{"product_id":"runtru-a801x120dm5sb-gas-furnace-120k-btu-80-afue-multi-speed-multi-positional","title":"Trane A801X120DM5SB Gas Furnace 80 Percent Afue Single Stage 120000 Btu\/h Input Upflow Horizontal","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe Trane A801X120DM5SB is a single-stage, induced-draft gas furnace rated at 80 percent AFUE with a 120,000 BTU\/h heating input capacity. It operates on a 24-volt control system and delivers up to 2,000 nominal CFM of airflow through a 9-tap CTM blower motor configuration. The cabinet measures 24.5 inches wide, 28.75 inches deep, and 34 inches tall, making it suitable for installations where cabinet footprint is a design constraint. This furnace is installed by licensed HVAC technicians in residential and light-commercial forced-air heating applications.\u003c\/p\u003e\n\u003cp\u003eThe A801X120DM5SB supports multiple installation orientations, including upflow, horizontal left, horizontal right, and downflow (UP\/HL\/HR\/DN poise), giving installers flexibility across a range of job conditions. It is designed for use in split-system configurations paired with a compatible evaporator coil and condensing unit. The induced-draft combustion system and single-stage gas valve make this a straightforward replacement or new-construction unit for standard residential heating loads requiring higher input capacity.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e80 percent AFUE single-stage induced-draft operation for reliable heating performance\u003c\/li\u003e\n  \u003cli\u003e120,000 BTU\/h heating input capacity suited for larger residential or light-commercial spaces\u003c\/li\u003e\n  \u003cli\u003eMulti-poise installation support: upflow, horizontal left, horizontal right, and downflow\u003c\/li\u003e\n  \u003cli\u003e9-tap CTM blower motor allows field adjustment of airflow to match duct system requirements\u003c\/li\u003e\n  \u003cli\u003e2,000 nominal CFM output supports larger duct systems and higher static pressure designs\u003c\/li\u003e\n  \u003cli\u003e24-volt control circuit compatible with standard thermostat and zone control wiring\u003c\/li\u003e\n  \u003cli\u003e24.5-inch cabinet width fits common residential equipment closet and utility room openings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM-style replacement or new-installation gas furnace for residential forced-air heating systems requiring an 80 percent AFUE, single-stage, induced-draft unit with a 24.5-inch cabinet width.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed HVAC technician in accordance with local mechanical codes and the current edition of the International Fuel Gas Code. Shut off the gas supply and disconnect electrical power at the breaker before beginning any work. Verify flue venting meets local code for 80 percent induced-draft appliances before commissioning. Do not attempt to convert gas type or alter the heat exchanger without factory-authorized guidance.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAFUE\u003c\/strong\u003e: 80 percent\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeating Stages\u003c\/strong\u003e: Single Stage\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeating Input Capacity\u003c\/strong\u003e: 120,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNominal Airflow\u003c\/strong\u003e: 2,000 CFM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBlower Motor Taps\u003c\/strong\u003e: 9-tap CTM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eControl Voltage\u003c\/strong\u003e: 24 volts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCabinet Width\u003c\/strong\u003e: 24.5 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCabinet Depth\u003c\/strong\u003e: 28.75 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCabinet Height\u003c\/strong\u003e: 34 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInstallation Orientations\u003c\/strong\u003e: Upflow, Horizontal Left, Horizontal Right, Downflow\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCombustion System\u003c\/strong\u003e: Induced Draft\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Trane\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: A801X120DM5SB\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TRANE","offers":[{"title":"Default Title","offer_id":51217051320626,"sku":"A801X120DM5SB","price":1290.37,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/308796699.jpg?v=1780588727","url":"https:\/\/voomisupply.com\/products\/runtru-a801x120dm5sb-gas-furnace-120k-btu-80-afue-multi-speed-multi-positional","provider":"Voomi Supply","version":"1.0","type":"link"}