{"product_id":"goodman-arvm970804cn-97-afue-gas-furnace-80000-btu-h","title":"Goodman arvm970804cn 97 Afue Gas Furnace 80000 Btu\/h","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\u003cp\u003eThe GOODMAN arvm970804cn is a 97 AFUE modulating gas furnace designed for upflow and horizontal installations in residential and light-commercial applications. It delivers 80,000 BTU\/h input capacity at high fire and 40,000 BTU\/h at low fire, achieving a high-fire output of 77,600 BTU\/h for efficient heat transfer. The unit runs on a variable-speed ECM blower motor rated at 1,250 RPM and 3\/4 metric horsepower, allowing the system to match airflow precisely to heating demand. A modulating gas valve enables two-stage-style efficiency and comfort control across a wide range of operating conditions. Licensed HVAC technicians handle installation and commissioning of this unit.\u003c\/p\u003e\u003cp\u003eThis furnace is built for upflow and horizontal configurations, making it suitable for installations in utility closets, basements, crawlspace platforms, and attic applications where horizontal orientation is required. The unit supports a nominal 4-ton cooling coil at 48,000 BTU\/h and is compatible with communicating system controls. With a Non-NOx burner design, it meets low-emission requirements in regions with air-quality mandates. The 115-volt, single-phase, 60 Hz power supply is standard for residential service, and the unit requires a minimum circuit ampacity of 11.4 amps with a 15-amp maximum overcurrent protection device.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e97 AFUE modulating operation with high-fire input of 80,000 BTU\/h and low-fire input of 40,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eVariable-speed ECM blower motor at 1,250 RPM for precise airflow from 905 to 1,815 cubic feet per minute\u003c\/li\u003e\n\u003cli\u003eModulating gas valve for staged combustion and improved comfort across varying load conditions\u003c\/li\u003e\n\u003cli\u003eNon-NOx burner assembly with 4 burners for compliance in low-emission installation zones\u003c\/li\u003e\n\u003cli\u003eCommunication-capable controls for integration with compatible communicating thermostats and system components\u003c\/li\u003e\n\u003cli\u003eANSI certified and ETL listed; produced in the United States\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\u003cp\u003eDesigned for upflow and horizontal residential and light-commercial gas furnace installations supporting up to 4 nominal tons of cooling capacity. Compatible with communicating system controls. Consult the equipment submittal and installation manual to confirm coil, thermostat, and venting system compatibility before installation.\u003c\/p\u003e\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\u003cp\u003eInstallation must be performed by a licensed HVAC technician in accordance with the current edition of the IFGC, NFPA 54, and all applicable local codes. Shut off gas supply and disconnect electrical power at the breaker before any service work. Venting must be sized and routed per the manufacturer installation instructions using 2-inch or 3-inch vent diameter as required; maintain a minimum 1-foot clearance to all combustible materials. Do not alter the factory wiring, gas train, or control board configuration without consulting the installation manual.\u003c\/p\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAFUE\u003c\/strong\u003e: 97\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Fire Input Capacity\u003c\/strong\u003e: 80,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Fire Output Capacity\u003c\/strong\u003e: 77,600 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-Fire Input Capacity\u003c\/strong\u003e: 40,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-Fire Output Capacity\u003c\/strong\u003e: 38,800 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Capacity (Nominal)\u003c\/strong\u003e: 48,000 BTU\/h (4 tons)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Configuration\u003c\/strong\u003e: Upflow\/Horizontal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Voltage\u003c\/strong\u003e: 115 volts AC, 1-phase, 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Circuit Ampacity\u003c\/strong\u003e: 11.4 amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Overcurrent Protection\u003c\/strong\u003e: 15 amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower Motor Type\u003c\/strong\u003e: Variable-Speed ECM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower Motor Horsepower\u003c\/strong\u003e: 3\/4 metric hp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower Motor RPM\u003c\/strong\u003e: 1,250 RPM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Flow Rate (High) - Heating\u003c\/strong\u003e: 1,815 cubic feet per minute\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Flow Rate (Low) - Heating\u003c\/strong\u003e: 905 cubic feet per minute\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Valve Type\u003c\/strong\u003e: Modulating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Burners\u003c\/strong\u003e: 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNOx Burner Type\u003c\/strong\u003e: Non-NOx\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Rise Range (High Fire)\u003c\/strong\u003e: 25-55 degrees F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Rise Range (Low Fire)\u003c\/strong\u003e: 25-55 degrees F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Static Pressure (Rated)\u003c\/strong\u003e: 0.5 inches water column\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVent Diameter\u003c\/strong\u003e: 2 inches or 3 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower Diameter\u003c\/strong\u003e: 11 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower Width\u003c\/strong\u003e: 10 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Width\u003c\/strong\u003e: 21 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Height\u003c\/strong\u003e: 34.5 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Depth\u003c\/strong\u003e: 28.875 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Weight\u003c\/strong\u003e: 140 pounds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilter Quantity\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilter Size (Minimum)\u003c\/strong\u003e: 16 x 25 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat Exchanger Type\u003c\/strong\u003e: Gas\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Clearance to Combustibles\u003c\/strong\u003e: 1 foot\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Feature\u003c\/strong\u003e: Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eANSI Certified\u003c\/strong\u003e: Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETL Listed\u003c\/strong\u003e: Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: United States\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidential Warranty (Registered) - All Parts\u003c\/strong\u003e: 10 years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidential Warranty (Registered) - Heat Exchanger\u003c\/strong\u003e: 20 years parts; 10 years unit replacement\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandard Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: GOODMAN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: arvm970804cn\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GOODMAN","offers":[{"title":"Default Title","offer_id":51138310668594,"sku":"ARVM970804CN","price":5285.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/305533720.png?v=1778253091","url":"https:\/\/voomisupply.com\/products\/goodman-arvm970804cn-97-afue-gas-furnace-80000-btu-h","provider":"Voomi Supply","version":"1.0","type":"link"}