{"product_id":"lovato-sm1p0400-motor-protection-circuit-breaker-2-5-4a","title":"Lovato SM1P0400 Motor Protection Circuit Breaker 2.5-4A","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe LOVATO SM1P0400 motor protection circuit breaker has an IEC breaking capacity Icu 100kA at 400V, with a thermal trip adjustment range of 2.5...4A. It features both thermal and magnetic trip releases and is phase failure sensitive with an electrical lifespan of 100,000 operations. Suitable for motor protection and mounting in modular panels.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor protection circuit breaker\u003c\/li\u003e\n  \u003cli\u003eIEC breaking capacity Icu 100kA at 400V\u003c\/li\u003e\n  \u003cli\u003eThermal trip adjustment range 2.5...4A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eThe SM1P0400 is versatile with DIN rail mounting, screw terminals, and a pad lockable handle.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: LOVATO\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: SM1P0400\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: ITALY\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct designation\u003c\/strong\u003e: Motor protection circuit breaker\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct type designation\u003c\/strong\u003e: SM1P\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of poles\u003c\/strong\u003e: 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMagnetic protection\u003c\/strong\u003e: yes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal protection\u003c\/strong\u003e: yes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePhase failure detection\u003c\/strong\u003e: yes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated insulation voltage Ui IEC\/EN\u003c\/strong\u003e: 690 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated impulse withstand voltage Uimp\u003c\/strong\u003e: 6 kV\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated frequency\u003c\/strong\u003e: 50\/60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal trip adjustment range\u003c\/strong\u003e: 2.5-4 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated current (In)\u003c\/strong\u003e: 4 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMagnetic tripping\u003c\/strong\u003e: 13 x In\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower dissipation per pole min\u003c\/strong\u003e: 0.90 W\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower dissipation per pole max\u003c\/strong\u003e: 2.29 W\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperational short-circuit current breaking capacity (Ics) at AC 230V\u003c\/strong\u003e: 100 kA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperational short-circuit current breaking capacity (Ics) at AC 400V\u003c\/strong\u003e: 100 kA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperational short-circuit current breaking capacity (Ics) at AC 440V\u003c\/strong\u003e: 100 kA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperational short-circuit current breaking capacity (Ics) at AC 500V\u003c\/strong\u003e: 100 kA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperational short-circuit current breaking capacity (Ics) at AC 690V\u003c\/strong\u003e: 3 kA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum short-circuit current breaking capacity (Icu) at AC 230V\u003c\/strong\u003e: 100 kA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum short-circuit current breaking capacity (Icu) at AC 400V\u003c\/strong\u003e: 100 kA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum short-circuit current breaking capacity (Icu) at AC 440V\u003c\/strong\u003e: 100 kA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum short-circuit current breaking capacity (Icu) at AC 500V\u003c\/strong\u003e: 100 kA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum short-circuit current breaking capacity (Icu) at AC 690V\u003c\/strong\u003e: 3 kA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTripping class\u003c\/strong\u003e: 10A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC Utilization category\u003c\/strong\u003e: A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMechanical life\u003c\/strong\u003e: 100000 cycles\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical life\u003c\/strong\u003e: 100000 cycles\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTightening torque for terminals min\u003c\/strong\u003e: 2.5 Nm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTightening torque for terminals max\u003c\/strong\u003e: 3 Nm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMax number of wires simultaneously connectable\u003c\/strong\u003e: 2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConductor section min\u003c\/strong\u003e: 16 AWG\/Kcmil\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConductor section max\u003c\/strong\u003e: 8 AWG\/Kcmil\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible w\/o lug conductor section min\u003c\/strong\u003e: 1 mm\t00b2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible w\/o lug conductor section max\u003c\/strong\u003e: 10 mm\t00b2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible c\/w lug conductor section min\u003c\/strong\u003e: 1 mm\t00b2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible c\/w lug conductor section max\u003c\/strong\u003e: 10 mm\t00b2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible with insulated spade lug conductor section min\u003c\/strong\u003e: 1 mm\t00b2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible with insulated spade lug conductor section max\u003c\/strong\u003e: 10 mm\t00b2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eScrewdriver\u003c\/strong\u003e: PH2\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower terminal protection according to IEC\/EN 60529\u003c\/strong\u003e: IP20 on front\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable stripping lenght main circuit\u003c\/strong\u003e: 10 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating temperature min\u003c\/strong\u003e: -20 \t00b0C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating temperature max\u003c\/strong\u003e: +60 \t00b0C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStorage temperature min\u003c\/strong\u003e: -50 \t00b0C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStorage temperature max\u003c\/strong\u003e: +80 \t00b0C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompensation temperature min\u003c\/strong\u003e: -20 \t00b0C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompensation temperature max\u003c\/strong\u003e: +50 \t00b0C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMax