{"product_id":"southwire-11590701-thhn-thwn-12-awg-20a-500ft-solid-copper-wire","title":"Southwire 11590701 Thhn Thwn 12 Awg 20A 500ft Solid Copper Wire","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe SOUTHWIRE 11590701 is a 12 AWG solid copper THHN\/THWN building wire rated for 20 amps at 600 volts. This 500-foot spool features a blue nylon-jacketed, thermoplastic-insulated single conductor designed for branch circuit and general wiring applications in commercial and residential construction. The solid core construction and dual THHN\/THWN rating make it suitable for both dry and wet locations. Licensed electricians use this wire for standard 20-amp branch circuits in conduit runs throughout walls, ceilings, and electrical panels.\u003c\/p\u003e\n\u003cp\u003eThis wire is suited for use in commercial buildings, residential new construction, and renovation projects where code-compliant branch circuit wiring is required. The blue jacket color supports color-coded circuit identification, which is common practice in multi-circuit panel installations. It is intended for use in conduit or raceway systems and meets the requirements for most 20-amp dedicated and general-purpose circuits wired under the National Electrical Code.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eDual-rated THHN\/THWN insulation suitable for dry and wet locations\u003c\/li\u003e\n  \u003cli\u003eSolid 12 AWG copper conductor rated for 20 amps at 600 volts\u003c\/li\u003e\n  \u003cli\u003eBlue nylon jacket supports color-coded circuit identification\u003c\/li\u003e\n  \u003cli\u003eMaximum operating temperature of 194 degrees F\u003c\/li\u003e\n  \u003cli\u003eResistant to abrasion, gasoline, heat, moisture, and oil\u003c\/li\u003e\n  \u003cli\u003e500-foot spool minimizes splicing on long conduit runs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as a standard THHN\/THWN single-conductor building wire for use in conduit or raceway systems on 20-amp branch circuits in residential and commercial electrical installations.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed electrician in accordance with the National Electrical Code and applicable local codes. Always de-energize the circuit and verify zero voltage at the panel before pulling or terminating wire. This wire is rated for use in conduit and raceways and should not be used as a substitute for cable assemblies in applications requiring armored or sheathed wiring. Observe conduit fill limits per NEC Article 358 or the applicable raceway article when sizing conduit for this conductor.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire Gauge\u003c\/strong\u003e: 12 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e: 20 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e: 600 volts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLength\u003c\/strong\u003e: 500 feet\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConductor Type\u003c\/strong\u003e: Solid\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Conductors\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Strands\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConductor Material\u003c\/strong\u003e: Copper\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInsulation Material\u003c\/strong\u003e: Thermoplastic\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJacket Material\u003c\/strong\u003e: Nylon\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eJacket Color\u003c\/strong\u003e: Blue\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Operating Temperature\u003c\/strong\u003e: 194 degrees F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResistance Features\u003c\/strong\u003e: Abrasion, Gasoline, Heat, Moisture, Oil\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 12.5 pounds\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertifications\u003c\/strong\u003e: UL Listed, UL 83, UL 1063 (MTW), CSA, RoHS Compliant, ASTM Specifications, Federal Specification A-A-59544\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: SOUTHWIRE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 11590701\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SOUTHWIRE","offers":[{"title":"Default Title","offer_id":51540272939314,"sku":"11590701","price":171.35,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/8fb893940298e28b1d584c33429f59e4.jpg?v=1785850898","url":"https:\/\/voomisupply.com\/products\/southwire-11590701-thhn-thwn-12-awg-20a-500ft-solid-copper-wire","provider":"Voomi Supply","version":"1.0","type":"link"}