{"product_id":"square-d-9012gar5-pressure-switch-3-150-psig-nema-7-9","title":"Square D 9012GAR5 Pressure Switch 3-150 Psig Nema 7 9","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\u003cp\u003eThe SQUARE D 9012GAR5 is an electromechanical pressure and level switch designed for industrial and commercial fluid-control applications. It operates across a pressure range of 3 to 150 psig with an adjustable differential, making it adaptable to a wide variety of system setpoints. The switch uses an SPDT-DB contact form with screw terminal connections and supports multiple voltage configurations: 120 VAC, 240 VAC, 125 VDC, and 250 VDC. Rated at 6 amps, it is built to NEMA 7 and NEMA 9 standards for use in hazardous locations. Licensed electricians and instrumentation technicians are the primary installers of this device.\u003c\/p\u003e\u003cp\u003eThis pressure switch is suited for hydraulic systems and pneumatic systems in both industrial and commercial environments. Its vibration-resistant construction makes it appropriate for installations where mechanical shock or continuous vibration is present, such as compressor skids, pump stations, or fluid-power panels. The 1\/4-inch fluid connection port and 1\/2-inch conduit connector accommodate standard piping and conduit configurations common in these applications. It is typically installed as a control or safety interlock device within pressure-sensing circuits.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003ePressure range: 3 to 150 psig with adjustable differential (9 to 35 psi differential range)\u003c\/li\u003e\n\u003cli\u003eSPDT-DB contact form with screw terminal wiring for straightforward field connections\u003c\/li\u003e\n\u003cli\u003eNEMA 7 and NEMA 9 rated for hazardous location use\u003c\/li\u003e\n\u003cli\u003eMulti-voltage support: 120 VAC, 240 VAC, 125 VDC, 250 VDC at 6 amps\u003c\/li\u003e\n\u003cli\u003eVibration-resistant design per IEC 68-2-6 and IEC 58-2-27\u003c\/li\u003e\n\u003cli\u003eCompliant with UL 508, CSA C22.2 No. 14, CE, and RoHS standards\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\u003cp\u003eDesigned for use with hydraulic systems and pneumatic systems as stated by the manufacturer. Verify system pressure range and voltage requirements against your application before installation.\u003c\/p\u003e\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\u003cp\u003eInstallation should be performed by a licensed electrician or qualified instrumentation technician in accordance with the NEC and any applicable local codes. De-energize the circuit and depressurize the connected system completely before making any fluid or electrical connections. The 1\/2-inch conduit entry and screw terminals must be properly sealed and torqued per conduit fitting manufacturer specifications to maintain the NEMA 7 and NEMA 9 hazardous-location ratings. Do not exceed the rated pressure or amperage limits stated on the device nameplate.\u003c\/p\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Range\u003c\/strong\u003e: 3 to 150 psig\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Differential Pressure\u003c\/strong\u003e: 9 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Differential Pressure\u003c\/strong\u003e: 35 psi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDifferential Pressure Type\u003c\/strong\u003e: Adjustable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 120 VAC, 240 VAC, 125 VDC, 250 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage\u003c\/strong\u003e: 6 amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Form\u003c\/strong\u003e: SPDT-DB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Type\u003c\/strong\u003e: Screw\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluid Connection\u003c\/strong\u003e: 1\/4 inch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit Connection\u003c\/strong\u003e: 1\/2 inch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNEMA Rating\u003c\/strong\u003e: 7 and 9\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance Features\u003c\/strong\u003e: Vibration-Resistant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards Met\u003c\/strong\u003e: UL 508, CSA C22.2 No. 14, CE, IEC 58-2-27, IEC 68-2-6, RoHS Compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight\u003c\/strong\u003e: 12 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth\u003c\/strong\u003e: 12 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength\u003c\/strong\u003e: 6.4 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 10.27 pounds\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandard Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: SQUARE D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 9012GAR5\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":51542021767474,"sku":"9012GAR5","price":1943.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/e0424cc0f418a3a3e597263b14d125e7.jpg?v=1785889842","url":"https:\/\/voomisupply.com\/products\/square-d-9012gar5-pressure-switch-3-150-psig-nema-7-9","provider":"Voomi Supply","version":"1.0","type":"link"}