{"product_id":"hearthrite-hbw30tl-30000-btu-vent-free-blue-flame-lp-heater","title":"Hearthrite HBW30TL 30000 Btu Vent Free Blue Flame Lp Heater","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\u003cp\u003eThe HEARTHRITE HBW30TL is a 30,000 BTU\/h vent-free blue flame gas heater designed for liquid propane (LP) operation in residential and light commercial spaces. Blue flame technology heats air directly, allowing natural convection to distribute warmth throughout the room. The unit operates at 99.9% AFUE efficiency and runs without electrical power, making it reliable during outages. A built-in Oxygen Depletion Sensor (ODS) automatically shuts the heater down before oxygen levels reach an unsafe threshold. Thermostatic control maintains consistent room temperature. Installation is handled by a licensed or certified gas technician.\u003c\/p\u003e\u003cp\u003eThe HBW30TL is suited for living rooms, garages, workshops, and supplemental heating zones where a vent pipe is not practical or available. It mounts to a wall using the included wall kit or can be floor-mounted with the optional floor stand kit. LP models must be connected to a tank of 100 lbs or larger with an external regulator supplying 11 to 14 inches water column (w.c.) inlet pressure. A matching natural gas version, the HBW30TN, is also available. This product cannot be shipped to California.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e30,000 BTU\/h blue flame output with 99.9% AFUE efficiency rating\u003c\/li\u003e\n\u003cli\u003eVent-free design eliminates the need for flue or exhaust piping\u003c\/li\u003e\n\u003cli\u003eOxygen Depletion Sensor shuts off the unit before unsafe oxygen depletion occurs\u003c\/li\u003e\n\u003cli\u003ePushbutton piezo ignition with standing pilot — operates without electrical power\u003c\/li\u003e\n\u003cli\u003eThermostatic control for automatic temperature regulation\u003c\/li\u003e\n\u003cli\u003eFactory test-fired before shipment; wall mount kit included, floor stand optional\u003c\/li\u003e\n\u003cli\u003eOptional blower available separately to improve air distribution\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\u003cp\u003eDesigned for use with liquid propane gas systems. Requires a 100 lb or larger LP tank and an external regulator with an output of 11 to 14 inches w.c. A natural gas variant (HBW30TN) is available separately. Not approved for installation in the state of California.\u003c\/p\u003e\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\u003cp\u003eInstallation must be performed by a certified gas technician in accordance with local codes and applicable standards. Before servicing or connecting gas supply, shut off the gas at the supply valve and verify zero pressure in the line. Maintain required clearances: 36 inches to the ceiling above, 3 inches to the floor below, and 8 inches to any side wall. All repairs must be performed by a qualified service contractor — do not attempt field modifications to the gas valve, ODS, or pilot assembly.\u003c\/p\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Capacity\u003c\/strong\u003e: 30,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAFUE Efficiency\u003c\/strong\u003e: 99.9%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel Type\u003c\/strong\u003e: Liquid Propane (LP)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlame Type\u003c\/strong\u003e: Blue Flame\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition Type\u003c\/strong\u003e: Standing Pilot with Pushbutton Piezo\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Type\u003c\/strong\u003e: Thermostatic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVenting Type\u003c\/strong\u003e: Vent Free\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Connection Size\u003c\/strong\u003e: 3\/8 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManifold Pressure\u003c\/strong\u003e: 9.0 inches w.c.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInlet Gas Pressure (Min.)\u003c\/strong\u003e: 11 inches w.c.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInlet Gas Pressure (Max.)\u003c\/strong\u003e: 14 inches w.c.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Type\u003c\/strong\u003e: Floor or Wall Mount\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearance — Top to Ceiling\u003c\/strong\u003e: 36 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearance — Bottom to Floor\u003c\/strong\u003e: 3 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearance — To Side Wall\u003c\/strong\u003e: 8 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth\u003c\/strong\u003e: 27.16 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth\u003c\/strong\u003e: 7.44 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight\u003c\/strong\u003e: 23 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight\u003c\/strong\u003e: 24.2 pounds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications\u003c\/strong\u003e: AHRI, Design Certified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower\u003c\/strong\u003e: Optional (sold separately)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandard Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: HEARTHRITE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: HBW30TL\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HEARTHRITE","offers":[{"title":"Default Title","offer_id":51284040876338,"sku":"HBW30TL","price":790.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/309279870.jpg?v=1781066939","url":"https:\/\/voomisupply.com\/products\/hearthrite-hbw30tl-30000-btu-vent-free-blue-flame-lp-heater","provider":"Voomi Supply","version":"1.0","type":"link"}