{"product_id":"siemens-3rv20314bb10-circuit-breaker-for-motor-protection-s2-class-20-14-20a-screw-3rv2-series","title":"Siemens 3RV20314BB10 Circuit Breaker for Motor Protection S2 Class 20 14-20A Screw 3RV2 Series","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe SIEMENS 3RV20314BB10 is a circuit breaker for motor protection S2 Class 20 14-20A Screw 3RV2 Series. It features a-release 14...20a and n-release 260a. It is designed with a screw terminal and standard breaking capacity. Suitable for operation in IT systems (IT networks).\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMinimization of energy losses through optimization of the bimetal trip units\u003c\/li\u003e\n  \u003cli\u003eReduction of inherent power loss\u003c\/li\u003e\n  \u003cli\u003eLess heating of the control cabinet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eThe Siemens 3RV20314BB10 motor protection circuit breaker offers reliable overload and short-circuit protection for motors in industrial and commercial applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: SIEMENS\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 3RV20314BB10\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUNSPSC Code\u003c\/strong\u003e: 39120000\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: SIEMENS\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e: 20 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 3RV20314BB10\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SIRIUS\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUPC Code\u003c\/strong\u003e: 887621919870\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Range\u003c\/strong\u003e: 14 to 20\/260 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire Size\u003c\/strong\u003e: 18 to 3 AWG, 18 to 2 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUNSPSC\u003c\/strong\u003e: 39121601\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Motor Circuit Protector Breaker\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage Maximum\u003c\/strong\u003e: 690VAC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e: 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eContinuous Amps\u003c\/strong\u003e: 20A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStarter Size\u003c\/strong\u003e: NEMA 2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrip Setting Amps\u003c\/strong\u003e: 14.0-20.0A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMotor FLA\u003c\/strong\u003e: 20A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminals\u003c\/strong\u003e: Screw\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Germany - Subject to change\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnection type\u003c\/strong\u003e: Screw connection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGreatest value of overload release adjustment range\u003c\/strong\u003e: 20 ampere\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated auxiliary switch present\u003c\/strong\u003e: FALSE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated undervoltage tripper present\u003c\/strong\u003e: FALSE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLowest value of setting range for overload tripper\u003c\/strong\u003e: 14 ampere\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManner of using\u003c\/strong\u003e: Toggle\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003emax. rated operating voltage\u003c\/strong\u003e: 690 volt\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003emin. rated operating voltage\u003c\/strong\u003e: 690 volt\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePole number\u003c\/strong\u003e: 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower loss per pole; current-dependent [PlIp]\u003c\/strong\u003e: 4.8 watt\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProtection type IP\u003c\/strong\u003e: IP20\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated current [In] for the power loss specification\u003c\/strong\u003e: 20 ampere\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated operating power with AC-3; 230 V\u003c\/strong\u003e: 6 kilowatt\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated operating power with AC-3; 400 V\u003c\/strong\u003e: 8 kilowatt\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated permanent current Iu\u003c\/strong\u003e: 20 ampere\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003erated service short-circuit breaking capacity Ics at 400 V; 50 Hz\u003c\/strong\u003e: 650 ampere\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRelease system\u003c\/strong\u003e: magnetic\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensitive to phase failure\u003c\/strong\u003e: TRUE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003esuitable for mounting onto standard rails\u003c\/strong\u003e: FALSE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage Rating - AC\u003c\/strong\u003e: 690 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eActuator Type\u003c\/strong\u003e: Rotary\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackaging\u003c\/strong\u003e: Box\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIllumination\u003c\/strong\u003e: None\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Type\u003c\/strong\u003e: DIN Rail\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApproval Agency\u003c\/strong\u003e: CCC, CE, CSA, EAC, UL, VDE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBreaker Type\u003c\/strong\u003e: Thermal Magnetic\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"SIEMENS","offers":[{"title":"Default Title","offer_id":51149771112754,"sku":"3RV20314BB10","price":657.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/305981171.jpg?v=1778601113","url":"https:\/\/voomisupply.com\/products\/siemens-3rv20314bb10-circuit-breaker-for-motor-protection-s2-class-20-14-20a-screw-3rv2-series","provider":"Voomi Supply","version":"1.0","type":"link"}