{"product_id":"mitsubishi-electric-wuz-sa48nmz-ecodan-air-to-water-heat-pump-48-000-btu","title":"Mitsubishi Electric WUZ-SA48NMZ Ecodan Air to Water Heat Pump 48,000 BTU","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe Mitsubishi Electric WUZ-SA48NMZ 48,000 BTU Ecodan air-to-water heat pump delivers high-efficiency hydronic heating and cooling for residential and light commercial applications. Featuring advanced inverter technology, it converts outdoor air into hot or chilled water for radiant floor systems, fan coils, and low-temperature baseboards. Ideal for boiler replacement or energy-efficient new construction.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e3-in-1: Hydronic heating,cooling, and domestic hot water\u003c\/li\u003e\n  \u003cli\u003eAuto Changeover: The unit will automatically switch between heating and cooling modes to maintain the set point.\u003c\/li\u003e\n  \u003cli\u003eBoiler Integration : Boiler Integration enables the system to automatically switch from electric heat pump to boiler operation for consistent comfort.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eThis all-electric system offers reliable year-round comfort and reduced operating costs. It delivers hot water up to 158°F even in low ambient temperatures and 100% heating capacity down to 5° F.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: MITSUBISHI ELECTRIC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: WUZ-SA48NMZ\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeat Pump Type\u003c\/strong\u003e: Air to Water\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHydrobox Mandatory\u003c\/strong\u003e: yes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBTU Size\u003c\/strong\u003e: 48,000 BTU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGas Pipe Size\u003c\/strong\u003e: 5\/8\"\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLiquid Pipe Size\u003c\/strong\u003e: 1\/4\"\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRecommended Fuse\/Breaker Size, ODU + hydrobox (without booster heater)\u003c\/strong\u003e: 40 AMPS\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeating Water Temperature Range [Minimum \/ Maximum]\u003c\/strong\u003e: 77F \/ 158F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Capacity at A45W95\u003c\/strong\u003e: 49,130 BTU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCOP at A45W95\u003c\/strong\u003e: 3.57\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Capacity at A35W95\u003c\/strong\u003e: 49,820 BTU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCOP at A35W95\u003c\/strong\u003e: 2.98\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Capacity at A5W95\u003c\/strong\u003e: 48,450 BTU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCOP at A5W95\u003c\/strong\u003e: 2.14\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Capacity at A5W110\u003c\/strong\u003e: 47,770 BTU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCOP at A5W110\u003c\/strong\u003e: 2.04\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Capacity at A-4W95\u003c\/strong\u003e: 40,263 BTU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCOP at A-4W95\u003c\/strong\u003e: 2.23\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Capacity at A-22W95\u003c\/strong\u003e: 33,438 BTU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCOP at A-22W95\u003c\/strong\u003e: 1.94\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCooling Water Temperature Range [Minimum \/ Maximum]\u003c\/strong\u003e: 41 F\/ 77F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Capacity at A95W45\u003c\/strong\u003e: 42,650 BTU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEER at A95W45\u003c\/strong\u003e: 10.1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Capacity at A95W65\u003c\/strong\u003e: 51,182 BTU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEER at A95W65\u003c\/strong\u003e: 14.19\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRecommended Fuse\/Breaker Size, booster heater (requires separate circuit)\u003c\/strong\u003e: 35 AMPS\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAirflow Rate Cooling CFM\u003c\/strong\u003e: 1,907\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAirflow Rate Heating CFM\u003c\/strong\u003e: 2,119\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSound Pressure Level at A7W55\u003c\/strong\u003e: 45 dB\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Dimensions (W x D x H)\u003c\/strong\u003e: 41-11\/32\" x 18-29\/32\" x 40-15\/16\"\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Weight\u003c\/strong\u003e: 252 lbs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Piping Length [Reversible System]\u003c\/strong\u003e: 164'\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Piping Length [Heating Only System]\u003c\/strong\u003e: 164'\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Height Difference ft\u003c\/strong\u003e: 100'\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Height Difference, ODU above IDU\u003c\/strong\u003e: 100'\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Height Difference, ODU below IDU\u003c\/strong\u003e: 100'\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: ATW\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Heat pump\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003e: WUZ-SA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater heating range\u003c\/strong\u003e: 77°F to 158°F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater cooling range\u003c\/strong\u003e: 41°F to 77°F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCapacity range\u003c\/strong\u003e: 24,000 to 48,000 BTU\/H\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRefrigerant\u003c\/strong\u003e: R32\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"MITSUBISHI ELECTRIC","offers":[{"title":"Default Title","offer_id":51233198145842,"sku":"WUZ-SA48NMZ","price":7896.58,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/307609121.png?v=1780093901","url":"https:\/\/voomisupply.com\/products\/mitsubishi-electric-wuz-sa48nmz-ecodan-air-to-water-heat-pump-48-000-btu","provider":"Voomi Supply","version":"1.0","type":"link"}