{"product_id":"goodman-am9c961004cn-gas-furnace-96-afue-100000-btu-h","title":"Goodman am9c961004cn Gas Furnace 96 Afue 100000 Btu\/h","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe GOODMAN am9c961004cn is a 96 AFUE, two-stage, upflow\/horizontal gas furnace with a multi-speed ECM blower motor. It delivers 100,000 BTU\/h input capacity at high fire and 96,000 BTU\/h output, achieving 96 percent thermal efficiency. The two-stage gas valve allows the unit to operate at a reduced 70,000 BTU\/h input on low fire, improving comfort and efficiency during moderate heating loads. The ECM blower motor adjusts airflow to match demand, reducing electrical consumption compared to a standard PSC motor. Licensed HVAC technicians install and commission this unit as part of a ducted forced-air heating system in residential or light commercial applications.\u003c\/p\u003e\n\u003cp\u003eThis furnace is configured for upflow or horizontal installation, making it suitable for basement, closet, utility room, and attic installations where ductwork connects above or to the side of the unit. The unit width of 21 inches fits standard air handler closets and platform installations. With a nominal cooling capacity pairing of 48,000 BTU\/h, it is sized to match a 4-ton cooling system. The low NOx burner design meets low-emission requirements in applicable jurisdictions. Single-phase, 115-volt power supply at 60 Hz is required, with a minimum circuit ampacity of 14.4 amps and maximum overcurrent protection of 25 amps.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e96 AFUE two-stage operation with high-fire input of 100,000 BTU\/h and low-fire input of 70,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003eMulti-speed ECM blower motor reduces electrical demand and improves airflow control across heating and cooling modes\u003c\/li\u003e\n  \u003cli\u003eUpflow\/horizontal installation configuration supports multiple mounting orientations\u003c\/li\u003e\n  \u003cli\u003eLow NOx burner design for compliance in low-emission regions\u003c\/li\u003e\n  \u003cli\u003eAir-cooled heat exchanger with temperature rise range of 35 to 65 degrees F at both high and low fire\u003c\/li\u003e\n  \u003cli\u003eProduced in the United States\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned for ducted upflow or horizontal forced-air heating systems sized for 4-ton nominal cooling capacity. Compatible accessory and component part references from the manufacturer include: 0170K00000S, 0170K00001S, 0270F05404, 72950, 72951, AFE18-60A, EFR02, HASFK-2, LPLP03, LPM-08, LPM-08, and RF000142.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by a licensed HVAC technician in accordance with local mechanical codes, the National Fuel Gas Code (NFPA 54\/ANSI Z223.1), and the manufacturer installation instructions. Shut off gas supply and disconnect electrical power before servicing or connecting the unit. Verify that flue venting, gas line sizing, and electrical supply meet the specifications listed on the unit nameplate and in the installation manual. Do not exceed the maximum overcurrent protection rating of 25 amps when sizing the branch circuit.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAFUE\u003c\/strong\u003e: 96%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Fire Input Capacity\u003c\/strong\u003e: 100,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Fire Output Capacity\u003c\/strong\u003e: 96,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLow-Fire Input Capacity\u003c\/strong\u003e: 70,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLow-Fire Output Capacity\u003c\/strong\u003e: 67,200 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNominal Cooling Capacity\u003c\/strong\u003e: 48,000 BTU\/h (4 ton)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGas Valve Type\u003c\/strong\u003e: Two Stage\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMotor Speed Type\u003c\/strong\u003e: Multi Speed ECM\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBlower Motor Horsepower\u003c\/strong\u003e: 1 metric hp\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAirflow Rate High Fire Heating\u003c\/strong\u003e: 1,699 ft3\/min\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAirflow Rate Low Fire Heating\u003c\/strong\u003e: 1,369 ft3\/min\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature Rise Range\u003c\/strong\u003e: 35 to 65 degrees F (high and low fire)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Voltage\u003c\/strong\u003e: 115 volts, 1-phase, 60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMinimum Circuit Ampacity\u003c\/strong\u003e: 14.4 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaximum Overcurrent Protection\u003c\/strong\u003e: 25 amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInstallation Configuration\u003c\/strong\u003e: Upflow\/Horizontal\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Width\u003c\/strong\u003e: 21 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Height\u003c\/strong\u003e: 33-3\/8 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Depth\u003c\/strong\u003e: 28 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBlower Diameter\u003c\/strong\u003e: 11 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBlower Width\u003c\/strong\u003e: 10 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeat Exchanger Type\u003c\/strong\u003e: Air Cooled\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNOx Burner Type\u003c\/strong\u003e: Low NOx\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Type\u003c\/strong\u003e: Indoor Ducted\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 140 pounds\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: United States\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard Residential Parts Warranty\u003c\/strong\u003e: All Parts 5 Years; Heat Exchanger 20 Years\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRegistered Residential Parts Warranty\u003c\/strong\u003e: All Parts 10 Years; Heat Exchanger 20 Years; Heat Exchanger 79 Years\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRegistered Residential Unit Replacement Warranty\u003c\/strong\u003e: Heat Exchanger 10 Years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: GOODMAN\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: am9c961004cn\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GOODMAN","offers":[{"title":"Default Title","offer_id":51138317877554,"sku":"AM9C961004CN","price":3512.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/305534336.png?v=1778253256","url":"https:\/\/voomisupply.com\/products\/goodman-am9c961004cn-gas-furnace-96-afue-100000-btu-h","provider":"Voomi Supply","version":"1.0","type":"link"}