{"product_id":"parker-ha7vxbg023a-double-solenoid-valve-3-position-120v","title":"Parker HA7VXBG023A Double Solenoid Valve 3-position 120V","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe PARKER HA7VXBG023A is a double solenoid, 3-position directional control valve with a pressure center open unactuated state. It is designed for pneumatic circuit control applications where a fail-safe center position is required to maintain system pressure when neither solenoid is energized. The valve body is machined aluminum with a Buna-N seal and operates on 120 VAC. With a Cv factor of 1.1 and a minimum working pressure of 35 psi, this valve suits light to medium-duty pneumatic actuator circuits. It conforms to ISO 15407-2 and is supplied less base, meaning a manifold or subplate is required for installation.\u003c\/p\u003e\n\u003cp\u003eThis valve is used in industrial and commercial pneumatic control systems where directional control of air to double-acting actuators, cylinders, or other pneumatic devices is needed. The pressure center open configuration allows downstream pressure to be maintained at center position, which is common in clamping, pressing, and positioning applications. It is installed by automation technicians, maintenance mechanics, and pneumatic system integrators working on machine control panels and pneumatic circuits. The ISO 15407-2 footprint ensures compatibility with standard valve manifold bases designed to that specification.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e3-position double solenoid with pressure center open unactuated state for fail-safe system pressure retention\u003c\/li\u003e\n  \u003cli\u003e120 VAC coil voltage suitable for standard industrial control voltage circuits\u003c\/li\u003e\n  \u003cli\u003eAluminum body construction for lightweight, corrosion-resistant service\u003c\/li\u003e\n  \u003cli\u003eBuna-N seals rated for general-purpose air and compatible pneumatic media\u003c\/li\u003e\n  \u003cli\u003eISO 15407-2 compliant footprint for use with standard subplate manifold bases\u003c\/li\u003e\n  \u003cli\u003eCv factor of 1.1 and minimum working pressure of 35 psi for light to medium-duty pneumatic circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned for use with ISO 15407-2 compliant valve manifold bases and subplates. The valve is supplied less base and requires a compatible ISO 15407-2 subplate or manifold for installation. No specific system or model compatibility beyond the ISO 15407-2 standard was provided in the product data.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation should be performed by a qualified automation technician or pneumatic systems mechanic. De-energize and exhaust all system pressure before removing or installing the valve. The valve requires a compatible ISO 15407-2 subplate or manifold base and should not be powered without the base properly seated and fastened. Verify that the supply voltage matches the 120 VAC coil rating before energizing the circuit.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eValve Type\u003c\/strong\u003e: Double Solenoid 3-Position\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnactuated State\u003c\/strong\u003e: Pressure Center Open\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 120 VAC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCv Factor\u003c\/strong\u003e: 1.1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimum Working Pressure\u003c\/strong\u003e: 35 psi\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Temperature\u003c\/strong\u003e: 120 degrees F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBody Material\u003c\/strong\u003e: Aluminum\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeal Material\u003c\/strong\u003e: Buna-N\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard\u003c\/strong\u003e: ISO 15407-2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSupplied\u003c\/strong\u003e: Valve Less Base\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 1 pound\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: PARKER\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: HA7VXBG023A\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PARKER","offers":[{"title":"Default Title","offer_id":51544163746098,"sku":"HA7VXBG023A","price":448.51,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/334b6ff54fec32bf29277dd6826097c9_61b6ca32-124e-4b3b-939f-e4f5655a5938.jpg?v=1785925021","url":"https:\/\/voomisupply.com\/products\/parker-ha7vxbg023a-double-solenoid-valve-3-position-120v","provider":"Voomi Supply","version":"1.0","type":"link"}