{"product_id":"goodman-amvc960403bn-40k-btu-96-afue-two-stage-gas-furnace","title":"Goodman amvc960403bn 40K Btu 96 Afue Two Stage Gas Furnace","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\u003cp\u003eThe Goodman amvc960403bn is a 96 AFUE two-stage, variable-speed upflow\/horizontal gas furnace rated at 40,000 BTU\/h high-fire input with 38,440 BTU\/h output. It uses an ECM blower motor running at up to 1,200 RPM for variable-speed airflow, delivering between 710 and 1,015 cubic feet per minute in heating mode. The two-stage gas valve allows low-fire operation at 28,000 BTU\/h input, reducing short-cycling and improving comfort. This unit is ENERGY STAR certified, ANSI certified, ETL listed, and FER compliant. Licensed HVAC technicians install this furnace as part of a ducted forced-air system in residential or light commercial applications.\u003c\/p\u003e\u003cp\u003eThe amvc960403bn is configured for upflow or horizontal installation and is sized for nominal 3-ton cooling capacity, with blower compatibility ranging from 1.5 to 3 tons. The cabinet measures 17.5 inches wide, 34.5 inches tall, and 28.75 inches deep, making it suitable for closet, utility room, basement, or attic horizontal installations. It supports ComfortBridge Technology communication for use in communicating system setups. The Non-NOx burner design meets low-emissions requirements in applicable jurisdictions. A single 16x25 filter services the unit.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e96 AFUE two-stage operation: high fire at 40,000 BTU\/h input, low fire at 28,000 BTU\/h input\u003c\/li\u003e\n\u003cli\u003eVariable-speed ECM blower motor at up to 1,200 RPM for quiet, efficient airflow\u003c\/li\u003e\n\u003cli\u003eComfortBridge Technology compatible for communicating system control\u003c\/li\u003e\n\u003cli\u003eUpflow and horizontal installation configurations supported in a single unit\u003c\/li\u003e\n\u003cli\u003eNon-NOx burner design for low-emissions compliance\u003c\/li\u003e\n\u003cli\u003eENERGY STAR certified, ANSI certified, ETL listed, and FER compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\u003cp\u003eThe amvc960403bn is part of the Goodman AMVC96 series and is compatible with 1.5 to 3-ton cooling systems. Referenced accessory and component part numbers from the manufacturer include 0170K00000S, 0170K00001S, AFE18-60A, CTK04, CVENT-2, CVENT-3, EFR02, HASFK-1, LPLP03, LPM-08, and RF000142. AHRI Reference Number: 7368870.\u003c\/p\u003e\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\u003cp\u003eInstallation must be performed by a licensed HVAC technician in accordance with applicable local codes, the National Fuel Gas Code (NFPA 54\/ANSI Z223.1), and the manufacturer installation instructions. Disconnect all power to the system before beginning any service or installation work. Vent diameter is 2 inches or 3 inches; verify vent sizing and material against local code and the installation manual before connecting. Minimum clearance to combustible materials must be maintained per rated specifications.\u003c\/p\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAFUE\u003c\/strong\u003e: 96\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Fire Input Capacity\u003c\/strong\u003e: 40,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Fire Output Capacity\u003c\/strong\u003e: 38,440 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-Fire Input Capacity\u003c\/strong\u003e: 28,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-Fire Output Capacity\u003c\/strong\u003e: 26,908 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Cooling Capacity\u003c\/strong\u003e: 36,000 BTU\/h (3 tons)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower AC Tonnage Range\u003c\/strong\u003e: 1.5 to 3 tons\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Flow Rate High (Heating)\u003c\/strong\u003e: 1,015 ft3\/min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Flow Rate Low (Heating)\u003c\/strong\u003e: 710 ft3\/min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Speed Type\u003c\/strong\u003e: Variable Speed ECM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower Motor Horsepower\u003c\/strong\u003e: 1\/2 hp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower Motor RPM\u003c\/strong\u003e: 1,200 RPM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower Diameter\u003c\/strong\u003e: 10 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower Width\u003c\/strong\u003e: 8 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Voltage\u003c\/strong\u003e: 115 volts, 1-phase, 60 Hz, AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMin. Circuit Amps\u003c\/strong\u003e: 7.6 amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Overcurrent Protection\u003c\/strong\u003e: 15 amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Rise Range (High Fire)\u003c\/strong\u003e: 20-50 degrees F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Rise Range (Low Fire)\u003c\/strong\u003e: 20-50 degrees F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Static Pressure (Rated)\u003c\/strong\u003e: 0.5 inches W.C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Valve Type\u003c\/strong\u003e: Two-Stage Convertible\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Burners\u003c\/strong\u003e: 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBurner Type\u003c\/strong\u003e: Non-NOx\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat Exchanger Type\u003c\/strong\u003e: Gas\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVent Diameter\u003c\/strong\u003e: 2 inches or 3 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Configuration\u003c\/strong\u003e: Upflow\/Horizontal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Width\u003c\/strong\u003e: 17.5 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Height\u003c\/strong\u003e: 34.5 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Depth\u003c\/strong\u003e: 28.75 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Weight\u003c\/strong\u003e: 119 pounds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilter Quantity\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilter Size (Min)\u003c\/strong\u003e: 16x25 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Feature\u003c\/strong\u003e: ComfortBridge Technology compatible\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI Reference Number\u003c\/strong\u003e: 7368870\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: AMVC96\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: United States\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications\u003c\/strong\u003e: ENERGY STAR, ANSI, ETL Listed, FER Compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty (Residential Registered)\u003c\/strong\u003e: Heat Exchanger 20 Years Parts; All Parts 10 Years Parts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty (Standard)\u003c\/strong\u003e: All Parts 5 Years Parts; Heat Exchanger 20 Years Parts\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandard Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Goodman\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: amvc960403bn\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GOODMAN","offers":[{"title":"Default Title","offer_id":51138625241394,"sku":"AMVC960403BN","price":3409.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/305534337.png?v=1778260495","url":"https:\/\/voomisupply.com\/products\/goodman-amvc960403bn-40k-btu-96-afue-two-stage-gas-furnace","provider":"Voomi Supply","version":"1.0","type":"link"}