{"product_id":"goodman-alxs3nn1810-1-5-ton-13-4-seer2-r-32-ac-outdoor-unit","title":"Goodman alxs3nn1810 1.5 Ton 13.4 SEER2 R-32 Ac Outdoor Unit","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\u003cp\u003eThe GOODMAN alxs3nn1810 is a 1.5-ton, single-stage outdoor condensing unit designed for cooling-only split air conditioning systems. Rated at 18,000 BTU\/h with a 13.4 SEER2 efficiency rating and an EER2 of 11.2, this unit uses R-32 refrigerant and operates on a 208\/230-volt, single-phase, 60 Hz power supply. It features a rotary compressor with top-discharge airflow and a single-speed fan motor. Licensed HVAC technicians install this unit as the outdoor half of a split cooling system in residential and light commercial applications in the DOE North compliance region. The unit is manufactured in the United States.\u003c\/p\u003e\u003cp\u003eThis condensing unit is intended for split-system cooling installations in the DOE North regional compliance zone. It is suited for residential and multi-family applications requiring a compact, non-communicating outdoor unit. The unit operates within a standard cooling ambient range of 55 degrees F to 115 degrees F and ships factory pre-charged with R-32 refrigerant for a 15-foot line set. Maximum line set length is 150 feet, with a maximum vertical run of 79 feet. Typical installations pair this unit with a compatible indoor air handler or coil assembly.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e18,000 BTU\/h rated cooling capacity at 1.5 tons\u003c\/li\u003e\n\u003cli\u003e13.4 SEER2 and 11.2 EER2 efficiency ratings for DOE North compliance\u003c\/li\u003e\n\u003cli\u003eR-32 refrigerant with factory charge of 53 oz for a 15-foot pre-charged line set\u003c\/li\u003e\n\u003cli\u003eSingle-stage rotary compressor with top-discharge configuration\u003c\/li\u003e\n\u003cli\u003eNon-communicating design for straightforward thermostat and air handler compatibility\u003c\/li\u003e\n\u003cli\u003eSound pressure level of 74 dBA during cooling operation\u003c\/li\u003e\n\u003cli\u003eManufactured in the United States\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\u003cp\u003eDesigned as an OEM-style outdoor condensing unit within the ALXS3N series for non-communicating split cooling systems in the DOE North region. Refer to the manufacturer system combination guide to confirm matched indoor coil or air handler compatibility before installation.\u003c\/p\u003e\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\u003cp\u003eInstallation must be performed by a licensed HVAC technician in accordance with local mechanical codes and EPA Section 608 refrigerant handling regulations. Disconnect and lock out all power to the system before connecting or servicing refrigerant lines, electrical connections, or the unit itself. Minimum circuit ampacity is 10.9 amps with a maximum overcurrent protection of 15 amps; verify that the service disconnect and wiring are sized accordingly. Liquid line connection is 3\/8 inch O.D. and suction line connection is 3\/4 inch O.D.; use proper flaring or brazing procedures and pressure-test the line set before charging.\u003c\/p\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Capacity (Rated)\u003c\/strong\u003e: 18,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTonnage\u003c\/strong\u003e: 1.5 tons\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSEER2\u003c\/strong\u003e: 13.4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEER2\u003c\/strong\u003e: 11.2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor Stages\u003c\/strong\u003e: Single Stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor Type\u003c\/strong\u003e: Rotary\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Voltage\u003c\/strong\u003e: 208\/230 volts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Phase\u003c\/strong\u003e: Single Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Frequency\u003c\/strong\u003e: 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Load Amps\u003c\/strong\u003e: 8.2 amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMin. Circuit Amps\u003c\/strong\u003e: 10.9 amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Overcurrent Protection\u003c\/strong\u003e: 15 amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant Type\u003c\/strong\u003e: R-32\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory Refrigerant Charge\u003c\/strong\u003e: 53 oz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdditional Refrigerant Charge\u003c\/strong\u003e: 0.55 lb per foot\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Charged Line Length\u003c\/strong\u003e: 15 feet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Line Set Length\u003c\/strong\u003e: 150 feet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Vertical Line Set\u003c\/strong\u003e: 79 feet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiquid Line Pipe Size\u003c\/strong\u003e: 3\/8 inch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Line Pipe Size\u003c\/strong\u003e: 3\/4 inch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiquid Valve Size (O.D.)\u003c\/strong\u003e: 3\/8 inch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuction Valve Size (O.D.)\u003c\/strong\u003e: 3\/4 inch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Operation Range (Min)\u003c\/strong\u003e: 55 degrees F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Operation Range (Max)\u003c\/strong\u003e: 115 degrees F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSound Pressure Level (Cooling)\u003c\/strong\u003e: 74 dBA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Height\u003c\/strong\u003e: 27.5 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Width\u003c\/strong\u003e: 26 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Depth\u003c\/strong\u003e: 26 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Weight\u003c\/strong\u003e: 114 pounds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Configuration\u003c\/strong\u003e: Top Discharge\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Speed Type\u003c\/strong\u003e: Single Speed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Feature\u003c\/strong\u003e: Non-Communicating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDOE Regional Compliance\u003c\/strong\u003e: North\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: United States\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidential Registered Parts Warranty\u003c\/strong\u003e: 10 years all parts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidential Standard Parts Warranty\u003c\/strong\u003e: 5 years all parts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial Parts Warranty\u003c\/strong\u003e: 5 years all parts\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandard Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: GOODMAN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: alxs3nn1810\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GOODMAN","offers":[{"title":"Default Title","offer_id":51138223046962,"sku":"ALXS3NN1810","price":2461.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/305526244.jpg?v=1778250814","url":"https:\/\/voomisupply.com\/products\/goodman-alxs3nn1810-1-5-ton-13-4-seer2-r-32-ac-outdoor-unit","provider":"Voomi Supply","version":"1.0","type":"link"}