{"product_id":"heat-controller-mcr030ahc30c0ps-heat-pump-2-5-ton","title":"Heat Controller MCR030AHC30C0PS Heat Pump 2.5 Ton","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe HEAT CONTROLLER MCR030AHC30C0PS is a 2.5-ton horizontal water source heat pump designed for three-phase commercial and residential applications operating at 208\/230 volts. It uses R-454B refrigerant and delivers a ground water cooling capacity of 32,400 BTU\/h at 59 degrees F entering water temperature (EWT) and a heating capacity of 29,200 BTU\/h at 50 degrees F EWT. A ground water coefficient of performance (COP) of 4.1 and an EER of 21 both exceed ASHRAE 90.1 efficiency standards. The unit features a coaxial heat exchanger and a built-in performance monitoring system that signals potential issues before they become failures. Licensed HVAC technicians install this unit in commercial light construction and retrofit scenarios where horizontal clearance is available but vertical space is limited.\u003c\/p\u003e\n\u003cp\u003eThe MCR030AHC30C0PS is suited for water loop and ground water hydronic heat pump systems in commercial buildings, hotels, multi-family residential, and similar applications where centralized loop water is available. In water loop mode, the unit delivers 28,800 BTU\/h of cooling at 86 degrees F EWT and 35,400 BTU\/h of heating at 68 degrees F EWT, with a water loop COP of 4.6 and a water loop EER of 13.7. The right-return air configuration and compact horizontal profile make this unit practical for above-ceiling, mechanical closet, or in-wall chase installations where space is constrained. It is an appropriate choice for new construction and retrofit projects alike.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e2.5-ton nominal capacity in a compact horizontal configuration ideal for tight or retrofit spaces\u003c\/li\u003e\n  \u003cli\u003eGround water EER of 21 and COP of 4.1 exceed ASHRAE 90.1 efficiency requirements\u003c\/li\u003e\n  \u003cli\u003eR-454B refrigerant with extended-range refrigerant circuit for broader operating conditions\u003c\/li\u003e\n  \u003cli\u003eCoaxial heat exchanger for reliable water-to-refrigerant heat transfer\u003c\/li\u003e\n  \u003cli\u003eIntegrated performance monitoring system alerts technicians to potential faults early\u003c\/li\u003e\n  \u003cli\u003eThree-phase 208\/230V power supply suits commercial electrical infrastructure\u003c\/li\u003e\n  \u003cli\u003eRight return air configuration supports common horizontal duct layouts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM water source heat pump for horizontal hydronic loop systems requiring a 2.5-ton three-phase unit at 208\/230 volts using R-454B refrigerant.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed HVAC technician familiar with hydronic heat pump systems and local mechanical codes. Shut off loop water flow and de-energize all electrical circuits before servicing or connecting the unit. Refrigerant handling requires EPA Section 608 certification due to the use of R-454B. Verify that loop water quality, flow rate, and entering water temperature are within the manufacturer-specified operating range before startup.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNominal Capacity\u003c\/strong\u003e: 2.5 tons\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePhase\u003c\/strong\u003e: Three\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 208\/230 volts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRefrigerant\u003c\/strong\u003e: R-454B\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGround Water Cooling Capacity (59 degrees F EWT)\u003c\/strong\u003e: 32,400 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGround Water Heating Capacity (50 degrees F EWT)\u003c\/strong\u003e: 29,200 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGround Water EER\u003c\/strong\u003e: 21\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGround Water COP\u003c\/strong\u003e: 4.1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater Loop Cooling Capacity (86 degrees F EWT)\u003c\/strong\u003e: 28,800 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater Loop Heating Capacity (68 degrees F EWT)\u003c\/strong\u003e: 35,400 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater Loop EER\u003c\/strong\u003e: 13.7\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater Loop COP\u003c\/strong\u003e: 4.6\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeat Exchanger Type\u003c\/strong\u003e: Coaxial, Standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReturn Air Option\u003c\/strong\u003e: Right\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOrientation\u003c\/strong\u003e: Horizontal\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShipping Weight\u003c\/strong\u003e: 187 pounds\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShipping Dimensions\u003c\/strong\u003e: 43 inches L x 20.1 inches W x 18.3 inches H\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: HEAT CONTROLLER\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: MCR030AHC30C0PS\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HEAT CONTROLLER","offers":[{"title":"Default Title","offer_id":51346829607218,"sku":"MCR030AHC30C0PS","price":5416.76,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/renderImage_fd616e61-dbaf-44f8-ab94-54ad8f373666.jpg?v=1782091641","url":"https:\/\/voomisupply.com\/products\/heat-controller-mcr030ahc30c0ps-heat-pump-2-5-ton","provider":"Voomi Supply","version":"1.0","type":"link"}