{"product_id":"goodman-alxs3nn6010-5-ton-13-4-seer2-r-32-outdoor-condensing-unit","title":"Goodman alxs3nn6010 5 Ton 13.4 SEER2 R-32 Outdoor Condensing Unit","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe Goodman alxs3nn6010 is a 5-ton, single-stage outdoor condensing unit rated at 60,000 BTU\/h nominal cooling capacity and 13.4 SEER2 efficiency. It operates on R-32 refrigerant and is designed for cooling-only applications in North region installations per DOE regional compliance guidelines. The scroll compressor runs on a single-speed motor with a top-discharge configuration, drawing 23.9 amps at 208\/230 volts, 60 Hz, single phase. This unit is manufactured in the United States and targets residential and light commercial new-construction or replacement installs performed by licensed HVAC technicians.\u003c\/p\u003e\n\u003cp\u003eThe alxs3nn6010 is intended for split-system cooling-only configurations in North region climates. It operates within a cooling range of 55 degrees F to 115 degrees F ambient, making it suitable for a wide range of seasonal conditions. The unit ships pre-charged with 91 oz of R-32 refrigerant and supports a standard line set up to 200 ft in length with up to 79 ft of vertical rise. It is non-communicating, connecting to conventional single-stage air handlers or fan coils without a proprietary control bus.\u003c\/p\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e60,000 BTU\/h nominal cooling capacity (55,000 BTU\/h rated) with 13.4 SEER2 and EER2 of 11\u003c\/li\u003e\n  \u003cli\u003eR-32 refrigerant with factory charge of 91 oz and 0.58 lb additional charge per foot of line set beyond pre-charged length\u003c\/li\u003e\n  \u003cli\u003eSingle-stage scroll compressor with top-discharge fan configuration\u003c\/li\u003e\n  \u003cli\u003eNon-communicating controls compatible with standard single-stage thermostat wiring\u003c\/li\u003e\n  \u003cli\u003eOperating sound level of 74 dBA at high cooling\u003c\/li\u003e\n  \u003cli\u003eProduced in the United States; DOE North region compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatibility\u003c\/h4\u003e\n\u003cp\u003eDesigned as a cooling-only outdoor condensing unit for split-system HVAC configurations meeting DOE North region requirements. Compatible accessory and component references from the manufacturer include: 0130R00000S, ABK-20, ASC01A, CSR-U-1, FSK01A, and LSK02A. Verify indoor unit compatibility and R-32 refrigerant handling certification before installation.\u003c\/p\u003e\n\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\n\u003cp\u003eInstallation must be performed by an EPA 608-certified HVAC technician with appropriate R-32 handling qualifications, as R-32 is an A2L mildly flammable refrigerant subject to specific handling and ventilation requirements. Disconnect and lock out all electrical power before connecting refrigerant lines or making any electrical terminations; minimum circuit ampacity is 31.1 A with a maximum overcurrent protection of 50 A. Follow local mechanical and electrical codes, including NEC requirements for disconnect placement and wire sizing. Pre-charged line length is 15 ft; apply the rated additional charge per foot for any line set length beyond that value.\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCooling Capacity (Nominal)\u003c\/strong\u003e: 60,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCooling Capacity (Rated)\u003c\/strong\u003e: 55,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTonnage\u003c\/strong\u003e: 5 tons\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSEER2\u003c\/strong\u003e: 13.4\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEER2\u003c\/strong\u003e: 11\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompressor Type\u003c\/strong\u003e: Scroll, Single Stage\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRefrigerant Type\u003c\/strong\u003e: R-32\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFactory Refrigerant Charge\u003c\/strong\u003e: 91 oz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdditional Refrigerant Charge\u003c\/strong\u003e: 0.58 lb per ft\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePre-Charged Line Length\u003c\/strong\u003e: 15 ft\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMax Line Set Length\u003c\/strong\u003e: 200 ft\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMax Vertical Rise\u003c\/strong\u003e: 79 ft\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Voltage\u003c\/strong\u003e: 208\/230 volts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Phase\u003c\/strong\u003e: 1 Ph\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Frequency\u003c\/strong\u003e: 60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMin. Circuit Amps\u003c\/strong\u003e: 31.1 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMax Overcurrent Protection\u003c\/strong\u003e: 50 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFan\/Compressor Drive Input\u003c\/strong\u003e: 23.9 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRated Load Amps\u003c\/strong\u003e: 23.872 A\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSound Pressure (High Cooling)\u003c\/strong\u003e: 74 dBA\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Height\u003c\/strong\u003e: 39.5 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Width\u003c\/strong\u003e: 35.5 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Depth\u003c\/strong\u003e: 35.5 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 229 pounds\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLiquid Pipe Size\u003c\/strong\u003e: 3\/8 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGas Pipe Size\u003c\/strong\u003e: 1-1\/8 inches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDischarge Configuration\u003c\/strong\u003e: Top Discharge\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCooling Operation Range (Min)\u003c\/strong\u003e: 55 degrees F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCooling Operation Range (Max)\u003c\/strong\u003e: 115 degrees F\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommunication Type\u003c\/strong\u003e: Non-Communicating\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDOE Regional Compliance\u003c\/strong\u003e: North\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRegistered Residential Parts Warranty\u003c\/strong\u003e: 10 Years\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRegistered Commercial Parts Warranty\u003c\/strong\u003e: 5 Years\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard Residential Parts Warranty\u003c\/strong\u003e: 5 Years\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: United States\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eStandard Information\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Goodman\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: alxs3nn6010\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GOODMAN","offers":[{"title":"Default Title","offer_id":51138377154866,"sku":"ALXS3NN6010","price":4354.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/305534351.png?v=1778254686","url":"https:\/\/voomisupply.com\/products\/goodman-alxs3nn6010-5-ton-13-4-seer2-r-32-outdoor-condensing-unit","provider":"Voomi Supply","version":"1.0","type":"link"}