altitude\u003c\/strong\u003e: 3000 m\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating position normal\u003c\/strong\u003e: Vertical plan\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating position allowable\u003c\/strong\u003e: Any\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFixing\u003c\/strong\u003e: Screw \/ DIN rail 35mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMotor Disconnect at 240V\u003c\/strong\u003e: 30 kA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMotor Disconnect at 480V\u003c\/strong\u003e: 30 kA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMotor Disconnect at 600V\u003c\/strong\u003e: 30 kA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMotor Disconnect protection\u003c\/strong\u003e: 100A class J\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGroup Motor Installation at 240V\u003c\/strong\u003e: 30 kA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGroup Motor Installation at 480V\u003c\/strong\u003e: 30 kA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGroup Motor Installation at 600V\u003c\/strong\u003e: 30 kA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGroup Motor Installation protection\u003c\/strong\u003e: 100A class J\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTap Conductor Protection at 480Y\/277V\u003c\/strong\u003e: 50 kA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTap Conductor Protection at 600Y\/347V\u003c\/strong\u003e: 50 kA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum UL\/CSA horsepower ratings single-phase 110V-120V\u003c\/strong\u003e: 1\/8 HP\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum UL\/CSA horsepower ratings single-phase 220V-240V\u003c\/strong\u003e: 1\/3 HP\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum UL\/CSA horsepower ratings three-phase, 3-pole 200V-208V\u003c\/strong\u003e: 3\/4 HP\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum UL\/CSA horsepower ratings three-phase, 3-pole 220V-240V\u003c\/strong\u003e: 3\/4 HP\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum UL\/CSA horsepower ratings three-phase, 3-pole 440V-480V\u003c\/strong\u003e: 2 HP\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum UL\/CSA horsepower ratings three-phase, 3-pole 550V-600V\u003c\/strong\u003e: 3 HP\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType of product\u003c\/strong\u003e: Motor protection circuit breaker\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType of protection\u003c\/strong\u003e: Magnetic and thermal\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType of control\u003c\/strong\u003e: Push button\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertified UL Type E\u003c\/strong\u003e: No\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAMP range\u003c\/strong\u003e: 2.5 to 4 AMPS\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePhase Loss Protection\u003c\/strong\u003e: Yes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: for DIN rail mounting\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC rated insulation voltage Ui\u003c\/strong\u003e: 690V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC rated impulse withstand voltage\u003c\/strong\u003e: 6kV\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC rated frequency\u003c\/strong\u003e: 50\/60Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum rated current\u003c\/strong\u003e: 40A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdjustment ranges\u003c\/strong\u003e: 16\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeat dissipation per phase\u003c\/strong\u003e: 0.7...3.3W\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePadlocking in OFF\u003c\/strong\u003e: 00d84mm\/0.16\t201d\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC degree of protection\u003c\/strong\u003e: IP20\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Series\u003c\/strong\u003e: SM1P\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFamily Series\u003c\/strong\u003e: Lovato Manual Motor Protectors, SM1P Series\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDescription\u003c\/strong\u003e: Manual Motor Protector, 2.5-4.0A, Pushbutton\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e: 4 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFLA Adjustment Range\u003c\/strong\u003e: 2.5-4\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePhase\u003c\/strong\u003e: 1, 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePoles\u003c\/strong\u003e: 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperator\u003c\/strong\u003e: Push Button\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProtection Rating\u003c\/strong\u003e: IP20\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApprovals\u003c\/strong\u003e: CSA, cULus, EAC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eActuator Type\u003c\/strong\u003e: Pushbutton\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdjustment Range\u003c\/strong\u003e: 2.5-4 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: LOVATO Electric\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e: 100 kA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumeric ID\u003c\/strong\u003e: 4388640\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: SM1P Series\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Thermal\/Magnetic\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating voltage\u003c\/strong\u003e: 230...690V AC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRange of overcurrent release settings\u003c\/strong\u003e: 2.5-4A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical connection\u003c\/strong\u003e: screw terminals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIP rating\u003c\/strong\u003e: IP20\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInsulation voltage\u003c\/strong\u003e: 690V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProtection\u003c\/strong\u003e: anti-overload OPP, short circuit protection SCP\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated surge voltage\u003c\/strong\u003e: 6kV\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting on\u003c\/strong\u003e: 35mm DIN rail (IEC\/EN 60715)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting position\u003c\/strong\u003e: Any\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"LOVATO","offers":[{"title":"Default Title","offer_id":51149623198002,"sku":"SM1P0400","price":70.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/305967455.jpg?v=1778598822","url":"https:\/\/voomisupply.com\/products\/lovato-sm1p0400-motor-protection-circuit-breaker-2-5-4a","provider":"Voomi Supply","version":"1.0","type":"link"}