{"product_id":"icm-controls-292-gas-ignition-control-board-replaces-62-24140-0","title":"Icm Controls 292 Gas Ignition Control Board Replaces 62-24140-0","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe ICM CONTROLS 292 Gas Ignition Control Board is a microprocessor-based direct replacement for furnace ignition systems. It manages inducer motors, air cleaners, humidifiers, spark ignitors, and gas valves. This board monitors timing, trial for ignition, system switches, and flame sensing, ensuring 100% lockout safety. Compatible with LP or Natural Gas, it provides LED indications for status and fault codes, simplifying troubleshooting for various furnace models. It replaces obsolete part number 62-24140-0.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect Spark Ignition (DSI) control board with microprocessor-based operation.\u003c\/li\u003e\n  \u003cli\u003eControls inducer motors, air cleaner, humidifier, spark ignitor, and gas valve.\u003c\/li\u003e\n  \u003cli\u003eMonitors timing, trial for ignition, system switches, flame sensing, and lockout with 100% safety.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eMicroprocessor-based gas ignition control board with LED diagnostics for LP or Natural Gas furnaces.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: ICM CONTROLS\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 292\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel Number\u003c\/strong\u003e: RTG20146\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Type\u003c\/strong\u003e: Panel Mount\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Control Voltage\u003c\/strong\u003e: 24 VAC (18-30 VAC), 60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Line Voltage\u003c\/strong\u003e: 115 VAC, 60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Consumption\u003c\/strong\u003e: 0.3A plus gas valve current at 24 VAC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -40°C (-40°F) to 75°C (176°F)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePre-purge Timing\u003c\/strong\u003e: 30 seconds\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrial for Ignition Timing\u003c\/strong\u003e: 7 seconds\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRetries Timing\u003c\/strong\u003e: Two groups of two, 30 seconds delay within the group and 3 minutes delay between groups\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLockout Timing\u003c\/strong\u003e: 1 hour\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePost-purge Timing\u003c\/strong\u003e: 90, 120, 160 and 180 seconds\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Inputs\u003c\/strong\u003e: 24 VAC and COM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermostat Interface Inputs\u003c\/strong\u003e: R, W, Y and G\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Switches Inputs\u003c\/strong\u003e: Vent Pressure and Limit switches (Main and Over-temperature switches in series)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlame Sensing Input\u003c\/strong\u003e: Yes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeat Blower OFF Delay Input\u003c\/strong\u003e: Miniature slide switch set\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSpark Output\u003c\/strong\u003e: SE\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGas Valve Output\u003c\/strong\u003e: GV\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInducer Draft Motor Output\u003c\/strong\u003e: IDM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBlower Motor Speeds Output\u003c\/strong\u003e: FAN, COOL and HEAT\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectric Air Cleaner Output\u003c\/strong\u003e: EAC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHumidifier Relay Output\u003c\/strong\u003e: HUM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeat\/Cool Relay Output\u003c\/strong\u003e: H\/C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower LED Indicator\u003c\/strong\u003e: PWR (green LED)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStatus LED Indicator\u003c\/strong\u003e: OK (green LED)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlame Status LED Indicator\u003c\/strong\u003e: FLAME (yellow LED)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFuel Compatibility\u003c\/strong\u003e: LP or Natural Gas\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReplaces Part Number\u003c\/strong\u003e: 62-24140-0\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatible Furnace Models\u003c\/strong\u003e: Honeywell, Rheem, Ruud Heat Controller, Weather king (e.g., GLH-06EAUEA, GLH-07EAMGA, GLH-07EAUEA, GLH-10EAMEA, GRA-07EYBG278, GTA-07EYBG278)\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"ICM CONTROLS","offers":[{"title":"Default Title","offer_id":51306721018162,"sku":"292","price":312.86,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/309546371.jpg?v=1781296364","url":"https:\/\/voomisupply.com\/products\/icm-controls-292-gas-ignition-control-board-replaces-62-24140-0","provider":"Voomi Supply","version":"1.0","type":"link"}