{"product_id":"hammond-power-solutions-q002lekf-2-kva-240-x-480-volt-primary-120-240-volt-secondary-1-phase-encapsulated-transformer","title":"Hammond Power Solutions Q002LEKF 2 kVa 240 x 480 Volt Primary 120\/240 Volt Secondary 1-Phase Encapsulated Transformer","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe HAMMOND POWER Solutions Q002LEKF is an HPS Titan encapsulated transformer designed for harsh environments and hazardous locations where gases, liquids, and dust could lead to serious consequences. It features an ANSI 61 grey, UL50 heavy-duty NEMA type 3R enclosure and standard wall mounting. Typical applications include institutional, commercial, industrial, petrochemical, marine, and mining.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eHPS Titan encapsulated transformer\u003c\/li\u003e\n  \u003cli\u003eDesigned to operate in harsh environments\/hazardous locations\u003c\/li\u003e\n  \u003cli\u003eANSI 61 grey, UL50 heavy duty NEMA type 3R enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProduct Highlights\u003c\/h4\u003e\n\u003cp\u003eThis encapsulated transformer is ideal for use in demanding conditions\u003c\/p\u003e\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: HAMMOND POWER Solutions\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: Q002LEKF\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: United States\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Transformer \u0026gt; Distribution \u0026gt; Potted \u0026gt; Hazardous Location \u0026gt; Single Phase\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Hammond Power Solutions\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWidth\u003c\/strong\u003e: 7 in\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeight\u003c\/strong\u003e: 11-3\/4 Inch\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLength\u003c\/strong\u003e: 6-1\/2 Inch\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWattage\u003c\/strong\u003e: 2000 Watt\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnclosure\u003c\/strong\u003e: NQ4-N3R - Indoor or Outdoor\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFrequency\u003c\/strong\u003e: 60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSub Brand\u003c\/strong\u003e: Industrial Potted Transformer\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct UPC\u003c\/strong\u003e: 80342303295\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e12-Digit UPC\u003c\/strong\u003e: 803423032951\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplications\u003c\/strong\u003e: Petrochemical, Marine, Industrial, Oil \u0026amp; gas, Mining, Waste Water\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e: 240X480 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e: 120\/240 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature Rating\u003c\/strong\u003e: 40 C\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration\u003c\/strong\u003e: Encapsulated\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: Q002LEKF\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Rating\u003c\/strong\u003e: 2 kVA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrimary Type\u003c\/strong\u003e: Industrial Transformer\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: Universal Series\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUPC Code\u003c\/strong\u003e: 803423032951\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePhase\u003c\/strong\u003e: Single Phase\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrimary Voltage\u003c\/strong\u003e: 240x480V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVA\u003c\/strong\u003e: 2000VA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInsulation System\u003c\/strong\u003e: 130°C (80°C rise) standard on all units\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEncapsulation\u003c\/strong\u003e: All units are encapsulated with electrical grade silica sand and resin compounds\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnclosure Type\u003c\/strong\u003e: Heavy duty type 3R, optional type 4, 4X (stainless steel) and 12\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTermination\u003c\/strong\u003e: Front accessible separate high and low voltage lead wires or copper tabs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConduit Knock-Outs\u003c\/strong\u003e: Standard side and rear knock-outs on all units (no knock-outs on Stainless Steel enclosures)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Standard Wall Mounting, Lifting provisions standard on all units\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSeismic\u003c\/strong\u003e: Seismically certified in accordance with IBC 2009; Section 1613 Earthquake Loads, for SDS \u0026lt;= 2.00g, z\/h = 1.0, and IP = 1.5\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVolt Amps\u003c\/strong\u003e: 2kVA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003etype_updatedforcompatibility\u003c\/strong\u003e: Distribution\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eva_rating\u003c\/strong\u003e: 2,000 VA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eprimary_voltage\u003c\/strong\u003e: 240 V, 480 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003esecondary_voltage\u003c\/strong\u003e: 120 V, 240 V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eenclosed\u003c\/strong\u003e: Yes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eprimary_fuseholder\u003c\/strong\u003e: Not Available\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003esecondary_fuseholder\u003c\/strong\u003e: Not Available\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003enema_rating\u003c\/strong\u003e: NEMA 3R\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003einsulation_class\u003c\/strong\u003e: Class B\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003etemperature_rise_f\u003c\/strong\u003e: 176 °F\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"HAMMOND POWER Solutions","offers":[{"title":"Default Title","offer_id":51036497248562,"sku":"Q002LEKF","price":988.4,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/299940535.jpg?v=1775195442","url":"https:\/\/voomisupply.com\/products\/hammond-power-solutions-q002lekf-2-kva-240-x-480-volt-primary-120-240-volt-secondary-1-phase-encapsulated-transformer","provider":"Voomi Supply","version":"1.0","type":"link"}