{"product_id":"payne-ph16na048p0g-two-stage-heat-pump-16-seer-4-tons","title":"Payne ph16na048p0g Two-stage Heat Pump 16 Seer 4 Tons","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe PAYNE ph16na048p0g is a two-stage, residential split-system heat pump rated at 4 tons nominal cooling capacity and up to 16.5 SEER efficiency. It uses R-410A refrigerant and houses a scroll compressor paired with a two-speed condenser fan motor to deliver variable-output performance in both cooling and heating modes. Cooling capacity ranges from 44,000 to 47,000 BTU\/h, while heating output reaches a minimum of 28,400 BTU\/h. Licensed HVAC technicians install this unit as the outdoor condensing section of a split system, connecting it to a matched indoor air handler or coil.\u003c\/p\u003e\n\u003cp\u003eThis unit is suited for residential applications requiring a high-efficiency outdoor heat pump. The vertical configuration fits standard pad or rooftop installations. Refrigerant line connections are sweat-type, with a 3\/8-inch liquid line and a 1-1\/8-inch suction line. The system uses a TXV metering device on the cooling side and a piston metering device on the heating side. Minimum heating ambient temperature is 55 degrees F. It is a direct replacement for the PH16NA04800G, making it a practical swap in existing Payne split-system installations.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eTwo-stage scroll compressor for part-load efficiency and improved dehumidification\u003c\/li\u003e\n  \u003cli\u003eUp to 16.5 SEER and 8.2 HSPF for high-efficiency operation\u003c\/li\u003e\n  \u003cli\u003eR-410A refrigerant with TXV cooling metering and piston heating metering\u003c\/li\u003e\n  \u003cli\u003eTwo-speed permanent split capacitor condenser fan motor at 825 RPM nominal\u003c\/li\u003e\n  \u003cli\u003eSweat-connection refrigerant lines: 3\/8-inch liquid, 1-1\/8-inch suction\u003c\/li\u003e\n  \u003cli\u003eGrill-style coil guard with 20 fins per inch outdoor coil\u003c\/li\u003e\n  \u003cli\u003eMaximum sound level rated at 75 or more decibels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as a direct OEM-style replacement for the PH16NA04800G in residential split-system heat pump applications. Intended for use with a matched indoor coil or air handler as required by the system design.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed HVAC technician holding an EPA 608 certification for handling R-410A refrigerant. Disconnect and lock out all electrical power before beginning any service or installation work. Follow local mechanical codes and manufacturer wiring diagrams for proper electrical connections, and verify that the circuit breaker and wiring are sized to meet the MCA and maximum overcurrent protection requirements. Do not exceed the maximum piping length specified for this system without consulting manufacturer guidelines.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNominal Cooling Capacity\u003c\/strong\u003e: 44,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Cooling Capacity\u003c\/strong\u003e: 47,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimum Cooling Capacity\u003c\/strong\u003e: 44,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimum Heating Capacity\u003c\/strong\u003e: 28,400 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNominal Tonnage\u003c\/strong\u003e: 4 tons\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSEER\u003c\/strong\u003e: 16.5\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHSPF\u003c\/strong\u003e: 8.2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNominal EER\u003c\/strong\u003e: 12.5\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCOP\u003c\/strong\u003e: 3.68\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRefrigerant\u003c\/strong\u003e: R-410A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompressor Type\u003c\/strong\u003e: Scroll, Two-Stage\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePhase\u003c\/strong\u003e: Single\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFrequency\u003c\/strong\u003e: 60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimum Voltage\u003c\/strong\u003e: 197 volts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Voltage\u003c\/strong\u003e: 253 volts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompressor RLA\u003c\/strong\u003e: 22.8 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLRA\u003c\/strong\u003e: 104 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMCA\u003c\/strong\u003e: 29.8 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Circuit Breaker\u003c\/strong\u003e: 45 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCondenser Fan Motor\u003c\/strong\u003e: Permanent Split Capacitor, 2-Speed, 1\/4 HP, 825 RPM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutdoor Fan Motor FLA\u003c\/strong\u003e: 1.2 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNominal CFM\u003c\/strong\u003e: 4,350 CFM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLiquid Line Size\u003c\/strong\u003e: 3\/8 inches, Sweat\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSuction Line Size\u003c\/strong\u003e: 1-1\/8 inches, Sweat\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMetering Device (Cooling)\u003c\/strong\u003e: TXV\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMetering Device (Heating)\u003c\/strong\u003e: Piston\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimum Heating Ambient Temperature\u003c\/strong\u003e: 55 degrees F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration\u003c\/strong\u003e: Vertical\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMax Sound Level\u003c\/strong\u003e: 75 or more decibels\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutdoor Fins Per Inch\u003c\/strong\u003e: 20 FPI\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCoil Guard\u003c\/strong\u003e: Grill\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLength\u003c\/strong\u003e: 37 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWidth\u003c\/strong\u003e: 37 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeight\u003c\/strong\u003e: 43 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 315 pounds\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: PAYNE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: ph16na048p0g\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"CARRIER","offers":[{"title":"Default Title","offer_id":51138607186226,"sku":"PH16NA048P0G","price":3395.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/305533236.jpg?v=1778781447","url":"https:\/\/voomisupply.com\/products\/payne-ph16na048p0g-two-stage-heat-pump-16-seer-4-tons","provider":"Voomi Supply","version":"1.0","type":"link"}