{"product_id":"siemens-3rq41181am00-output-coupler-with-plug-in-relay-24-v-dc-6-2-mm","title":"Siemens 3RQ41181AM00 Output Coupler with Plug-In Relay 24 V DC 6.2 mm","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe SIEMENS 3RQ41181AM00 is an output coupler with a plug-in relay designed for 24 V DC applications. It provides electrical separation, amplification, and signal conditioning between the controller and I\/O. This narrow design is suitable for control and signaling applications with a thermal current of 6 A.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCoupling relay for electrical separation\u003c\/li\u003e\n  \u003cli\u003eFeatures amplification and signal conditioning\u003c\/li\u003e\n  \u003cli\u003eNarrow 6.2 mm design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eThe SIEMENS 3RQ41181AM00 output coupler offers a compact solution for control and signaling applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: SIEMENS\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 3RQ41181AM00\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eproduct brand name\u003c\/strong\u003e: SIRIUS\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eproduct category\u003c\/strong\u003e: SIRIUS 3RQ4 coupling relay, narrow design\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eproduct designation\u003c\/strong\u003e: Coupling relay with plug-in relay\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003edesign of the product\u003c\/strong\u003e: output coupling link\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eproduct type designation\u003c\/strong\u003e: 3RQ4\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003edisplay version LED\u003c\/strong\u003e: Yes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eproduct feature protective coating on printed-circuit board\u003c\/strong\u003e: No\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eproduct component relay output\u003c\/strong\u003e: Yes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eproduct component semi-conductor output\u003c\/strong\u003e: No\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003epower loss [W] maximum\u003c\/strong\u003e: 0.25 W\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003econsumed active power\u003c\/strong\u003e: 0.3 W\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003einsulation voltage for overvoltage category III according to IEC 60664 with degree of pollution 3 rated value\u003c\/strong\u003e: 300 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003esurge voltage resistance rated value\u003c\/strong\u003e: 4 kV\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003emaximum permissible voltage for protective separation between control and auxiliary circuit\u003c\/strong\u003e: 300 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003emaximum permissible voltage for protective separation between control and auxiliary circuit according to IEC 60947-1\u003c\/strong\u003e: 300 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003epercental drop-out voltage related to the input voltage\u003c\/strong\u003e: 10 %\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eflammability class of enclosure material\u003c\/strong\u003e: UL94 V-0\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eshock resistance according to IEC 60068-2-27\u003c\/strong\u003e: sinusoidal half-wave 15g \/ 11 ms\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003evibration resistance according to IEC 60068-2-6\u003c\/strong\u003e: 6 ... 150 Hz: 2 g\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eoperating frequency maximum\u003c\/strong\u003e: 72 000 1\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eswitching behavior\u003c\/strong\u003e: monostable\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003emechanical service life (operating cycles) typical\u003c\/strong\u003e: 10 000 000\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eelectrical endurance (operating cycles) at AC-15 at 250 V typical\u003c\/strong\u003e: 100 000\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ethermal current\u003c\/strong\u003e: 6 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ereference code according to IEC 81346-2\u003c\/strong\u003e: K\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003econtrol supply voltage at DC rated value\u003c\/strong\u003e: 24 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eoperating range factor control supply voltage rated value at DC initial value\u003c\/strong\u003e: 0.8\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eoperating range factor control supply voltage rated value at DC full-scale value\u003c\/strong\u003e: 1.25\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eON-delay time at AC maximum\u003c\/strong\u003e: 10 ms\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eON-delay time at DC maximum\u003c\/strong\u003e: 10 ms\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOFF-delay time maximum\u003c\/strong\u003e: 10 ms\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003edesign of the switching function positively driven\u003c\/strong\u003e: No\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eproperty of the output short-circuit proof\u003c\/strong\u003e: No\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eproduct component plug-in socket\u003c\/strong\u003e: Yes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003edesign of the relay operating mechanism\u003c\/strong\u003e: poled\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003edesign of the fuse link for short-circuit protection of the auxiliary switch required\u003c\/strong\u003e: fuse gG: 4 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003etype of switching contact\u003c\/strong\u003e: Changeover contact\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ematerial of switching contacts\u003c\/strong\u003e: AgSnO2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003enumber of CO contacts for auxiliary contacts\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eoperational current of auxiliary contacts at AC-15 at 24 V\u003c\/strong\u003e: 3 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eoperational current of auxiliary contacts at AC-15 at 250 V\u003c\/strong\u003e: 3 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eoperational current of auxiliary contacts at DC-13 at 24 V\u003c\/strong\u003e: 1 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eoperational current of auxiliary contacts at DC-13 at 125 V\u003c\/strong\u003e: 0.2 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eoperational current of auxiliary contacts at DC-13 at 250 V\u003c\/strong\u003e: 0.1 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003econtact reliability of auxiliary contacts\u003c\/strong\u003e: one incorrect switching operation of 100 million switching operations (17 V, 5 mA)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003etype