thermal-magnetic trip and trip indication. Ideal for Square D NF Panelboards.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: SQUARE D\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: EDB34080\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: United States\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: MOLDED CASE CIRCUIT BREAKER\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Square D\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDepth\u003c\/strong\u003e: 4.05 Inch\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFrame\u003c\/strong\u003e: E-FRAME\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWidth\u003c\/strong\u003e: 2.94 in\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeight\u003c\/strong\u003e: 5.66 Inch\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLength\u003c\/strong\u003e: 4.05 Inch\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 277\/480 VAC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmperage\u003c\/strong\u003e: 80 Amp\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSub Brand\u003c\/strong\u003e: E FRAME\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Type\u003c\/strong\u003e: THERMAL-MAGNETIC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Range\u003c\/strong\u003e: HOLD: 1000A - TRIP: 2300A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Type\u003c\/strong\u003e: E-Frame\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct UPC\u003c\/strong\u003e: 78590187536\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e12-Digit UPC\u003c\/strong\u003e: 785901875369\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplications\u003c\/strong\u003e: PROVIDES OVERLOAD AND SHORT CIRCUIT PROTECTION\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Type\u003c\/strong\u003e: Bolt-On\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTC Connection\u003c\/strong\u003e: LUGS #12 TO #2\/0 AWG(AL) - #14 TO #2\/0 AWG(CU)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertifications\u003c\/strong\u003e: CULus\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e: 3 Pole\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e: 18 kAIC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Spaces\u003c\/strong\u003e: 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLine Rated Current\u003c\/strong\u003e: 80 Amp\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 40 Adegrees C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Schneider Electric\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUPC\u003c\/strong\u003e: 785901875369\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGTIN\u003c\/strong\u003e: 00785901875369\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Wire Size\u003c\/strong\u003e: 12 to 2\/0 AWG (Aluminum), 14 to 2\/0 AWG (Copper)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInstallation\u003c\/strong\u003e: Bolt-On\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplication\u003c\/strong\u003e: Lighting\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUsed On\u003c\/strong\u003e: Class 515 NF Series Panelboard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApproval\u003c\/strong\u003e: UL, CSA, NOM 117\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTripping Method\u003c\/strong\u003e: Thermal Magnetic\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePoles\u003c\/strong\u003e: 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e: 120\/240\/277 VAC at 50\/60 Hz, 480 VAC Star\/277 VAC at 50\/60 Hz (UL\/CSA), 240 VAC at 50\/60 Hz (IEC)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e: 80 Ampere\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterrupting Rating\u003c\/strong\u003e: 25 Kiloampere at 120\/240 VAC, 18 Kiloampere at 480 VAC Star\/277 VAC or 277 VAC (UL\/CSA)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Setting\u003c\/strong\u003e: 1000 to 2300 Ampere\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHACR Rated\u003c\/strong\u003e: Yes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHold Current\u003c\/strong\u003e: 1000A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Current\u003c\/strong\u003e: 2300A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCalibration Temperature\u003c\/strong\u003e: 40 degrees C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRange Of Product\u003c\/strong\u003e: 125 A Frame EDB-EGB-EJB\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Or Component Type\u003c\/strong\u003e: miniature circuit-breaker\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Unit Rating\u003c\/strong\u003e: 875 Amp\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDevice Short Name\u003c\/strong\u003e: EDB\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHolding Current\u003c\/strong\u003e: 270 Amp\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity Code\u003c\/strong\u003e: D\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Destination\u003c\/strong\u003e: Square D NF Panelboard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e: Aluminum Lugs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber Of Spaces Required\u003c\/strong\u003e: 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Mode\u003c\/strong\u003e: Bolt-On\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProtection Type\u003c\/strong\u003e: Short-Circuit \/ Overload\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLocal Signalling\u003c\/strong\u003e: trip indicator\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAwg Gauge\u003c\/strong\u003e: AWG 12...AWG 2\/0 aluminium || AWG 14...AWG 2\/0 copper\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e: 18 kA 277 V AC || 25 kA 240 V AC || 18 kA 480Y\/277 V AC || 25 kA 120 V AC || 25 kA 120\/240 V AC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Unit Technology\u003c\/strong\u003e: thermal-magnetic\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e: 480Y\/277 V AC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Certifications\u003c\/strong\u003e: cULus\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmbient Air Temperature For Operation\u003c\/strong\u003e: 40 °C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmp\u003c\/strong\u003e: 80\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVolt\u003c\/strong\u003e: 480\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePhase\u003c\/strong\u003e: 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Molded Case \/ 3-Pole\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnection\u003c\/strong\u003e: Bolt-On\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunctions\u003c\/strong\u003e: LI - Long-Time and Instantaneous\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAIC Ratings\u003c\/strong\u003e: 18kA@480V | 18kA@277V | 25kA@240V | 25kA@120V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Operating Voltage\u003c\/strong\u003e: 480Y\/277 V AC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHolding Current - Metric\u003c\/strong\u003e: 1000 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLine Rated Current - Metric\u003c\/strong\u003e: 80 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFamily\u003c\/strong\u003e: EDB Series\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProtection\u003c\/strong\u003e: Thermal Magnetic\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLocal Signaling\u003c\/strong\u003e: Trip Indicator\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCircuit Breaker Application\u003c\/strong\u003e: HID-Rated \/ HACR-Rated\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAWG Gauge\u003c\/strong\u003e: AWG 12...AWG 6 Aluminum | AWG 14...AWG 6 Copper\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":50971535966514,"sku":"EDB34080","price":1142.76,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/296439007.png?v=1778777200","url":"https:\/\/voomisupply.com\/products\/square-d-edb34080-miniature-circuit-breaker-80-amp-3-pole","provider":"Voomi Supply","version":"1.0","type":"link"}