{"product_id":"napco-gem-p1632introp-gemini-p1632-security-panel-8-32-zones","title":"Napco GEM-P1632INTROP Gemini P1632 Security Panel, 8-32 Zones","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe NAPCO GEM-P1632INTROP Gemini P1632 Security Panel is designed for residential and light commercial applications. This hardwire\/wireless control panel features programmable partitioning, allowing independent control of two separate areas. With up to 32 user codes, EZ programming, and 400 logged events, this security panel is a foundation for a customizable security system.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eIndependently Control Two Separate Areas\u003c\/li\u003e\n  \u003cli\u003eCompatible with all standard Gemini crystal-control wireless technology\u003c\/li\u003e\n  \u003cli\u003eSupports up to 32 users, 7 keypads, and 400 logged events\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eIdeal for homeowners needing a versatile and comprehensive security system. Features EZ programming and supports two RF receivers, an interior bypass group, and automatic system arming.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: NAPCO\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: GEM-P1632INTROP\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Dominican Republic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eControl Panel\u003c\/strong\u003e: Eight end-of-line resistor burglary zones programmable for Area (expandable to sixteen end-of-line resistors with zone doubling), Exit\/Entry Follower, Day Zone, Chime, Fire Options, Swinger Shutdown, Zone ANDing and a variety of other features\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eZones Supported\u003c\/strong\u003e: Supports up to 32 zones with optional zone-expansion modules, wireless receiver modules and 4-zone keypads\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUsers Supported\u003c\/strong\u003e: Supports up to 32 individually coded users\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutputs\u003c\/strong\u003e: Supports three outputs (Bell, PGM1 and PGM2) and up to eight external relay outputs using the optional Relay Module NPRB3008\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eKeypad Panics\u003c\/strong\u003e: Supports three keypad panics: Fire, Police and Auxiliary\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePartitions\u003c\/strong\u003e: Supports two independent area partitions\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAccess Stations\u003c\/strong\u003e: Supports up to seven access stations (keypads) by up to 32 users\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eX-10 Devices\u003c\/strong\u003e: Supports up to 8 separately-addressable X-10 devices with the optional NPGEMX10 Interface Kit\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLanguage\u003c\/strong\u003e: English-language prompts and system status messages\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eZone Descriptions\u003c\/strong\u003e: User-customized zone descriptions, re-programmable as required\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSmoke Detectors\u003c\/strong\u003e: Supports both 2 and 4-wire smoke detectors\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReporting\u003c\/strong\u003e: Reports alarms, restores and troubles by zone\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEvent Log\u003c\/strong\u003e: 400 event log\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEntry Delay Times\u003c\/strong\u003e: Two programmable entry delay times\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterior Zone Group\u003c\/strong\u003e: One interior zone group\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBattery Test\u003c\/strong\u003e: Dynamic battery test interrupts charging and places battery under load every four hours\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChime\u003c\/strong\u003e: Chime by zone; programmable duration\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProgrammable\u003c\/strong\u003e: Quickloader programmable\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePGM Outputs\u003c\/strong\u003e: 2 PGM outputs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWireless Devices\u003c\/strong\u003e: Supports Gemini wireless devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommunicator\u003c\/strong\u003e: Compatible with all major receiver formats, including 4\/2, SIA and Point ID (except Radionics Modem II)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDial Type\u003c\/strong\u003e: Rotary dial and touch tone with rotary backup\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTelephone Numbers\u003c\/strong\u003e: Three 20-digit telephone numbers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReporting Options\u003c\/strong\u003e: Backup Reporting; Double Reporting; Split Reporting\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUser Codes\u003c\/strong\u003e: 32 user codes with Opening\/Closing- reporting by user\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAC Failure Reporting\u003c\/strong\u003e: AC failure reporting with programmable report delay\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTelephone Line\u003c\/strong\u003e: Supervised telephone line with programmable delay\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePager\u003c\/strong\u003e: Pager capability\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput Power\u003c\/strong\u003e: 500mA\/2A; with optional 40VA trans 650mA\/2A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStep-Down Transformer\u003c\/strong\u003e: 16.5 – 18.0 VAC via Class 2 40VA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 to 49 degrees C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Power\u003c\/strong\u003e: 16.5VAC via Class 2 plug-in 40VA transformer\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLoop Voltage\u003c\/strong\u003e: 10-13VDC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLoop Current\u003c\/strong\u003e: 2.5mA with 2.2k ohm EOLR; 5mA for 2-wire fire\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLoop Resistor\u003c\/strong\u003e: 300 ohm max.; 50 ohm max for 2-wire fire\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAux and Remote Power\u003c\/strong\u003e: 12VDC regulated\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCombined Standby Current\u003c\/strong\u003e: 650mA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAlarm Current\u003c\/strong\u003e: 2A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBurg. Voltage Output\u003c\/strong\u003e: 1; Programmable negative outputs: 2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertifications\u003c\/strong\u003e: UL Listed\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand Name\u003c\/strong\u003e: Napco Security Technologies\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: GEMP1632INTROPK\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Universal Alarm Control\/Communicator\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"NAPCO","offers":[{"title":"Default Title","offer_id":50996976550194,"sku":"GEM-P1632INTROP","price":303.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/297723243.jpg?v=1774028988","url":"https:\/\/voomisupply.com\/products\/napco-gem-p1632introp-gemini-p1632-security-panel-8-32-zones","provider":"Voomi Supply","version":"1.0","type":"link"}