{"product_id":"schneider-electric-lc2d12g7v-iec-reversible-contactor-3-pole-12a","title":"Schneider Electric LC2D12G7V Iec Reversible Contactor 3 Pole 12A","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\u003cp\u003eThe SCHNEIDER ELECTRIC LC2D12G7V is a 3-pole IEC reversible contactor rated at 12 amps at 440 Vac, designed for motor reversing and switching applications in industrial and commercial control panels. The coil operates at 120 Vac at 50\/60 Hz, making it compatible with standard North American control-circuit voltages. It includes an auxiliary contact configuration of one normally closed (NC) and one normally open (NO), supporting interlocking and feedback circuits. Licensed electricians and industrial control technicians install this device in motor starter assemblies, conveyor systems, pump controls, and similar three-phase load applications where forward and reverse operation is required.\u003c\/p\u003e\u003cp\u003eThe LC2D12G7V is suited for three-phase motor control installations in light industrial and commercial environments. Its reversible action allows a single contactor assembly to handle bidirectional motor switching without requiring separate forward and reverse units. The built-in NC and NO auxiliary contacts support standard interlocking schemes used in motor control circuits. This contactor is appropriate for panel builders, maintenance electricians, and automation technicians working on replacement or new-build motor control centers.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eReversible contactor action supports forward and reverse motor control in a single unit\u003c\/li\u003e\n\u003cli\u003e3-pole configuration rated at 12A at 440 Vac for three-phase load switching\u003c\/li\u003e\n\u003cli\u003e120 Vac coil voltage at 50\/60 Hz suits standard North American control circuits\u003c\/li\u003e\n\u003cli\u003eAuxiliary contacts include one NC and one NO for interlocking and status feedback\u003c\/li\u003e\n\u003cli\u003eMeets multiple international standards including UL 508, CSA C22.2 No. 14, EN\/IEC 60947-4-1, and RoHS Compliant\u003c\/li\u003e\n\u003cli\u003eCompact footprint suitable for space-constrained control panel installations\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\u003cp\u003eDesigned as an OEM-style IEC reversible contactor replacement for 3-pole motor control applications requiring a 120 Vac coil and NC\/NO auxiliary contact configuration per EN\/IEC 60947-4-1.\u003c\/p\u003e\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\u003cp\u003eInstallation should be performed by a licensed electrician in accordance with NEC requirements and applicable local codes. De-energize and lock out the control panel before removing or installing the contactor. Verify coil voltage and pole rating match the existing circuit before energizing. Confirm auxiliary contact interlocking wiring is correct before commissioning a reversing motor circuit to prevent simultaneous forward and reverse energization.\u003c\/p\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e: 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage\u003c\/strong\u003e: 12A at 440 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e: 120 Vac at 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAction\u003c\/strong\u003e: Reversible\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary Contact Configuration\u003c\/strong\u003e: NC and NO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall Height\u003c\/strong\u003e: 3.03 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall Width\u003c\/strong\u003e: 3.54 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall Depth\u003c\/strong\u003e: 3.39 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 1.8 pounds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards\u003c\/strong\u003e: UL 508, UL Listed, CSA, CSA C22.2 No. 14, EN\/IEC 60947-4-1, EN\/IEC 60947-5-1, RoHS Compliant, Bureau Veritas, CCC, DNV, GL, GOST, LROS, RINA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandard Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: SCHNEIDER ELECTRIC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: LC2D12G7V\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SCHNEIDER ELECTRIC","offers":[{"title":"Default Title","offer_id":51540567589170,"sku":"LC2D12G7V","price":549.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/84dc03701550a6de71acd54290d3e4ea_dcbba913-a631-4f2e-9cf6-950d3f4d5800.jpg?v=1785858619","url":"https:\/\/voomisupply.com\/products\/schneider-electric-lc2d12g7v-iec-reversible-contactor-3-pole-12a","provider":"Voomi Supply","version":"1.0","type":"link"}