{"product_id":"goodman-arvt800804cn-80-afue-gas-furnace-80000-btu-h","title":"Goodman arvt800804cn 80 Afue Gas Furnace 80000 Btu\/h","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe GOODMAN arvt800804cn is an 80 AFUE two-stage, variable-speed ECM upflow\/horizontal gas furnace rated at 80,000 BTU\/h high-fire input and 64,000 BTU\/h high-fire output. It runs a 56,000 BTU\/h low-fire input stage for quieter, more efficient part-load operation. The variable-speed blower motor delivers airflow from 1,090 to 1,400 cubic feet per minute across heating stages, reducing temperature swings and improving comfort. Powered at 115 volts, 60 Hz, single phase, the unit draws a minimum of 7.75 amps with a 15-amp maximum overcurrent protection rating. Licensed HVAC technicians perform installation in residential and light-commercial applications.\u003c\/p\u003e\n\u003cp\u003eThis furnace is configured for upflow or horizontal installation, making it suitable for basement, closet, attic, or crawlspace applications where the air handler sits above or alongside the living space. The two-stage gas valve reduces input to 56,000 BTU\/h on low fire, cutting cycling and noise during mild weather. The non-NOx burner design meets low-emissions requirements in regulated markets. With a nominal cooling capacity pairing of 48,000 BTU\/h (4 tons), this unit is sized to match a 4-ton cooling coil in a split system. The communication feature allows integration with compatible communicating thermostats and controls.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e80 AFUE efficiency with two-stage gas valve for low-fire input of 56,000 BTU\/h and high-fire input of 80,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003eVariable-speed ECM blower motor at up to 1,200 RPM with 11-inch diameter, 10-inch wide blower wheel\u003c\/li\u003e\n  \u003cli\u003eUpflow\/horizontal installation configuration for flexible placement\u003c\/li\u003e\n  \u003cli\u003eNon-NOx burner design for compliance in low-emissions jurisdictions\u003c\/li\u003e\n  \u003cli\u003eCommunication-capable for use with compatible communicating system controls\u003c\/li\u003e\n  \u003cli\u003eETL Listed and ANSI Certified\u003c\/li\u003e\n  \u003cli\u003eTemperature rise range of 25-55 degrees F on high fire and 20-50 degrees F on low fire\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as an OEM upflow\/horizontal gas furnace for pairing with a 4-ton (48,000 BTU\/h nominal) cooling coil in a split-system configuration. Specific compatible coil and air handler model numbers were not provided in the product data; consult the manufacturer documentation to confirm matched-system pairings.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed HVAC technician in accordance with local mechanical codes, the National Fuel Gas Code (NFPA 54\/ANSI Z223.1), and the manufacturer installation instructions. Shut off gas supply and disconnect electrical power before servicing or connecting the unit. Maintain a minimum 1-foot clearance to combustible materials on all applicable sides as specified. The 4-inch vent diameter connection requires a properly sized venting system; verify vent material compatibility and local code requirements before installation.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAFUE\u003c\/strong\u003e: 80\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Fire Input Capacity\u003c\/strong\u003e: 80,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Fire Output Capacity\u003c\/strong\u003e: 64,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLow-Fire Input Capacity\u003c\/strong\u003e: 56,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLow-Fire Output Capacity\u003c\/strong\u003e: 44,800 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNominal Cooling Capacity Pairing\u003c\/strong\u003e: 48,000 BTU\/h (4 tons)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGas Valve Type\u003c\/strong\u003e: Two Stage\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMotor Speed Type\u003c\/strong\u003e: Variable Speed ECM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBlower Motor Horsepower\u003c\/strong\u003e: 1\/2 hp\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBlower Motor RPM\u003c\/strong\u003e: 1,200 RPM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBlower Diameter\u003c\/strong\u003e: 11 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBlower Width\u003c\/strong\u003e: 10 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAir Flow Rate High Fire\u003c\/strong\u003e: 1,400 ft3\/min\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAir Flow Rate Low Fire\u003c\/strong\u003e: 1,090 ft3\/min\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature Rise Range High Fire\u003c\/strong\u003e: 25-55 degrees F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature Rise Range Low Fire\u003c\/strong\u003e: 20-50 degrees F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Voltage\u003c\/strong\u003e: 115 volts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Frequency\u003c\/strong\u003e: 60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Phase\u003c\/strong\u003e: 1 Ph\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimum Circuit Amps\u003c\/strong\u003e: 7.75 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMax Overcurrent Protection\u003c\/strong\u003e: 15 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExternal Static Pressure Rated\u003c\/strong\u003e: 0.5 inches water column\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Burners\u003c\/strong\u003e: 4\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBurner Type\u003c\/strong\u003e: Non-NOx\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVent Diameter\u003c\/strong\u003e: 4 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimum Filter Size\u003c\/strong\u003e: 16 x 25 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInstallation Configuration\u003c\/strong\u003e: Upflow\/Horizontal\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Height\u003c\/strong\u003e: 33-3\/8 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Width\u003c\/strong\u003e: 21 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Depth\u003c\/strong\u003e: 28 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Weight\u003c\/strong\u003e: 118 pounds\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimum Clearance to Combustibles\u003c\/strong\u003e: 1 foot\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeat Exchanger Type\u003c\/strong\u003e: Gas\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommunication Feature\u003c\/strong\u003e: Yes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCurrent Type\u003c\/strong\u003e: AC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Type\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eETL Listed\u003c\/strong\u003e: Yes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eANSI Certified\u003c\/strong\u003e: Yes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResidential Registered Parts Warranty\u003c\/strong\u003e: All Parts - 10 Years; Heat Exchanger - 20 Years\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResidential Standard Parts Warranty\u003c\/strong\u003e: All Parts - 5 Years; Heat Exchanger - 20 Years\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResidential Registered Unit Replacement Warranty\u003c\/strong\u003e: Heat Exchanger - 10 Years\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommercial Registered Parts Warranty\u003c\/strong\u003e: All Parts - 5 Years; Heat Exchanger - 20 Years\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMulti-Family Registered Parts Warranty\u003c\/strong\u003e: All Parts - 10 Years; Heat Exchanger - 20 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: GOODMAN\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: arvt800804cn\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GOODMAN","offers":[{"title":"Default Title","offer_id":51138530902322,"sku":"ARVT800804CN","price":3392.19,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/305533726.png?v=1778258623","url":"https:\/\/voomisupply.com\/products\/goodman-arvt800804cn-80-afue-gas-furnace-80000-btu-h","provider":"Voomi Supply","version":"1.0","type":"link"}