{"product_id":"runtru-a801x080bm4sc-gas-furnace-80k-btu-80-afue-single-stage-multi-positional","title":"Trane A801X080BM4SC 80 Percent Afue Gas Furnace 80000 Btu Multipositional Upflow Downflow Horizontal","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe Trane A801X080BM4SC is a single-stage, multipositional gas furnace rated at 80,000 BTU input capacity and 80 percent AFUE efficiency. It is designed for residential forced-air heating systems and can be installed in upflow, downflow, or horizontal left\/right orientations, making it adaptable to a wide range of installation layouts. The furnace operates on 120\/1\/60 voltage with 24-volt low-voltage control and features an integrated furnace control board with digital display, setup and diagnostic functions, and storage of the last six fault codes. All electrical connections use Molex connectors. A four-speed direct-drive blower motor handles airflow for both heating and cooling modes. Licensed HVAC technicians perform installation and service.\u003c\/p\u003e\n\u003cp\u003eThe A801X080BM4SC is suited for residential applications where a single-stage, non-condensing gas furnace is specified. Its multipositional cabinet design accommodates upflow, downflow, and horizontal installations, giving installers flexibility in equipment room, closet, attic, and crawlspace placements. The open vestibule design provides a full 34-inch high access area for ease of service. The cabinet width of 17.5 inches is compatible with industry-standard evaporator coils and accessories, making it a practical choice for split-system configurations where a matched or compatible cooling coil is installed above or below the unit.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e80,000 BTU input capacity with 80 percent AFUE single-stage heating\u003c\/li\u003e\n  \u003cli\u003eMultipositional installation: upflow, downflow, horizontal left, and horizontal right\u003c\/li\u003e\n  \u003cli\u003eIntegrated furnace control board with digital display and last-six-error fault memory\u003c\/li\u003e\n  \u003cli\u003eFour-speed direct-drive blower motor rated at 1,600 CFM, suitable for up to 4-ton cooling\u003c\/li\u003e\n  \u003cli\u003eAll Molex electrical connections — no spade terminals\u003c\/li\u003e\n  \u003cli\u003eAir-tight cabinet with 1.4 percent or less air leakage per ASHRAE 193\u003c\/li\u003e\n  \u003cli\u003eOpen vestibule design with 34-inch clearance height for accessible service\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eThe A801X080BM4SC has a 17.5-inch wide cabinet compatible with industry-standard evaporator coils and accessories. It has been listed as a component in 2.5-ton split-system configurations paired with matched cooling equipment. Confirm coil and system compatibility with Trane or RunTru selection guides before installation.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed HVAC technician in accordance with local mechanical codes, the National Fuel Gas Code (NFPA 54\/ANSI Z223.1), and the manufacturer's installation, operation, and maintenance manual. Shut off gas supply and disconnect electrical power before beginning any service or installation work. Vent this furnace using approved non-condensing vent materials sized per the venting tables in the installation guide; do not use PVC for flue venting on this 80 percent AFUE unit. Verify proper gas line sizing, combustion air supply, and condensate drainage provisions before startup.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Capacity\u003c\/strong\u003e: 80,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAFUE\u003c\/strong\u003e: 80 percent\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStages\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBlower CFM Rating\u003c\/strong\u003e: 1,600 CFM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBlower Size\u003c\/strong\u003e: 11 x 8 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBlower Motor Speed\u003c\/strong\u003e: 1,075 RPM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMotor Power\u003c\/strong\u003e: 3\/4 HP\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 120 volts AC, 60 Hz, 1-Phase\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eControl Voltage\u003c\/strong\u003e: 24 volts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e: 13.06 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCabinet Height\u003c\/strong\u003e: 34 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCabinet Width\u003c\/strong\u003e: 17.5 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCabinet Depth\u003c\/strong\u003e: 28.75 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInstallation Positions\u003c\/strong\u003e: Upflow, Downflow, Horizontal Left, Horizontal Right\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAir Leakage\u003c\/strong\u003e: 1.4 percent or less per ASHRAE 193\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Trane\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: A801X080BM4SC\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TRANE","offers":[{"title":"Default Title","offer_id":51217047060786,"sku":"A801X080BM4SC","price":1164.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/308796702.png?v=1780588596","url":"https:\/\/voomisupply.com\/products\/runtru-a801x080bm4sc-gas-furnace-80k-btu-80-afue-single-stage-multi-positional","provider":"Voomi Supply","version":"1.0","type":"link"}