{"product_id":"siemens-3va5180-6ec31-0aa0-breaker-molded-case-80a-3p","title":"Siemens 3VA5180-6EC31-0AA0 Breaker, Molded Case, 80A, 3P","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe SIEMENS 3VA5180-6EC31-0AA0 is a molded case circuit breaker from the 3VA5 series, designed for low-voltage and medium-voltage power distribution. Meeting IEC 60947-2 and UL489 standards, this 3-pole breaker is suitable for global use, protecting cables, electrical loads, and industrial plants. It features a thermal\/magnetic trip unit and a 65kA interrupt rating at 480V.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSuitable for AC\/DC applications.\u003c\/li\u003e\n  \u003cli\u003eCompact design with modular and easy to fit internal accessories.\u003c\/li\u003e\n  \u003cli\u003eMeets IEC 60947-2 and UL489 standards for global use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eThis Siemens breaker offers reliable circuit protection with a compact design and modular accessories, suitable for various applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: SIEMENS\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 3VA5180-6EC31-0AA0\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Czech Republic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: SIEMENS\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 3VA5180-6EC31-0AA0\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e: 80 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SENTRON\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e: 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Thermal\/Magnetic\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 690 VAC\/500 VDC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFrequency\u003c\/strong\u003e: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e: 64 kA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Type\u003c\/strong\u003e: Thermal\/Magnetic Trip\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: IP40\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Fixed Mounting\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature\u003c\/strong\u003e: -25 to 70 deg C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMain function\u003c\/strong\u003e: Moulded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSub-range name\u003c\/strong\u003e: 3VA UL 489 breakers series\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNetwork frequency\u003c\/strong\u003e: 0-400 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunctions\u003c\/strong\u003e: Moulded \/ Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated current\u003c\/strong\u003e: 80A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip current rating\u003c\/strong\u003e: 80 AT\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFrame current rating\u003c\/strong\u003e: 125 AF\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated voltage (AC)\u003c\/strong\u003e: 600Y\/347Vac\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated impulse voltage (Uimp)\u003c\/strong\u003e: 8 kV\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShort circuit breaking rating\u003c\/strong\u003e: Class \"H\"\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e100kA (240Vac; UL489)\u003c\/strong\u003e: 100kA (240Vac; UL489)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e65kA (480Y\/277Vac; UL489)\u003c\/strong\u003e: 65kA (480Y\/277Vac; UL489)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e65kA (480Vac; UL489)\u003c\/strong\u003e: 65kA (480Vac; UL489)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e25kA (600Y\/347Vac; UL489)\u003c\/strong\u003e: 25kA (600Y\/347Vac; UL489)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e100kA (250Vdc; UL)\u003c\/strong\u003e: 100kA (250Vdc; UL)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e100kA (500Vdc; UL)\u003c\/strong\u003e: 100kA (500Vdc; UL)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTM230 FTAM\u003c\/strong\u003e: TM230 FTAM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProtection functions\u003c\/strong\u003e: Thermal protection (Overload)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMagnetic protection (Short-circuit)\u003c\/strong\u003e: Magnetic protection (Short-circuit)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProtection settings\u003c\/strong\u003e: Thermal protection (Overload) -- tripping threshold fixed at 80A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMagnetic protection (Short-circuit) -- short-circuit pickup current adjustable 400A...800A\u003c\/strong\u003e: Magnetic protection (Short-circuit) -- short-circuit pickup current adjustable 400A...800A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting mode\u003c\/strong\u003e: Surface or DIN rail\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical durability (with load)\u003c\/strong\u003e: 8000 operations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMechanical durability (at no load)\u003c\/strong\u003e: 15000 operations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOrder code \/ Manufacturer SKU\u003c\/strong\u003e: 3VA5180-6EC31-0AA0\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompliant with standard(s)\u003c\/strong\u003e: IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA22.2\u003c\/strong\u003e: CSA22.2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL489\u003c\/strong\u003e: UL489\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: Circuit Protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCircuit Breakers\u003c\/strong\u003e: Circuit Breakers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart Status\u003c\/strong\u003e: Active\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Type\u003c\/strong\u003e: DIN Rail\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage Rating - AC\u003c\/strong\u003e: 690 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eActuator Type\u003c\/strong\u003e: Lever\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIllumination\u003c\/strong\u003e: None\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApproval Agency\u003c\/strong\u003e: CCC, CE, CSA, EAC, UL489, VDE\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"SIEMENS","offers":[{"title":"Default Title","offer_id":50996340293938,"sku":"3VA5180-6EC31-0AA0","price":1158.19,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/297719910.jpg?v=1774016363","url":"https:\/\/voomisupply.com\/products\/siemens-3va5180-6ec31-0aa0-breaker-molded-case-80a-3p","provider":"Voomi Supply","version":"1.0","type":"link"}