{"product_id":"heat-controller-mcl024afc30c0ps-heat-pump-2-ton-460v","title":"Heat Controller MCL024AFC30C0PS Heat Pump 2 Ton 460V","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe HEAT CONTROLLER MCL024AFC30C0PS is a horizontal water source heat pump rated at 2 nominal tons and designed for three-phase, 460-volt electrical service. It uses R-454B refrigerant and delivers both heating and cooling through a coaxial heat exchanger that transfers energy between the refrigerant circuit and the water loop or ground water source. Cooling capacity reaches 27,500 BTU\/h at 59 degrees F entering water temperature (EWT) in ground water mode, while heating output reaches 24,200 BTU\/h at 50 degrees F EWT. The unit exceeds ASHRAE 90.1 efficiency standards and includes a performance monitoring system that signals potential equipment issues before they escalate. Licensed HVAC technicians install and service this equipment.\u003c\/p\u003e\n\u003cp\u003eThis unit is built for horizontal installation in commercial and light-commercial buildings where ceiling plenum or mechanical closet space is limited. The compact footprint makes it well suited for retrofit projects and tight mechanical spaces. Return air is configured for left-side entry. It operates effectively in both water loop heat pump systems and ground water heat pump systems, making it adaptable to a range of hydronic system designs commonly found in multi-tenant commercial buildings, hotels, and office applications.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eGround water cooling: 27,500 BTU\/h at 59 degrees F EWT with EER of 23.3\u003c\/li\u003e\n  \u003cli\u003eGround water heating: 24,200 BTU\/h at 50 degrees F EWT with COP of 4.4\u003c\/li\u003e\n  \u003cli\u003eWater loop cooling: 24,700 BTU\/h at 86 degrees F EWT with EER of 14.7\u003c\/li\u003e\n  \u003cli\u003eWater loop heating: 28,800 BTU\/h at 68 degrees F EWT with COP of 5.0\u003c\/li\u003e\n  \u003cli\u003eExceeds ASHRAE 90.1 efficiency standards with R-454B refrigerant\u003c\/li\u003e\n  \u003cli\u003ePerformance monitoring system provides early fault indication\u003c\/li\u003e\n  \u003cli\u003eCompact horizontal design suited for retrofit and tight-space installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned for use in horizontal water source heat pump systems operating on three-phase, 460-volt power with R-454B refrigerant, including ground water and closed-loop water loop applications in commercial environments.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation and commissioning must be performed by a licensed HVAC technician familiar with water source heat pump systems and local mechanical codes. Disconnect and lock out all electrical power and isolate the water loop before servicing. Verify that the supply water temperature, flow rate, and system pressure are within the equipment design range before startup. Follow all applicable local, state, and national codes including ASHRAE standards and refrigerant handling requirements under EPA Section 608.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNominal Capacity\u003c\/strong\u003e: 2 tons\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePhase\u003c\/strong\u003e: Three-phase\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 460 volts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRefrigerant\u003c\/strong\u003e: R-454B\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOrientation\u003c\/strong\u003e: Horizontal\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReturn Air Option\u003c\/strong\u003e: Left\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeat Exchanger\u003c\/strong\u003e: Coaxial, Standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGround Water Cooling Capacity (59 degrees F EWT)\u003c\/strong\u003e: 27,500 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGround Water Cooling EER\u003c\/strong\u003e: 23.3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGround Water Heating Capacity (50 degrees F EWT)\u003c\/strong\u003e: 24,200 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGround Water Heating COP\u003c\/strong\u003e: 4.4\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater Loop Cooling Capacity (86 degrees F EWT)\u003c\/strong\u003e: 24,700 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater Loop Cooling EER\u003c\/strong\u003e: 14.7\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater Loop Heating Capacity (68 degrees F EWT)\u003c\/strong\u003e: 28,800 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater Loop Heating COP\u003c\/strong\u003e: 5.0\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShipping Weight\u003c\/strong\u003e: 179 pounds\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShipping Length\u003c\/strong\u003e: 43 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShipping Width\u003c\/strong\u003e: 20.1 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShipping Height\u003c\/strong\u003e: 18.3 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: HEAT CONTROLLER\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: MCL024AFC30C0PS\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HEAT CONTROLLER","offers":[{"title":"Default Title","offer_id":51344939974962,"sku":"MCL024AFC30C0PS","price":5110.64,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/renderImage_099bf016-faf3-47e1-934a-cf626857566d.jpg?v=1782046221","url":"https:\/\/voomisupply.com\/products\/heat-controller-mcl024afc30c0ps-heat-pump-2-ton-460v","provider":"Voomi Supply","version":"1.0","type":"link"}