{"product_id":"honeywell-c6097a1228-u-gas-air-pressure-switch-manual-reset","title":"Honeywell c6097a1228\/u Gas Air Pressure Switch Manual Reset","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\u003cp\u003eThe HONEYWELL c6097a1228\/u is a diaphragm-actuated safety-limit pressure switch designed for positive-pressure and differential-pressure systems handling natural gas, liquid propane (LP) gas, or air. It features a manual reset lockout with an external reset button and a switching action that breaks the control circuit on pressure fall. The operating range spans 0.4 to 5 inches water column (in. wc), with a maximum differential pressure of 0.6 in. wc at minimum setpoint and 0.25 in. wc at maximum setpoint. An IP54-rated enclosure protects internal components. Licensed HVAC technicians and gas systems professionals are the primary installers of this switch.\u003c\/p\u003e\u003cp\u003eThis pressure switch is used as a safety device in residential and commercial combustion and air-handling systems where gas or air pressure must be continuously monitored. It mounts via flange directly to compatible valve train assemblies. The switch can be wired to trigger an alarm condition. A removable transparent cover protects the scaleplate and adjusting knob during field service. The integral vent limiter and surge orifice are standard on this model. Pipe tappings support vent or low-pressure connections via 1\/8 in. NPT internal thread.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eDiaphragm-actuated safety-limit switch breaks control circuit on pressure fall\u003c\/li\u003e\n\u003cli\u003eManual reset lockout with external reset button for positive safety confirmation\u003c\/li\u003e\n\u003cli\u003eOperating range of 0.4 to 5 in. wc with additive differential pressure action\u003c\/li\u003e\n\u003cli\u003eIP54 enclosure with removable transparent cover protecting scaleplate and adjusting knob\u003c\/li\u003e\n\u003cli\u003eIntegral vent limiter and surge orifice standard on all models\u003c\/li\u003e\n\u003cli\u003eScrew terminal electrical connections rated for 120 Vac and 240 Vac service\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\u003cp\u003eDesigned for flange-mount installation in positive-pressure or differential-pressure systems using natural gas, LP gas, or air. Compatible with Honeywell Integrated Valve Train assemblies via direct flange mounting.\u003c\/p\u003e\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\u003cp\u003eInstallation should be performed by a licensed HVAC technician or qualified gas systems professional in accordance with applicable local codes and the International Fuel Gas Code (IFGC). Shut off all gas supply and de-energize the system before servicing or replacing the switch. Verify correct switching action and reset behavior after installation before returning the system to service. Do not bypass the manual reset function under any circumstances.\u003c\/p\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitch Operation\u003c\/strong\u003e: Manual Reset\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Action\u003c\/strong\u003e: Break on pressure fall\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Range\u003c\/strong\u003e: 0.4 to 5 in. wc (0.10 to 1.25 kPa)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDifferential Pressure Range\u003c\/strong\u003e: Max 0.6 in. wc at minimum setpoint; max 0.25 in. wc at maximum setpoint\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDifferential Type\u003c\/strong\u003e: Additive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Rating at 120 Vac\u003c\/strong\u003e: 3.0 AFL, 18.0 ALR, 5.0 A resistive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Rating at 240 Vac\u003c\/strong\u003e: 3.0 AFL, 18.0 ALR, 5.0 A resistive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition Transformer Rating\u003c\/strong\u003e: 540 VA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePilot Valve Rating\u003c\/strong\u003e: 50 VA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain Valve Rating\u003c\/strong\u003e: 400 VA with 2.5 times inrush\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e: -40 degrees F to 140 degrees F (-40 degrees C to 60 degrees C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e: IP54\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Flange Mount\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePipe Connection\u003c\/strong\u003e: 1\/8 in. NPT internal thread (vent or low pressure)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Connections\u003c\/strong\u003e: Screw terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e: 3.53 inches high x 2.72 inches wide x 2.72 inches deep\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight\u003c\/strong\u003e: 3.31 pounds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals\u003c\/strong\u003e: UL Component Listed MP 2168-8-1; CSA File 95329 Certificate 2632-01; FM JI 2D4A1.AF; Swiss RE Acceptable; CSD-1 AFB Acceptable\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandard Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: HONEYWELL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: c6097a1228\/u\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HONEYWELL","offers":[{"title":"Default Title","offer_id":51467403362610,"sku":"C6097A1228\/U","price":139.39,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/313946033.png?v=1783903604","url":"https:\/\/voomisupply.com\/products\/honeywell-c6097a1228-u-gas-air-pressure-switch-manual-reset","provider":"Voomi Supply","version":"1.0","type":"link"}