{"product_id":"midwest-electric-r281cb1-200a-metered-ringless-panel-1","title":"Midwest Electric r281cb1 200A Metered Ringless Panel","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe MIDWEST ELECTRIC PRODUCTS r281cb1 is a 200-amp, single-phase, metered ringless power outlet panel designed for service entrance applications at residential and light commercial structures. Built from G90 galvanized steel with a zinc-coated finish, it is housed in a NEMA 3R enclosure rated for outdoor use. The unit operates at 120\/240 volts and accepts wire sizes ranging from 6 to 350 KCMIL stranded copper or aluminum at the line meter socket. Surface-mount installation and factory-assembled wiring make this unit suitable for licensed electricians performing new-construction or replacement service entrance work.\u003c\/p\u003e\n\u003cp\u003eThe r281cb1 is intended for outdoor surface-mount installations on single-family residences and mobile homes where the National Electric Code requires service entrance-rated electrical distribution equipment. The cabinet measures 14-3\/8 inches wide, 28-5\/8 inches tall, and 4-3\/4 inches deep, fitting standard surface-mount applications. The first-position circuit breaker type is CB4200H. Multiple wire configurations are supported across load base lug, neutral, and ground positions, accommodating copper and aluminum conductors in both solid and stranded form.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e200-amp current rating with 120\/240-volt, 1-phase circuit configuration\u003c\/li\u003e\n  \u003cli\u003eMetered ringless type design for surface-mount service entrance installations\u003c\/li\u003e\n  \u003cli\u003eG90 galvanized steel construction with zinc-coated finish resists corrosion and fading\u003c\/li\u003e\n  \u003cli\u003eNEMA 3R outdoor-rated enclosure suitable for exposed exterior locations\u003c\/li\u003e\n  \u003cli\u003eAccepts 6 to 350 KCMIL stranded copper or aluminum conductors at the line meter socket\u003c\/li\u003e\n  \u003cli\u003eUL listed and compliant with NEMA and NEC applicable standards\u003c\/li\u003e\n  \u003cli\u003eFactory assembled and wired to reduce installation time and labor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM-style surface-mount service entrance panel for single-family residential and mobile home applications requiring a 200-amp, 1-phase metered ringless configuration per NEC service entrance requirements.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed electrician in accordance with the National Electric Code and applicable local codes. Disconnect and lock out all upstream power sources before beginning any wiring work. The NEMA 3R enclosure requires proper weatherproof conduit fittings at all entry points to maintain its outdoor rating. Verify conductor sizing and termination torque requirements per NEC Article 230 and the equipment labeling before energizing.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e: 200 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e: 120\/240 volts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCircuit Configuration\u003c\/strong\u003e: 1-Phase\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Metered Ringless\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NEMA 3R\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Type\u003c\/strong\u003e: Surface\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCabinet Width\u003c\/strong\u003e: 14-3\/8 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCabinet Height\u003c\/strong\u003e: 28-5\/8 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCabinet Depth\u003c\/strong\u003e: 4-3\/4 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaterial\u003c\/strong\u003e: G90 Galvanized Steel\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFinish\u003c\/strong\u003e: Zinc Coated\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire Size - Line Meter Socket\u003c\/strong\u003e: 6 to 350 KCMIL stranded copper or aluminum\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire Size - Load Base Lug\/Neutral A\u003c\/strong\u003e: 1 to 4 AWG stranded copper or aluminum\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire Size - Neutral\/Ground B\u003c\/strong\u003e: 6 to 2\/0 AWG stranded copper or aluminum\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire Size - Neutral\/Ground C\u003c\/strong\u003e: 14 to 8 AWG solid or 14 to 4 AWG stranded copper\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFirst Position Circuit Breaker Type\u003c\/strong\u003e: CB4200H\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplicable Standards\u003c\/strong\u003e: NEMA, NEC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApproval\u003c\/strong\u003e: UL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: MIDWEST ELECTRIC PRODUCTS\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: r281cb1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MIDWEST ELECTRIC PRODUCTS","offers":[{"title":"Default Title","offer_id":51268185555250,"sku":"R281CB1","price":359.12,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/308912247.jpg?v=1780701596","url":"https:\/\/voomisupply.com\/products\/midwest-electric-r281cb1-200a-metered-ringless-panel-1","provider":"Voomi Supply","version":"1.0","type":"link"}