{"product_id":"southwire-20502101-thhn-thwn-2-awg-95a-building-wire","title":"Southwire 20502101 Thhn Thwn 2 Awg 95A Building Wire","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe SOUTHWIRE 20502101 is a 2 AWG stranded copper THHN\/THWN building wire rated for 95 amps at 600 volts. It features a thermoplastic insulation layer with a nylon jacket and is constructed with 19 strands for flexibility during pull-through in conduit. The maximum operating temperature is 194 degrees F. Electricians use this wire for branch circuit wiring, feeder runs, and general-purpose power distribution in commercial and residential construction. The single-conductor configuration and nylon jacket make it well suited for conduit installations where resistance to abrasion, heat, moisture, and oil exposure is required.\u003c\/p\u003e\n\u003cp\u003eThis wire is appropriate for use in dry, damp, and wet locations in both residential and commercial electrical systems. Common applications include service entrance feeders, panel-to-subpanel runs, motor branch circuits, and general-purpose branch wiring pulled through metallic or non-metallic conduit. The black jacket color is standard for use as an ungrounded (hot) conductor in single- and three-phase systems. It is sold in 1-foot increments with a 250-foot minimum cut length from a 500-foot coil.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e2 AWG stranded copper conductor with 19-strand construction for improved flexibility\u003c\/li\u003e\n  \u003cli\u003eRated 95 amps at 600 volts for heavy branch circuit and feeder applications\u003c\/li\u003e\n  \u003cli\u003eThermoplastic insulation with nylon jacket for durability in conduit pulls\u003c\/li\u003e\n  \u003cli\u003eMaximum operating temperature of 194 degrees F\u003c\/li\u003e\n  \u003cli\u003eResistant to abrasion, gasoline, heat, moisture, oil, and sunlight\u003c\/li\u003e\n  \u003cli\u003eMeets UL 83, UL 1063 (MTW), CSA, RoHS, and Federal Specification A-A-59544\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned for use as a general-purpose THHN\/THWN stranded building wire in conduit systems rated up to 600 volts in residential and commercial electrical installations.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed electrician in accordance with NFPA 70 (National Electrical Code) and applicable local codes. De-energize and lock out the circuit before making any terminations or splices. Use appropriate conduit fill calculations per NEC Article 310 to confirm conduit sizing before pulling wire. Avoid sharp bends and edges during pulls to protect the nylon jacket and maintain insulation integrity.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire Size\u003c\/strong\u003e: 2 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmperage\u003c\/strong\u003e: 95 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e: 600 volts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConductor Type\u003c\/strong\u003e: THHN\/THWN\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCore Type\u003c\/strong\u003e: Stranded\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Strands\u003c\/strong\u003e: 19\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire Material\u003c\/strong\u003e: Copper\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInsulation Material\u003c\/strong\u003e: Thermoplastic\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJacket Material\u003c\/strong\u003e: Nylon\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJacket Color\u003c\/strong\u003e: Black\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Conductors\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Operating Temperature\u003c\/strong\u003e: 194 degrees F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResistance Features\u003c\/strong\u003e: Abrasion, Gasoline, Heat, Moisture, Oil, Sunlight\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimum Order Quantity\u003c\/strong\u003e: 250 feet\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTotal Coil Length\u003c\/strong\u003e: 500 feet\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.35 pounds\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandards\u003c\/strong\u003e: UL 83, UL 1063 (MTW), UL Listed, CSA, RoHS Compliant, Federal Specification A-A-59544, ASTM Specifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: SOUTHWIRE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 20502101\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SOUTHWIRE","offers":[{"title":"Default Title","offer_id":51539072352562,"sku":"20502101","price":2864.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/45bd4b948f5a4cf788e1978852aef8c5.jpg?v=1785834367","url":"https:\/\/voomisupply.com\/products\/southwire-20502101-thhn-thwn-2-awg-95a-building-wire","provider":"Voomi Supply","version":"1.0","type":"link"}