{"product_id":"sauermann-28149-si-rm450-manifold-kit-6","title":"Sauermann 28149 Si-RM450 Manifold Kit 6","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe SAUERMANN 28149 Si-RM450 Manifold Kit 6 includes the Si-RM450 4-Valve Digital Manifold, two Si-RT7 Wireless Temperature Clamp Probes, a Si-RV4 Wireless Vacuum Probe, and a four-piece hose set. Compatible with A1\/A2\/A2L\/A3 refrigerants, it pairs with the Sauermann Pilot mobile app for servicing refrigerant-based installations. The smart digital assistant guides the operator for efficient system diagnostics.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eKit combines Si-RM450 4-Valve Digital Manifold with 2x Si-RT7 Wireless Temperature Clamp Probes, 1x Si-RV4 Wireless Vacuum Probe, and 1x 4-Piece Hose Set\u003c\/li\u003e\n  \u003cli\u003eAids in commissioning and servicing heat pumps, A\/C, refrigeration, and reversible systems from domestic systems to complex industrial machines\u003c\/li\u003e\n  \u003cli\u003eWired and wireless probes offer additional measurement capabilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eThe kit is user-friendly with troubleshooting diagnostics, supports 130+ refrigerants with updates, and has a daylight-friendly display.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: SAUERMANN\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 28149\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDisplay Style\u003c\/strong\u003e: Digital\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Valves\u003c\/strong\u003e: 4\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature Units\u003c\/strong\u003e: \"\".F\/\"\".C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePressure Units\u003c\/strong\u003e: psi\/bar\/kPa\/MPa\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply\u003c\/strong\u003e: 4x LR6 or AA 1.5V batteries, USB-C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBattery Life\u003c\/strong\u003e: 300 hours\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMemory\u003c\/strong\u003e: Up to 600000 points\/9 days of recording\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDisplay\u003c\/strong\u003e: 240 x 128 px\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePressure Valves\u003c\/strong\u003e: 4x (4-way)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePressure Measurement Range\u003c\/strong\u003e: -14 to 870 psi (-1 to 60 bar)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePressure Sensing Accuracy\u003c\/strong\u003e: \"\".(5% m.v. \"\".5 microns), from 100 to 2000 microns\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResolution\u003c\/strong\u003e: 0.01 bar \/ 0.1 psi \/ 1 kPa \/ 0.001 MPa\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOverload\u003c\/strong\u003e: 65 bar (943 psi)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBurst Pressure\u003c\/strong\u003e: 150 bar (2175 psi)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature Measurement Range\u003c\/strong\u003e: -4\".F to 140\".F (-20\".C to 60\".C)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature Accuracy\u003c\/strong\u003e: \"\".6\".F (\"\".3\".C), from -4\".F to 32\".F (-20\".C to 0\".C)\/\"\".9\".F (\"\".5\".C), from 32\".F to 150\".F (0\".C to 60\".C)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature Resolution\u003c\/strong\u003e: 0.1\".F\/0.1\".C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHumidity Measurement Range\u003c\/strong\u003e: 0% to 100% RH\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHumidity Accuracy\u003c\/strong\u003e: \"\".2% RH, from 15\".C to 25\".C and 10% to 90% RH\/\"\".5% RH, from 15\".C to 25\".C, 0% to 10% RH, and 90% to 100% RH\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHumidity Resolution\u003c\/strong\u003e: 0.1% RH\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResponse Time\u003c\/strong\u003e: 60 sec.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMax pressure hose\u003c\/strong\u003e: 55 bar (800 psi)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLanguages\u003c\/strong\u003e: English, French, Spanish, Italian, German, Chinese, Portuguese, Romanian, Hungarian, Polish, Dutch\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePressure connectors\u003c\/strong\u003e: Si-RM350: 3x 1\/4 MFL male\nSi-RM450: 3x 1\/4 MFL male + 1x 3\/8 MFL male\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature connectors\u003c\/strong\u003e: 2x wired jack (NTC)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWireless frequency\u003c\/strong\u003e: Range frequency from 2402 MHz to 2480 MHz with a transmission power of 8 dBm.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWireless range\u003c\/strong\u003e: App connection: depends on smartphone radio strength, range up to 100 m (328 ft).