{"product_id":"goodman-amvc960804cn-96-afue-gas-furnace-80000-btu-h","title":"Goodman amvc960804cn 96 Afue Gas Furnace 80000 Btu\/h","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe GOODMAN amvc960804cn is a 96 AFUE, two-stage, variable-speed gas furnace designed for upflow and horizontal ducted installations in residential and light-commercial applications. It delivers 80,000 BTU\/h at high-fire input with an ECM blower motor rated at up to 1,760 cubic feet per minute airflow, making it well-suited for systems requiring precise airflow management. The unit operates on 115 volts, single-phase, 60 Hz power and is ENERGY STAR certified. It is installed by licensed HVAC contractors and integrates with ComfortBridge Technology for communicating system setups.\u003c\/p\u003e\n\u003cp\u003eThis furnace is built for upflow or horizontal installation in ducted forced-air systems. It supports cooling coil configurations from 1.5 to 4 tons, covering a wide range of residential zoning requirements. The two-stage gas valve reduces short-cycling and improves comfort by modulating between low-fire (56,000 BTU\/h input) and high-fire operation. With a non-NOx burner design, it is suited for installations in regions with low-NOx combustion requirements. The unit ships from United States manufacturing and carries AHRI reference number 7368873.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e96 AFUE efficiency with two-stage combustion for reduced fuel consumption and improved comfort\u003c\/li\u003e\n  \u003cli\u003eVariable-speed ECM blower motor at up to 1,200 RPM and 1,760 cubic feet per minute high-fire airflow\u003c\/li\u003e\n  \u003cli\u003eComfortBridge Technology compatible for use in communicating system installations\u003c\/li\u003e\n  \u003cli\u003eNon-NOx burner design meets low-emissions installation requirements\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR certified and ANSI certified; ETL Listed\u003c\/li\u003e\n  \u003cli\u003eSupports 2-inch or 3-inch vent diameter for flexible venting configuration\u003c\/li\u003e\n  \u003cli\u003eSingle-filter configuration; minimum filter size 16x25\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eCompatible accessory and component references include: 0170K00000S, 0170K00001S, AFE18-60A, CTK04, CVENT-2, CVENT-3, EFR02, HASFK-2, LPLP03, LPM-08, and RF000142. Supports cooling coil tonnage from 1.5 to 4 tons in ducted upflow or horizontal configurations.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed HVAC technician in accordance with local mechanical codes and the manufacturer installation instructions. Disconnect and lock out all electrical power before servicing or installing the unit. Maintain required clearances to combustible materials as specified in the installation manual. Vent connections must be made using approved flue pipe sized for the selected 2-inch or 3-inch vent diameter and routed per local gas and mechanical code requirements.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAFUE\u003c\/strong\u003e: 96\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Fire Input Capacity\u003c\/strong\u003e: 80,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Fire Output Capacity\u003c\/strong\u003e: 76,880 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLow-Fire Input Capacity\u003c\/strong\u003e: 56,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLow-Fire Output Capacity\u003c\/strong\u003e: 53,816 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 115 volts, 1-phase, 60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMin. Circuit Amps\u003c\/strong\u003e: 10.9 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMax Overcurrent Protection\u003c\/strong\u003e: 15 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBlower Motor Type\u003c\/strong\u003e: Variable Speed ECM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBlower Motor Horsepower\u003c\/strong\u003e: 3\/4 hp\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBlower Motor RPM\u003c\/strong\u003e: 1,200 RPM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAirflow Rate High Fire\u003c\/strong\u003e: 1,760 cubic feet per minute\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAirflow Rate Low Fire\u003c\/strong\u003e: 1,245 cubic feet per minute\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBlower Diameter\u003c\/strong\u003e: 11 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBlower Width\u003c\/strong\u003e: 10 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Width\u003c\/strong\u003e: 21 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Depth\u003c\/strong\u003e: 28.75 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Height\u003c\/strong\u003e: 34.5 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Weight\u003c\/strong\u003e: 129 pounds\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVent Diameter\u003c\/strong\u003e: 2 inches or 3 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Burners\u003c\/strong\u003e: 4\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBurner Type\u003c\/strong\u003e: Non-NOx\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGas Valve Type\u003c\/strong\u003e: Two Stage Convertible\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature Rise Range (High Fire)\u003c\/strong\u003e: 25 to 55 degrees F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature Rise Range (Low Fire)\u003c\/strong\u003e: 25 to 55 degrees F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExternal Static Pressure Rated\u003c\/strong\u003e: 0.5 inches water column\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInstallation Configuration\u003c\/strong\u003e: Upflow\/Horizontal\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSupported AC Tonnage\u003c\/strong\u003e: 1.5 to 4 tons\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFilter Quantity\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimum Filter Size\u003c\/strong\u003e: 16x25\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAHRI Reference Number\u003c\/strong\u003e: 7368873\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertifications\u003c\/strong\u003e: ENERGY STAR, ANSI, ETL Listed, FER Compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty (Residential Registered)\u003c\/strong\u003e: All Parts 10 years; Heat Exchanger 20 years (unit replacement 10 years)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty (Residential Standard)\u003c\/strong\u003e: All Parts 5 years; Heat Exchanger 20 years\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: United States\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: GOODMAN\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: amvc960804cn\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GOODMAN","offers":[{"title":"Default Title","offer_id":51138494562610,"sku":"AMVC960804CN","price":4242.2,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/305533691.png?v=1778257737","url":"https:\/\/voomisupply.com\/products\/goodman-amvc960804cn-96-afue-gas-furnace-80000-btu-h","provider":"Voomi Supply","version":"1.0","type":"link"}