{"product_id":"honeywell-s8610u3009-u-universal-intermittent-pilot-ignition-module","title":"Honeywell S8610U3009\/U Universal Intermittent Pilot Ignition Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell S8610U3009\/U is a universal intermittent pilot ignition module. This module provides ignition sequencing, flame monitoring, and safety shutoff for intermittent pilot warm air furnaces and heating appliances. It replaces multiple field-installed intermittent pilot modules and uses an existing intermittent pilot burner.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUniversal intermittent pilot ignition module\u003c\/li\u003e\n  \u003cli\u003eReplaces over 400 White-Rodgers, Robertshaw and Honeywell intermittent pilot ignition modules\u003c\/li\u003e\n  \u003cli\u003eFor use with natural or LP gas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eThe Honeywell S8610U3009\/U intermittent pilot ignition module provides safety and reliability for gas-fired appliances with intermittent pilot ignition systems.\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: HONEYWELL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: S8610U3009\/U\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: United States\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eItem Model Number\u003c\/strong\u003e: S8610U3009\/U\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Honeywell\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: HONEYWELL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Intermittent\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSpecifications\u003c\/strong\u003e: 24 VAC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: MX\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDomestic\/Import\u003c\/strong\u003e: Import\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e: 24 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFrequency Rating\u003c\/strong\u003e: 60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplication\u003c\/strong\u003e: Intermittent Pilot\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Features\u003c\/strong\u003e: For use with natural or LP gas, For use in single rod or dual rod or remote sense applications, Configurable to 30 sec, Universal Pilot Ignition Module, Intermittent, 24 V AC, Replaces over 400 White-Rodgers, Robertshaw and Honeywell intermittent pilot ignition modules, Provides ignition sequencing, flame monitoring and safety shutoff for intermittent pilot warm air furnaces and heating appliances, Provides 100 percent pilot gas shutoff if pilot fails to light after 6 min delay., No prepurge\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApprovals and Standards\u003c\/strong\u003e: CSA: Design Certified\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType of Fuel\u003c\/strong\u003e: Natural Gas, LPG\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgnition Type\u003c\/strong\u003e: Intermittent Pilot\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgnition System Type\u003c\/strong\u003e: Intermittent Pilot\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePilot Type\u003c\/strong\u003e: Intermittent\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgnition Source\u003c\/strong\u003e: Internal high voltage spark generator\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgnition Between Trail Time\u003c\/strong\u003e: 5 minute delay after failed trial for ignition.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgnition Sequence\u003c\/strong\u003e: Continuous Retry\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgnition Trial Time\u003c\/strong\u003e: 15 or 90 seconds\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgnitor Electrical Rating\u003c\/strong\u003e: 24 V AC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgnition Trials To Lockout\u003c\/strong\u003e: continuous retry\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Ignition Trials to Lockout\u003c\/strong\u003e: 0\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePre-Purge\u003c\/strong\u003e: Configurable to 30 sec or no prepurge\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLockout Timing\u003c\/strong\u003e: Continuous Retry\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlame Failure Response Time\u003c\/strong\u003e: 2 seconds maximum\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlame Sense\u003c\/strong\u003e: Two Rod, Single Rod\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEarly Spark Termination\u003c\/strong\u003e: Yes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAuto Reset Delay Timing\u003c\/strong\u003e: 1 min\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermostat Anticipator Rating\u003c\/strong\u003e: 0.2 A plus pilot valve rating plus main valve rating\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCurrent Draw\u003c\/strong\u003e: 1 A Pilot Valve|2 A Main Valve\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Consumption\u003c\/strong\u003e: 2 VA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLoad Relay Rating\u003c\/strong\u003e: 24 V AC (Amps) 1 A  Pilot, 2 A Main at 165 \t00b0F, 1A Pilot, 1A Main at 175 \t00b0F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTypical Ignition Hardware\u003c\/strong\u003e: Q345, Q3451, Q3452\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgniter-Sensor Rod\u003c\/strong\u003e: Dual, Single\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTypical Gas Control\u003c\/strong\u003e: VR8204, VR8304\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Depth\u003c\/strong\u003e: 2.63 in, 67mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Valve Load\u003c\/strong\u003e: 1 A Pilot, 2A Main @ 165 \t00b0F, 1 A Pilot, 1A Main @ 175 \t00b0F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply Frequency\u003c\/strong\u003e: 60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFrequency\u003c\/strong\u003e: 60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 24 V AC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatible With\u003c\/strong\u003e: Intermittent pilot warm air furnaces and heating appliances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFor Use With\u003c\/strong\u003e: Q345, Q348, Q362, Q373, Q381, Q179C, Q354,  Q345, Q348,  Q362, Q373, Q381\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDo Not Use With\u003c\/strong\u003e: Do Not Use the 24 V Terminal on S8610U\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIncludes\u003c\/strong\u003e: Spark cable adapters to allow field replacement of both Resideo and competitive controls without replacing existing spark cable\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Height\u003c\/strong\u003e: 3.94 in, 100 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct Width\u003c\/strong\u003e: 5.44 in, 138 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmbient Operating Temperature (Max)\u003c\/strong\u003e: 165 \t00b0F, 74 \t00b0C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmbient Operating Temperature (Min)\u003c\/strong\u003e: -40 \t00b0F, -40 \t00b0C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBetween Trial Time (sec)\u003c\/strong\u003e: 5 minute delay after failed trial for ignition.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical Ratings\u003c\/strong\u003e: 24 Vac\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTradeline Value\u003c\/strong\u003e: Tradeline\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmbient Temperature Range (F)\u003c\/strong\u003e: -40 F to +165 F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType of Gas\u003c\/strong\u003e: Natural or LP\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlame Failure Response Time (sec)\u003c\/strong\u003e: 2 seconds maximum\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApprovals\u003c\/strong\u003e: Canadian Standards Association\",Design Certified\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgnition Trial Time (sec)\u003c\/strong\u003e: 15 or 90 sec\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Valve Load @ 24 Vac (Amps)\u003c\/strong\u003e: 1A Pilot, 2A Main @ 165 F; 1A Pilot, 1A Main @ 175 F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions (in.)\u003c\/strong\u003e: 3 15\/16 in. high x 5 7\/16 in. wide x 2 5\/8 in. deep\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmbient Temperature Range (C)\u003c\/strong\u003e: -40 C to +74 C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eItem Type\u003c\/strong\u003e: Product\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions (mm)\u003c\/strong\u003e: 100 mm high x 138 mm wide x 67 mm deep\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"HONEYWELL","offers":[{"title":"Default Title","offer_id":51205671878962,"sku":"S8610U3009\/U","price":186.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/307140022.jpg?v=1779717741","url":"https:\/\/voomisupply.com\/products\/honeywell-s8610u3009-u-universal-intermittent-pilot-ignition-module","provider":"Voomi Supply","version":"1.0","type":"link"}