{"product_id":"goodman-amvc960603bn-60000-btu-h-96-afue-two-stage-gas-furnace","title":"Goodman amvc960603bn 60000 Btu\/h 96 Afue Two Stage Gas Furnace","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe GOODMAN amvc960603bn is a 96 AFUE, two-stage, variable-speed gas furnace designed for upflow and horizontal installations in ducted residential and light-commercial HVAC systems. It delivers 60,000 BTU\/h at high-fire input with a rated output of 57,660 BTU\/h, and steps down to 42,000 BTU\/h at low-fire for improved efficiency during mild heating demand. The ECM blower motor runs at variable speed up to 1,200 RPM and supports matched cooling capacity from 1.5 to 3 tons. Licensed HVAC technicians install and commission this unit. ComfortBridge Technology compatibility makes it suitable for communicating system configurations.\u003c\/p\u003e\n\u003cp\u003eThe amvc960603bn is configured for upflow or horizontal installation in ducted indoor applications. It is designed around the AMVC96 series platform and is FER compliant and ENERGY STAR certified. The unit supports nominal cooling capacity of 36,000 BTU\/h when matched with a compatible air conditioning or heat pump system. The two-stage gas valve reduces short-cycling and temperature swings, while the variable-speed ECM blower optimizes airflow across a range from 800 to 1,065 cubic feet per minute in heating mode. This furnace suits residential new construction and retrofit projects requiring high-efficiency gas heat.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e96 AFUE two-stage operation reduces fuel consumption during low-demand heating cycles\u003c\/li\u003e\n  \u003cli\u003eVariable-speed ECM blower motor with high-fire airflow of 1,065 ft3\/min and low-fire airflow of 800 ft3\/min\u003c\/li\u003e\n  \u003cli\u003eComfortBridge Technology compatible for communicating system integration\u003c\/li\u003e\n  \u003cli\u003eENERGY STAR certified and FER compliant\u003c\/li\u003e\n  \u003cli\u003eNon-NOx burner configuration with 3 burners and a gas heat exchanger\u003c\/li\u003e\n  \u003cli\u003eANSI certified and ETL listed; produced in the United States\u003c\/li\u003e\n  \u003cli\u003eSupports up to 3-ton matched cooling; compatible vent diameters of 2 inches and 3 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eThe amvc960603bn is part of the AMVC96 series and is compatible with the following referenced components and accessories per manufacturer data: 0170K00000S, 0170K00001S, AFE18-60A, CTK04, CVENT-2, CVENT-3, EFR02, HASFK-1, LPLP03, LPM-08, and RF000142. AHRI Reference Number: 7368871.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed HVAC technician in accordance with local mechanical codes, the National Fuel Gas Code (NFPA 54), and the manufacturer installation instructions. Disconnect and lock out all electrical power and shut off the gas supply before beginning any work. Vent sizing must comply with applicable codes; this unit accepts 2-inch or 3-inch vent connections. Minimum clearance to combustible materials and filter size requirements should be verified against the installation manual prior to startup.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAFUE\u003c\/strong\u003e: 96\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Fire Input Capacity\u003c\/strong\u003e: 60,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Fire Output Capacity\u003c\/strong\u003e: 57,660 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLow-Fire Input Capacity\u003c\/strong\u003e: 42,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLow-Fire Output Capacity\u003c\/strong\u003e: 40,362 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNominal Cooling Capacity\u003c\/strong\u003e: 36,000 BTU\/h (3 tons)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Voltage\u003c\/strong\u003e: 115 volts AC, 1 phase, 60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMax Overcurrent Protection\u003c\/strong\u003e: 15 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMin Circuit Amps\u003c\/strong\u003e: 7.6 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBlower Motor Type\u003c\/strong\u003e: Variable Speed ECM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBlower Motor Horsepower\u003c\/strong\u003e: 1\/2 hp\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBlower Motor RPM\u003c\/strong\u003e: 1,200 RPM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAir Flow Rate High Fire (Heating)\u003c\/strong\u003e: 1,065 ft3\/min\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAir Flow Rate Low Fire (Heating)\u003c\/strong\u003e: 800 ft3\/min\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBlower Diameter\u003c\/strong\u003e: 11 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBlower Width\u003c\/strong\u003e: 8 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Width\u003c\/strong\u003e: 17.5 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Height\u003c\/strong\u003e: 34.5 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Depth\u003c\/strong\u003e: 28.75 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 108 pounds\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGas Valve Type\u003c\/strong\u003e: Two Stage\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNumber of Burners\u003c\/strong\u003e: 3\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBurner Type\u003c\/strong\u003e: Non-NOx\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeat Exchanger Type\u003c\/strong\u003e: Gas\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVent Diameter\u003c\/strong\u003e: 2 inches; 3 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature Rise Range (High Fire)\u003c\/strong\u003e: 35-65 degrees F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature Rise Range (Low Fire)\u003c\/strong\u003e: 35-65 degrees F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExternal Static Pressure Rated\u003c\/strong\u003e: 0.5 inches W.C.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFilter Quantity\u003c\/strong\u003e: 1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFilter Size Minimum\u003c\/strong\u003e: 16x25\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInstallation Configuration\u003c\/strong\u003e: Upflow\/Horizontal\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAHRI Reference Number\u003c\/strong\u003e: 7368871\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertifications\u003c\/strong\u003e: ENERGY STAR, ANSI, ETL Listed, FER Compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: United States\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRegistered Residential Parts Warranty\u003c\/strong\u003e: All Parts - 10 Years; Heat Exchanger - 20 Years (upon registration)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard Residential Parts Warranty\u003c\/strong\u003e: All Parts - 5 Years; Heat Exchanger - 20 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: GOODMAN\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: amvc960603bn\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GOODMAN","offers":[{"title":"Default Title","offer_id":51138890137906,"sku":"AMVC960603BN","price":3540.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/305534343.png?v=1778265408","url":"https:\/\/voomisupply.com\/products\/goodman-amvc960603bn-60000-btu-h-96-afue-two-stage-gas-furnace","provider":"Voomi Supply","version":"1.0","type":"link"}