{"product_id":"source-1-s8610u3009-intermittent-pilot-control-universal-intermittent-pilot-control-module","title":"Source 1 S8610U3009 Intermittent Pilot Control Universal Intermittent Pilot Control Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe SOURCE 1 S8610U3009 universal intermittent pilot control module provides electronic control of most intermittent pilot ignition systems used on gas-fired furnaces, boilers, and other heating appliances. It has continuous retry trial time, configurable lockout timing of 15 or 90 seconds and configurable prepurge of 30 seconds or no prepurge.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eProvides ignition sequence, flame monitoring and safety shutoff for intermittent pilot central furnaces and heating appliances\u003c\/li\u003e\n  \u003cli\u003eProvides 100 percent pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for ignition is repeated. Ignition trial\/delay sequence is repeated until the appliance lights or call for heat is removed\u003c\/li\u003e\n  \u003cli\u003eFor use with Natural or LP gas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eThe S8610U3009 module is for use in single rod or dual rod\/remote sense applications. Includes spark cable adapters to allow field replacement of both Honeywell and competitive controls without replacing existing spark cable.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: SOURCE 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: S8610U3009\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgnition System Type\u003c\/strong\u003e: Intermittent Pilot\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgnition Sequence\u003c\/strong\u003e: Continuous Retry\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTypical Gas Control\u003c\/strong\u003e: VR8204, VR8304\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType of Gas\u003c\/strong\u003e: Natural or LP\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlame Sense\u003c\/strong\u003e: Two Rod, Single Rod\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgnition Source\u003c\/strong\u003e: Internal high voltage spark generator\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrePurge\u003c\/strong\u003e: Configurable to 30 sec or no prepurge\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgnition Trials To Lockout\u003c\/strong\u003e: continuous retry\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLockout Timing\u003c\/strong\u003e: Configurable to 15 seconds or 90 seconds\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgnition Trial Time\u003c\/strong\u003e: 15 or 90 seconds\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Valve Load\u003c\/strong\u003e: 1 A Pilot, 2A Main @ 165 °F, 1 A Pilot, 1A Main @ 175 °F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTypical Ignition Hardware\u003c\/strong\u003e: Q345, Q3451, Q3452\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e: 3-15\/16\" high x 5-7\/16\" wide x 2-5\/8\" deep\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical Ratings\u003c\/strong\u003e: 24 Vac\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFrequency\u003c\/strong\u003e: 50 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Ambient Temperature\u003c\/strong\u003e: 165 °F, 74 °C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApprovals and Standards\u003c\/strong\u003e: CSA: Design Certified\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIncludes\u003c\/strong\u003e: Spark cable adapters to allow field replacement of both Resideo and competitive controls without replacing existing spark cable\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBetween Trial Time (sec)\u003c\/strong\u003e: 5 minute delay after failed trial for ignition\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlame Failure Response Time\u003c\/strong\u003e: 2 seconds maximum\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgnition Type\u003c\/strong\u003e: Intermittent Pilot\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplication\u003c\/strong\u003e: Intermittent Pilot\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Features\u003c\/strong\u003e: For use with natural or LP gas, For use in single rod or dual rod or remote sense applications, Configurable to 30 sec, Universal Pilot Ignition Module, Intermittent, 24 V AC, Replaces over 400 White-Rodgers, Robertshaw and Honeywell intermittent pilot ignition modules, Provides ignition sequencing, flame monitoring and safety shutoff for intermittent pilot warm air furnaces and heating appliances, Provides 100 percent pilot gas shutoff if pilot fails to light after 6 min delay., No prepurge\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType of Fuel\u003c\/strong\u003e: Natural Gas, LPG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePilot Type\u003c\/strong\u003e: Intermittent\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgnition Between Trail Time\u003c\/strong\u003e: 5 minute delay after failed trial for ignition.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Ignition Trials to Lockout\u003c\/strong\u003e: 0\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEarly Spark Termination\u003c\/strong\u003e: Yes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAuto Reset Delay Timing\u003c\/strong\u003e: 1 min\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermostat Anticipator Rating\u003c\/strong\u003e: 0.2 A plus pilot valve rating plus main valve rating\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCurrent Draw\u003c\/strong\u003e: 1 A Pilot Valve|2 A Main Valve\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Consumption\u003c\/strong\u003e: 2 VA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLoad Relay Rating\u003c\/strong\u003e: 24 V AC (Amps) 1 A  Pilot, 2 A Main at 165 °F, 1A Pilot, 1A Main at 175 °F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgniter-Sensor Rod\u003c\/strong\u003e: Dual, Single\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Depth\u003c\/strong\u003e: 2.63 in, 67mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply Frequency\u003c\/strong\u003e: 60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 24 V AC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatible With\u003c\/strong\u003e: Intermittent pilot warm air furnaces and heating appliances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFor Use With\u003c\/strong\u003e: Q345, Q348, Q362, Q373, Q381, Q179C, Q354,  Q345, Q348,  Q362, Q373, Q381\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDo Not Use With\u003c\/strong\u003e: Do Not Use the 24 V Terminal on S8610U\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Height\u003c\/strong\u003e: 3.94 in, 100 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Width\u003c\/strong\u003e: 5.44 in, 138 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmbient Operating Temperature (Min)\u003c\/strong\u003e: -40 °F, -40 °C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSuperseded By\u003c\/strong\u003e: HW-S8610U3009\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Source 1\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"SOURCE 1","offers":[{"title":"Default Title","offer_id":51149580173618,"sku":"S8610U3009","price":428.7,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/305973547.jpg?v=1778597685","url":"https:\/\/voomisupply.com\/products\/source-1-s8610u3009-intermittent-pilot-control-universal-intermittent-pilot-control-module","provider":"Voomi Supply","version":"1.0","type":"link"}