{"product_id":"heat-controller-hbv024a1c30cct-water-source-heat-pump-2-ton","title":"Heat Controller HBV024A1C30CCT Water Source Heat Pump 2 Ton","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe HEAT CONTROLLER HBV024A1C30CCT is a 2-ton vertical water source heat pump designed for single-phase electrical service at 208\/230 volts using R410A refrigerant. It delivers both heating and cooling through a refrigerant-to-water heat exchange process, making it suitable for water loop and ground water hydronic systems. The unit features a heavy-duty scroll compressor and an extended range refrigerant circuit. A built-in performance monitoring system flags potential faults before they escalate. Licensed HVAC technicians install and commission this equipment in commercial and residential hydronic applications.\u003c\/p\u003e\n\u003cp\u003eThis unit is sized for installations where floor space is limited. Its vertical cabinet orientation and compact footprint make it well suited for retrofit applications, utility closets, and mechanical rooms where ceiling height is available but square footage is not. The right-side return air configuration supports specific ductwork layouts common in these scenarios. The copper water coil with non-coated air coil heat exchanger handles both water loop and ground water source configurations, giving contractors flexibility across project types.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eHeavy-duty scroll compressor for reliable, long-cycle operation\u003c\/li\u003e\n  \u003cli\u003eExtended range refrigerant circuit supports ground water and water loop applications\u003c\/li\u003e\n  \u003cli\u003ePerformance monitoring system provides early fault signaling\u003c\/li\u003e\n  \u003cli\u003eCompact vertical cabinet designed for tight spaces and retrofit installs\u003c\/li\u003e\n  \u003cli\u003eCopper water coil with non-coated air coil heat exchanger\u003c\/li\u003e\n  \u003cli\u003eRight return air configuration for duct layout flexibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned for use in water loop and ground water source heat pump systems. Suitable for single-phase 208\/230V hydronic HVAC installations in residential and light commercial applications requiring a 2-ton vertical unit with right return air orientation.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed HVAC technician familiar with hydronic heat pump systems and local mechanical codes. Disconnect all electrical power and isolate the water loop before beginning any service or installation work. Ensure proper water flow rates are established and verified at startup, as insufficient flow can damage the heat exchanger. Refrigerant handling requires EPA Section 608 certification.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNominal Capacity\u003c\/strong\u003e: 2 tons\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePhase\u003c\/strong\u003e: Single\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 208\/230 volts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRefrigerant\u003c\/strong\u003e: R410A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCabinet Orientation\u003c\/strong\u003e: Vertical\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReturn Air Option\u003c\/strong\u003e: Right\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater Loop Cooling Capacity (86 degrees F EWT)\u003c\/strong\u003e: 23,600 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater Loop Heating Capacity (68 degrees F EWT)\u003c\/strong\u003e: 27,500 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater Loop EER\u003c\/strong\u003e: 13\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater Loop COP\u003c\/strong\u003e: 4.6\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGround Water Cooling Capacity (59 degrees F EWT)\u003c\/strong\u003e: 27,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGround Water Heating Capacity (50 degrees F EWT)\u003c\/strong\u003e: 23,500 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGround Water EER\u003c\/strong\u003e: 20.5\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGround Water COP\u003c\/strong\u003e: 4.1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeat Exchanger\u003c\/strong\u003e: Copper Water Coil with Non-Coated Air Coil\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHot Water Generator\u003c\/strong\u003e: No\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShipping Weight\u003c\/strong\u003e: 194 pounds\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShipping Dimensions\u003c\/strong\u003e: 21.5 inches W x 21.5 inches L x 40 inches H\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: HEAT CONTROLLER\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: HBV024A1C30CCT\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HEAT CONTROLLER","offers":[{"title":"Default Title","offer_id":51346555765042,"sku":"HBV024A1C30CCT","price":5060.54,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/renderImage_225f9e2e-dc17-4b31-a8bb-f22b2ae15191.jpg?v=1782083753","url":"https:\/\/voomisupply.com\/products\/heat-controller-hbv024a1c30cct-water-source-heat-pump-2-ton","provider":"Voomi Supply","version":"1.0","type":"link"}