{"product_id":"parker-46f-10-12-brass-flared-tube-connector-5-8-in","title":"Parker 46F-10-12 Brass Flared Tube Connector 5\/8 in","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe PARKER 46F-10-12 is a brass flared tube connector designed for secure, leak-resistant connections in fluid and gas line assemblies. It features a 45-degree flare end on one side and a female NPTF (Dryseal) threaded end on the other, providing a reliable transition between flared tubing and pipe-threaded fittings. Rated to 650 psi maximum working pressure and 250 degrees F maximum working temperature, this connector is built for demanding service conditions. The 5\/8 inch tube OD and 3\/4-14 thread size make it a straightforward selection for techs working on refrigeration, HVAC, and hydraulic plumbing lines.\u003c\/p\u003e\n\u003cp\u003eThis fitting is used in residential and light commercial applications where flared copper or brass tubing must connect to a female NPT port. Typical install scenarios include refrigerant line connections, hydraulic circuits, fuel lines, and compressed air systems. Licensed HVAC technicians and pipefitters install this type of connector during new system assembly and service replacement work. The Flare x FNPTF end configuration eliminates the need for additional adapters when transitioning between tube and pipe thread standards.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e45-degree flare end meets SAE J512 and SAE J513 standards for secure tube seating\u003c\/li\u003e\n  \u003cli\u003eFemale NPTF (Dryseal) thread provides a pressure-tight connection without additional sealant\u003c\/li\u003e\n  \u003cli\u003eBrass construction resists corrosion in refrigerant, fuel, and compressed air service\u003c\/li\u003e\n  \u003cli\u003eRated to 650 psi maximum working pressure for high-demand applications\u003c\/li\u003e\n  \u003cli\u003eUL Listed fitting for added assurance in code-sensitive installations\u003c\/li\u003e\n  \u003cli\u003eOverall length of 1.89 inches for compact inline installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM-style replacement or new-installation fitting for systems using 5\/8 inch OD flared tubing with a 3\/4-14 NPTF female port connection, conforming to SAE J512 and SAE J513 flare standards.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eThis fitting is installed by licensed HVAC technicians, pipefitters, or plumbers working on pressurized fluid or gas systems. Depressurize and isolate the system completely before disconnecting or installing any fittings. Ensure the tube end is properly flared to the correct 45-degree angle using a calibrated flaring tool before tightening to avoid leaks. Follow applicable codes, including ASHRAE standards for refrigerant systems and IFGC guidelines where gas lines are involved, and verify all connections with a pressure test before returning the system to service.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaterial\u003c\/strong\u003e: Brass\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFitting Type\u003c\/strong\u003e: Connector\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnd Connection\u003c\/strong\u003e: Flare x FNPTF\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlared Angle\u003c\/strong\u003e: 45 degrees\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTube OD\u003c\/strong\u003e: 5\/8 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThread Size\u003c\/strong\u003e: 3\/4-14\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThread Standard\u003c\/strong\u003e: NPTF\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Working Pressure\u003c\/strong\u003e: 650 psi\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Working Temperature\u003c\/strong\u003e: 250 degrees F (121 degrees C)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOverall Length\u003c\/strong\u003e: 1.89 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.28 pounds\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandards\u003c\/strong\u003e: SAE J512, SAE J513, UL Listing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: PARKER\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 46F-10-12\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PARKER","offers":[{"title":"Default Title","offer_id":51542115090738,"sku":"46F-10-12","price":32.21,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/0839fc8dd5ba0d86f0aad73e10bdfe13.jpg?v=1785892521","url":"https:\/\/voomisupply.com\/products\/parker-46f-10-12-brass-flared-tube-connector-5-8-in","provider":"Voomi Supply","version":"1.0","type":"link"}