{"product_id":"mersen-mpdb69153-mpdb-series-power-distribution-block-310a","title":"Mersen MPDB69153 mpdb series power distribution block 310A","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe Mersen MPDB69153 power distribution block provides a safe and easy method of splicing cables and splitting primary power into secondary circuits. It fulfills requirements for fixed junction tap-off points. This large, open-style block is UL and CSA approved, meeting spacing requirements for feeder and branch circuits. It is rated for 600 VAC and 310 A with 3 poles.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eAdder poles can be stacked to form multi-pole units without tools.\u003c\/li\u003e\n  \u003cli\u003eAluminum connectors accept both aluminum or copper wire.\u003c\/li\u003e\n  \u003cli\u003eInsulators are made of virtually unbreakable, glass-filled polycarbonate.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eThis power distribution block features tin-plated aluminum contacts and optional polycarbonate safety covers for dead-front protection.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Mersen\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: MPDB69153\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Mexico\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: MPDB\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e: 600 VAC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e: 310 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e: 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire Size\u003c\/strong\u003e: 6 AWG to 350 kcmil, 14 to 4 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShort Circuit Current Rating\u003c\/strong\u003e: 100 kA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaterial\u003c\/strong\u003e: Polycarbonate\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFinish\u003c\/strong\u003e: TiN Coated\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eColor\u003c\/strong\u003e: Black\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrimary Connections\/Pole\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecondary Connection\/Pole\u003c\/strong\u003e: 12\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplication\u003c\/strong\u003e: Splicing cables Splitting primary power into secondary circuits Fixed junction tap-off points.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Screw\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard\u003c\/strong\u003e: UL Listed to subject 1953, File E352417 unless noted otherwise CSA Certified Class 6228 01\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eItem Type\u003c\/strong\u003e: Open-Style Power Distribution Blocks\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDepth\u003c\/strong\u003e: 3.55 in\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWidth\u003c\/strong\u003e: 7.89 in\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLength\u003c\/strong\u003e: 5.7 in\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFeatures\u003c\/strong\u003e: Flammability Rating 94 V-0; GFPC Insulators; 1 inch through air and 2 inches over surface spacing available\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIncludes\u003c\/strong\u003e: Polycarbonate Safety Covers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMax. Amps\u003c\/strong\u003e: 310 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandards\u003c\/strong\u003e: CSA Class 6228-01, UL 1953\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOverall Depth\u003c\/strong\u003e: 3.55 in\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOverall Width\u003c\/strong\u003e: 7.89 in\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOverall Length\u003c\/strong\u003e: 5.7 in\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS Compliant\u003c\/strong\u003e: Yes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Voltage\u003c\/strong\u003e: 1,000 V AC\/DC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHousing Material\u003c\/strong\u003e: GFPC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Material\u003c\/strong\u003e: Aluminum\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Circuits\u003c\/strong\u003e: 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrimary Wire Range\u003c\/strong\u003e: 6 AWG to 350 kcmil\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLoad Side Wire Range\u003c\/strong\u003e: 14 AWG - 4 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMax. Operating Temp.\u003c\/strong\u003e: 80°C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecondary Wire Range\u003c\/strong\u003e: 14 to 4 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLine Connections\/Pole\u003c\/strong\u003e: 1.0\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLoad Connections\/Pole\u003c\/strong\u003e: 12.0\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFor Conductor Material\u003c\/strong\u003e: Aluminum\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrimary Wire Range (AWG)\u003c\/strong\u003e: 6 AWG to 350 MCM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLine Side Connection Type\u003c\/strong\u003e: Lug\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLine Side Wire Size Range\u003c\/strong\u003e: 6 AWG - 350 kcmil\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLoad Side Connection Type\u003c\/strong\u003e: Lug\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecondary Wire Range (AWG)\u003c\/strong\u003e: 14 to 4 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Distribution Block Design\u003c\/strong\u003e: Open\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Current - Copper Conductor\u003c\/strong\u003e: 310 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFor Line Copper Wire Size - Maximum\u003c\/strong\u003e: 350 kcmil\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFor Line Copper Wire Size - Minimum\u003c\/strong\u003e: 6 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFor Load Copper Wire Size - Maximum\u003c\/strong\u003e: 4 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFor Load Copper Wire Size - Minimum\u003c\/strong\u003e: 14 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Current - Aluminum Conductor\u003c\/strong\u003e: 310 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFor Line Aluminum Wire Size - Maximum\u003c\/strong\u003e: 350 kcmil\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFor Line Aluminum Wire Size - Minimum\u003c\/strong\u003e: 6 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFor Load Aluminum Wire Size - Maximum\u003c\/strong\u003e: 4 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFor Load Aluminum Wire Size - Minimum\u003c\/strong\u003e: 14 AWG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated voltage AC UL\u003c\/strong\u003e: 1000 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated voltage DC UL\u003c\/strong\u003e: 1000 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFrequency (Hz)\u003c\/strong\u003e: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmpere Rating (AL)\u003c\/strong\u003e: 250 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmpere Rating (CU)\u003c\/strong\u003e: 310 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAC or DC\u003c\/strong\u003e: AC\/DC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShort Circuit Rating (Class CC)\u003c\/strong\u003e: 100 kA with 30A Fuse\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShort Circuit Rating (Class G)\u003c\/strong\u003e: 100 kA with 60A Fuse\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShort Circuit Rating (Class J)\u003c\/strong\u003e: 100 kA with 400A Fuse\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShort Circuit Rating (Class L)\u003c\/strong\u003e: 100 kA with 400A Fuse\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShort Circuit Rating (Class RK1)\u003c\/strong\u003e: 100 kA with 200A Fuse\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShort Circuit Rating (Class RK5)\u003c\/strong\u003e: 100 kA with 100A Fuse\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShort Circuit Rating (Standalone)\u003c\/strong\u003e: 10 kA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShort Circuit Rating (Class T)\u003c\/strong\u003e: 100 kA with 400A Fuse\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Openings per Pole (Primary)\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Openings per Pole (Secondary)\u003c\/strong\u003e: 12\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Type (Primary)\u003c\/strong\u003e: Box\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Type (Secondary)\u003c\/strong\u003e: Box\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHex\/Screw Size \u0026amp; Type (Primary)\u003c\/strong\u003e: 11\/16-16 x .88\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHex\/Screw Size \u0026amp; Type (Secondary)\u003c\/strong\u003e: 5\/16-24 x .38\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHole Diameter (Primary)\u003c\/strong\u003e: 0.75 in\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHole Diameter (Secondary)\u003c\/strong\u003e: 0.27 in\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorque Rating (Primary)\u003c\/strong\u003e: 350-#6 275\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorque Rating (Secondary)\u003c\/strong\u003e: #4-#8 40; #10-#14 35\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire Range (Primary)\u003c\/strong\u003e: 350-#6\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWire Range (Secondary)\u003c\/strong\u003e: #4-#14\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInstallation Mounting\u003c\/strong\u003e: Direct Screw Mount\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBody\/Insulating Material\u003c\/strong\u003e: Glass Filled Polycarbonate\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Mersen","offers":[{"title":"Default Title","offer_id":50943979028786,"sku":"MPDB69153","price":441.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/294682358.jpg?v=1772482127","url":"https:\/\/voomisupply.com\/products\/mersen-mpdb69153-mpdb-series-power-distribution-block-310a","provider":"Voomi Supply","version":"1.0","type":"link"}