{"product_id":"phoenix-contact-3002609-pt-4-l-hesiled-24-5x20-fuse-modular-terminal-block","title":"Phoenix Contact 3002609 PT 4-L\/HESILED 24 (5X20) Fuse Modular Terminal Block","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe PHOENIX CONTACT 3002609 PT 4-L\/HESILED 24 (5X20) is a fuse modular terminal block with push-in connection. It supports glass, ceramic, and other fuse types, specifically G \/ 5 x 20 fuses. This terminal block features a nominal voltage of 24 V and a nominal current of 28 A, accommodating conductor cross-sections from 0.2 mm² to 6 mm².\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eTime-saving conductor connection thanks to tool-free direct-connection technology\u003c\/li\u003e\n  \u003cli\u003eConvenient plugging with lower insertion force\u003c\/li\u003e\n  \u003cli\u003eEasy integration and replacement of fuses with the lever element\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eFuse modular terminal block with push-in connection and tool-free design for easy fuse replacement and secure connections.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: PHOENIX CONTACT\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 3002609\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: IN\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct type\u003c\/strong\u003e: Fuse terminal block\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of connections\u003c\/strong\u003e: 4\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of rows\u003c\/strong\u003e: 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePotentials\u003c\/strong\u003e: 2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e: III\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDegree of pollution\u003c\/strong\u003e: 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFuse type\u003c\/strong\u003e: Glass \/ ceramics \/ ...\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated surge voltage\u003c\/strong\u003e: 6 kV\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum power dissipation for nominal condition\u003c\/strong\u003e: 1.02 W\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFuse\u003c\/strong\u003e: G \/ 5 x 20\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLED voltage range\u003c\/strong\u003e: 12 V AC\/DC ... 30 V AC\/DC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLED current range\u003c\/strong\u003e: 0.31 mA ... 0.95 mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum power dissipation\u003c\/strong\u003e: max. 1.6 W (with single arrangement of the fuse terminal block in the event of overload)\nmax. 1.6 W (With interconnected arrangement of several fuse terminal blocks in the event of overload)\nmax. 4 W (with single arrangement of the fuse terminal block in the event of a short-circuit)\nmax. 2.5 W (With interconnected arrangement of several fuse terminal blocks in the event of a short-circuit)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 1 Connection method\u003c\/strong\u003e: Push-in connection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 1 Stripping length\u003c\/strong\u003e: 10 mm ... 12 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 1 Internal cylindrical gage\u003c\/strong\u003e: A4\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 1 Connection in acc. with standard\u003c\/strong\u003e: IEC 60947-7-3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 1 Conductor cross-section rigid\u003c\/strong\u003e: 0.2 mm² ... 6 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 1 Cross section AWG\u003c\/strong\u003e: 24 ... 10 (converted acc. to IEC)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 1 Conductor cross-section flexible\u003c\/strong\u003e: 0.2 mm² ... 6 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 1 Conductor cross-section, flexible [AWG]\u003c\/strong\u003e: 24 ... 10 (converted acc. to IEC)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 1 Conductor cross-section flexible ultrasound-compressed\u003c\/strong\u003e: 0.34 mm² ... 6 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 1 Conductor cross-section, flexible [AWG] ultrasound-compressed\u003c\/strong\u003e: 22 ... 10 (converted acc. to IEC)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 1 Conductor cross-section flexible (ferrule without plastic sleeve)\u003c\/strong\u003e: 0.25 mm² ... 4 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 1 Flexible conductor cross-section (ferrule with plastic sleeve)\u003c\/strong\u003e: 0.25 mm² ... 4 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 1 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve\u003c\/strong\u003e: 0.5 mm² ... 1 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 1 Nominal cross section\u003c\/strong\u003e: 4 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 1 Nominal current\u003c\/strong\u003e: 28 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 1 Maximum load current\u003c\/strong\u003e: 32 A (with 6 mm² conductor cross-section, rigid)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 1 Nominal voltage\u003c\/strong\u003e: 24 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 2 Connection method\u003c\/strong\u003e: Push-in connection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 2 Stripping length\u003c\/strong\u003e: 10 mm ... 