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatibility\u003c\/strong\u003e: Smartphone minimum required versions: Android 11.0, iOS 15, BLE 5.0***\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePort\u003c\/strong\u003e: USB-C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSuperheat and subcooling\u003c\/strong\u003e: Automatically calculated by the device\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental conditions of use\u003c\/strong\u003e: In non-condensing condition\nAltitude: from 0 to 2000 m (0 to 6561 ft)\nNon-corrosive gases\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: From -20 to 50\".C (-4 to 122\".F)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStorage temperature\u003c\/strong\u003e: -20 to 50\".C (-4 to 122\".F)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType of probe\u003c\/strong\u003e: Si-RT2\nSi-RT7\nSi-RT5\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature sensors\u003c\/strong\u003e: NTC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature sensor range\u003c\/strong\u003e: -50 to 120\".C (-58 to 248\".F)\n-20 to 85\".C (-4 to 185\".F)\n-20 to 85\".C (-4 to 185\".F)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature accuracy*\u003c\/strong\u003e: -20 to 85\".C (4 to 185\".F): \"\".1\".C (\"\".8\".F)\n-20\".C to 70\".C (-4 to 158\".F): \"\".2\".C (\"\".4\".F)\n70\".C to 85\".C (158 to 185\".F): \"\".5\".C (\"\".9\".F)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum operating temperatures\u003c\/strong\u003e: Jaws: 150\".C (302\".F) - Handle: 90\".C (194\".F)\nJaws: 85\".C (185\".F) - Handle: 50\".C (122\".F)\nN\/A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAvailable units (Temperature)\u003c\/strong\u003e: \".C, \".F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResolution (Temperature)\u003c\/strong\u003e: 0.1\".C, 0.1\".F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePipes diameter\u003c\/strong\u003e: 6 to 42 mm (0.2\" to 1.7\")\nmax 100 mm (max. 3.9\")\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMeasurement and discharge valves\u003c\/strong\u003e: 1x vacuum input\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMeasuring range (Vacuum)\u003c\/strong\u003e: 50 microns to 25 000 microns\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePressure sensing accuracy* (Vacuum)\u003c\/strong\u003e: 100 to 2000 microns: \"\".(5% m.v. \"\".5 microns)\nTemperature dependence: \"\".0005 x (T-20) microns (if T\u0026lt;0\".C or T\u0026gt;30\".C)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAvailable units (Vacuum)\u003c\/strong\u003e: micron \/ mbar \/ Torr \/ mTorr \/ inH2 O \/ inHg \/ mmHg \/ hPa \/ Pa\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResolution (Vacuum)\u003c\/strong\u003e: 1 micron (50 to 1 000 microns) \/ 10 microns above\n0.00001 mbar (0.06666 to 1.33322 mbar) \/ 0.0001 mbar above\n0.001 Torr (0.050 to 1.000 Torr) \/ 0.01 Torr above\n1 mTorr (50 to 1 000 mTorr) \/ 10 mTorr above\n0.0001 inH2 0 (0.0267 to 0.5352 inH2 O) \/ 0.01 inH2 O above\n0.000001 inHg (0.001968 to 0.039370 inHg) \/ 0.00001 inHg above\n0.001 mmHg (0.050 to 1.000 mmHg) \/ 0.01 mmHg above\n0.0001 hPa (0.0666 to 1.3332 hPa) \/ 0.001 hPa above\n0.01 Pa (6.66 to 133.32 Pa) \/ 0.1 Pa above\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOverload (Vacuum)\u003c\/strong\u003e: 27.5 bar (400 psi)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBurst pressure (Vacuum)\u003c\/strong\u003e: 35 bar (507 psi)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWireless range (Vacuum)\u003c\/strong\u003e: Range up to 100 m (328 ft)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eParameter\u003c\/strong\u003e: Temperature\nHumidity\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMeasuring range (Thermo-Hygrometry)\u003c\/strong\u003e: -20 to 60\".C (4 to 140\".F)\n0 to 100 %RH\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAccuracy* (Thermo-Hygrometry)\u003c\/strong\u003e: -20 to 0\".C (-4 to 32\".F): \"\".3\".C (0.6\".F)\n0\".C to 60\".C (32 to 150\".F): \"\".5\".C (0.9\".F)\n10 to 90 %RH: \"\".2 %RH\n0 to 10 %RH \/ 90 to 100 %RH: \"\".5 %RH\n\"\".04 x (T-20)%RH (if T\u0026lt;15\".C\/33.8\".F or T\u0026gt;25\".C\/77\".F)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStorage temperature (Thermo-Hygrometry)\u003c\/strong\u003e: -20 to 50\".C (-4 to 122\".F)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAvailable units (Thermo-Hygrometry)\u003c\/strong\u003e: \".C, \".F\n%RH\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResolution (Thermo-Hygrometry)\u003c\/strong\u003e: 0.1\".C, 0.1\".F\n0.1 %RH\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWireless range (Thermo-Hygrometry)\u003c\/strong\u003e: Range up to 100 m (328 ft)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVacuum Measurement\/Discharge Valves\u003c\/strong\u003e: 1x vacuum input\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVacuum Measurement Range\u003c\/strong\u003e: 50 microns to 25000 microns\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePipe Diameter (Si-RT2\/Si-RT7)\u003c\/strong\u003e: 0.2 in. to 1.7 in. (6 mm to 42 mm)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePipe Diameter (Si-RT5)\u003c\/strong\u003e: 3.9 in. (100 mm)\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"SAUERMANN","offers":[{"title":"Default Title","offer_id":51138335047986,"sku":"28149","price":1307.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/305527444.jpg?v=1778253665","url":"https:\/\/voomisupply.com\/products\/sauermann-28149-si-rm450-manifold-kit-6","provider":"Voomi Supply","version":"1.0","type":"link"}