of voltage\u003c\/strong\u003e: DC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eampacity of the output relay at AC-15 at 250 V at 50\/60 Hz\u003c\/strong\u003e: 3 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eampacity of the output relay at DC-13 at 24 V\u003c\/strong\u003e: 1 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eampacity of the output relay at DC-13 at 125 V\u003c\/strong\u003e: 0.2 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eampacity of the output relay at DC-13 at 250 V\u003c\/strong\u003e: 0.1 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eelectromagnetic compatibility\u003c\/strong\u003e: acc. to EN 60947-5-1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEMC emitted interference according to IEC 60947-1 ambience\u003c\/strong\u003e: A (industrial sector)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEMC immunity according to IEC 60947-1 corresponds to degree of severity\u003c\/strong\u003e: 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003econducted interference due to burst according to IEC 61000-4-4\u003c\/strong\u003e: 2 kV\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003econducted interference due to conductor-earth surge according to IEC 61000-4-5\u003c\/strong\u003e: 2 kV\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003econducted interference due to conductor-conductor surge according to IEC 61000-4-5\u003c\/strong\u003e: 1 kV\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003efield-based interference according to IEC 61000-4-3\u003c\/strong\u003e: 10 V\/m\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eelectrostatic discharge according to IEC 61000-4-2\u003c\/strong\u003e: 6 kV contact discharge \/ 8 kV air discharge\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003edisplay version as status display by LED\u003c\/strong\u003e: LED green\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eproduct function removable terminal\u003c\/strong\u003e: No\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003etype of electrical connection for auxiliary and control circuits\u003c\/strong\u003e: screw-type terminals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003etype of connectable conductor cross-sections solid\u003c\/strong\u003e: 1x (0.25 ... 2.5 mm\n\n2)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003etype of connectable conductor cross-sections finely stranded with core end processing\u003c\/strong\u003e: 1x (0.25 ... 2.5 mm\n\n2), 2x (0.25 ... 1.5 mm\n\n2)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003efor AWG cables solid\u003c\/strong\u003e: 1x (20 ... 14), 2x (20 ... 16)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003econnectable conductor cross-section solid\u003c\/strong\u003e: 0.25 ... 2.5 mm\n\n2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003econnectable conductor cross-section finely stranded with core end processing\u003c\/strong\u003e: 0.25 ... 2.5 mm\n\n2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAWG number as coded connectable conductor cross section solid\u003c\/strong\u003e: 20 ... 14\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003etightening torque with screw-type terminals\u003c\/strong\u003e: 0.5 ... 0.6 N\n\n\nm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003esize of the screwdriver tip\u003c\/strong\u003e: 3,0 x 0,5 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003estripped length\u003c\/strong\u003e: 10 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003emounting position\u003c\/strong\u003e: any\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003efastening method\u003c\/strong\u003e: snap-on mounting\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eheight\u003c\/strong\u003e: 93 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ewidth\u003c\/strong\u003e: 6.2 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003edepth\u003c\/strong\u003e: 88.5 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003erequired spacing with side-by-side mounting forwards\u003c\/strong\u003e: 0 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003erequired spacing with side-by-side mounting backwards\u003c\/strong\u003e: 0 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003erequired spacing with side-by-side mounting upwards\u003c\/strong\u003e: 0 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003erequired spacing with side-by-side mounting downwards\u003c\/strong\u003e: 0 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003erequired spacing with side-by-side mounting at the side\u003c\/strong\u003e: 0 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003erequired spacing for grounded parts forwards\u003c\/strong\u003e: 0 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003erequired spacing for grounded parts backwards\u003c\/strong\u003e: 0 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003erequired spacing for grounded parts upwards\u003c\/strong\u003e: 0 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003erequired spacing for grounded parts at the side\u003c\/strong\u003e: 0 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003erequired spacing for grounded parts downwards\u003c\/strong\u003e: 0 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003erequired spacing for live parts forwards\u003c\/strong\u003e: 0 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003erequired spacing for live parts backwards\u003c\/strong\u003e: 0 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003erequired spacing for live parts upwards\u003c\/strong\u003e: 0 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003erequired spacing for live parts downwards\u003c\/strong\u003e: 0 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003erequired spacing for live parts at the side\u003c\/strong\u003e: 0 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003einstallation altitude at height above sea level maximum\u003c\/strong\u003e: 2 000 m\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eambient temperature during operation\u003c\/strong\u003e: -25 ... +60 \n\n\nC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eambient temperature during storage\u003c\/strong\u003e: -40 ... +85 \n\n\nC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eambient temperature during transport\u003c\/strong\u003e: -40 ... +85 \n\n\nC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003erelative humidity during operation\u003c\/strong\u003e: 10 ... 95 %\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"SIEMENS","offers":[{"title":"Default Title","offer_id":51149533118770,"sku":"3RQ41181AM00","price":85.56,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/305980707.png?v=1778596432","url":"https:\/\/voomisupply.com\/products\/siemens-3rq41181am00-output-coupler-with-plug-in-relay-24-v-dc-6-2-mm","provider":"Voomi Supply","version":"1.0","type":"link"}