12 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 2 Connection in acc. with standard\u003c\/strong\u003e: IEC 60947-7-3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 2 Conductor cross-section rigid\u003c\/strong\u003e: 0.2 mm² ... 6 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 2 Cross section AWG\u003c\/strong\u003e: 24 ... 10 (converted acc. to IEC)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 2 Conductor cross-section flexible\u003c\/strong\u003e: 0.2 mm² ... 6 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 2 Conductor cross-section, flexible [AWG]\u003c\/strong\u003e: 24 ... 10 (converted acc. to IEC)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 2 Conductor cross-section flexible (ferrule without plastic sleeve)\u003c\/strong\u003e: 0.25 mm² ... 4 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 2 Flexible conductor cross-section (ferrule with plastic sleeve)\u003c\/strong\u003e: 0.25 mm² ... 4 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 2 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve\u003c\/strong\u003e: 0.5 mm² ... 1 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 2 Nominal cross section\u003c\/strong\u003e: 4 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 2 Nominal current\u003c\/strong\u003e: 6.3 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 2 Maximum load current\u003c\/strong\u003e: 6.3 A (the current is determined by the fuse used)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 2 Nominal voltage\u003c\/strong\u003e: 24 V (the voltage is determined by the light indicator.)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 1 Conductor cross-section rigid directly pluggable\u003c\/strong\u003e: 0.5 mm² ... 6 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 1 Conductor cross-section, rigid [AWG] directly pluggable\u003c\/strong\u003e: 20 ... 10 (converted acc. to IEC)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 1 Conductor cross-section flexible (ferrule without plastic sleeve) directly pluggable\u003c\/strong\u003e: 0.5 mm² ... 4 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 1 Flexible conductor cross-section (ferrule with plastic sleeve) directly pluggable\u003c\/strong\u003e: 0.5 mm² ... 4 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 2 Conductor cross-section rigid directly pluggable\u003c\/strong\u003e: 0.5 mm² ... 6 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 2 Conductor cross-section, rigid [AWG] directly pluggable\u003c\/strong\u003e: 20 ... 10 (converted acc. to IEC)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 2 Conductor cross-section flexible (ferrule without plastic sleeve) directly pluggable\u003c\/strong\u003e: 0.5 mm² ... 4 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLevel 2 Flexible conductor cross-section (ferrule with plastic sleeve) directly pluggable\u003c\/strong\u003e: 0.5 mm² ... 4 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated data (ATEX\/IECEx) Identification\u003c\/strong\u003e:  II 3 G Ex ec llC Gc\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating temperature range\u003c\/strong\u003e: -60 °C ... 130 °C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBridge data 19 A \/ 4 mm²\u003c\/strong\u003e: for bridging with bridge\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBridge data 275 V\u003c\/strong\u003e: - At bridging between non-adjacent terminal blocks\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBridge data 275 V - At cut-to-length bridging with cover\u003c\/strong\u003e: 275 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated insulation voltage\u003c\/strong\u003e: 250 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated voltage\u003c\/strong\u003e: 275 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNominal cross section\u003c\/strong\u003e: 4 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated cross section AWG\u003c\/strong\u003e: 12\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnection capacity rigid\u003c\/strong\u003e: 0.2 mm² ... 6 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnection capacity AWG\u003c\/strong\u003e: 24 ... 12\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnection capacity flexible\u003c\/strong\u003e: 0.2 mm² ... 4 mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated current\u003c\/strong\u003e: 6.3 A (4 mm²)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum load current\u003c\/strong\u003e: 6.3 A (6 mm²)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eContact resistance\u003c\/strong\u003e: 5 mΩ\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature increase\u003c\/strong\u003e: 40 K (29 A\/4 mm²)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWidth\u003c\/strong\u003e: 6.2 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeight\u003c\/strong\u003e: 119.5 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDepth\u003c\/strong\u003e: 82.6 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDepth on NS 35\/7,5\u003c\/strong\u003e: 84.1 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDepth on NS 35\/15\u003c\/strong\u003e: 91.6 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlammability rating according to UL 94\u003c\/strong\u003e: V0\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInsulating material group\u003c\/strong\u003e: I\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInsulating material\u003c\/strong\u003e: PA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStatic insulating material application in cold\u003c\/strong\u003e: -60 °C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRelative insulation material temperature index (Elec., UL 746 B)\u003c\/strong\u003e: 130 °C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFire protection for rail vehicles (DIN EN 45545-2) R22\u003c\/strong\u003e: HL 1 - HL 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFire protection for rail vehicles (DIN EN 45545-2) R23\u003c\/strong\u003e: HL 1 - HL 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFire protection for rail vehicles (DIN EN 45545-2) R24\u003c\/strong\u003e: HL 1 - HL 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFire protection for rail vehicles (DIN EN 45545-2) R26\u003c\/strong\u003e: HL 1 - HL 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSurface flammability NFPA 130 (ASTM E 162)\u003c\/strong\u003e: passed\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSpecific optical density of smoke NFPA 130 (ASTM E 662)\u003c\/strong\u003e: passed\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSmoke gas toxicity NFPA 130 (SMP 800C)\u003c\/strong\u003e: passed\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOpen side panel\u003c\/strong\u003e: Yes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSpecification\u003c\/strong\u003e: DIN EN 50155 (VDE 0115-200):2008-03\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSpectrum\u003c\/strong\u003e: Long life test category 1, class B, body mounted\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFrequency\u003c\/strong\u003e: f1= 5 Hz to f2= 150 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eASD level\u003c\/strong\u003e: 0.964 (m\/s²)²\/Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAcceleration\u003c\/strong\u003e: 5g\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTest duration per axis\u003c\/strong\u003e: 5 h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTest directions\u003c\/strong\u003e: X-, Y- and Z-axis (pos. and neg.)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResult\u003c\/strong\u003e: Test passed\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePulse shape\u003c\/strong\u003e: Half-sine\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShock duration\u003c\/strong\u003e: 30 ms\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of shocks per direction\u003c\/strong\u003e: 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmbient temperature (operation)\u003c\/strong\u003e: -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmbient temperature (storage\/transport)\u003c\/strong\u003e: -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmbient temperature (assembly)\u003c\/strong\u003e: -5 °C ... 70 °C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmbient temperature (actuation)\u003c\/strong\u003e: -5 °C ... 70 °C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePermissible humidity (operation)\u003c\/strong\u003e: 20 % ... 90 %\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePermissible humidity (storage\/transport)\u003c\/strong\u003e: 30 % ... 70 %\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting type\u003c\/strong\u003e: NS 35\/7,5\nNS 35\/15\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: CLIPLINE PT\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Disconnect, Feed Through\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDisconnect Type\u003c\/strong\u003e: Fuse, Lever\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Positions\u003c\/strong\u003e: 4\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Levels\u003c\/strong\u003e: 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTermination Style\u003c\/strong\u003e: Push In\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCurrent - UL\u003c\/strong\u003e: 5 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage - UL\u003c\/strong\u003e: 600V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire Gauge or Range - mm²\u003c\/strong\u003e: 0.2-6mm²\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFeatures\u003c\/strong\u003e: Diode\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFuse Type\u003c\/strong\u003e: 5mm x 20mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eItem\u003c\/strong\u003e: Terminal Block\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnection Type\u003c\/strong\u003e: Push-In\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"PHOENIX CONTACT","offers":[{"title":"Default Title","offer_id":51025891623218,"sku":"3002609","price":32.9,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/298691786.jpg?v=1774901219","url":"https:\/\/voomisupply.com\/products\/phoenix-contact-3002609-pt-4-l-hesiled-24-5x20-fuse-modular-terminal-block","provider":"Voomi Supply","version":"1.0","type":"link"}