{"product_id":"goodman-advt961005cn-100000-btu-h-96-afue-gas-furnace","title":"Goodman advt961005cn 100000 Btu\/h 96 Afue Gas Furnace","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\u003cp\u003eThe GOODMAN advt961005cn is a 96 AFUE two-stage, variable-speed ECM gas furnace designed for downflow and horizontal installations. Rated at 100,000 BTU\/h high-fire input with 96,100 BTU\/h output, this unit delivers efficient, staged heat across residential and light-commercial applications. The variable-speed ECM blower motor runs at up to 1,250 RPM with a high-fire airflow of 1,775 cubic feet per minute, modulating output to match heating demand. A licensed HVAC technician handles installation, and the unit ships from United States manufacturing. The two-stage gas valve allows a low-fire input of 70,000 BTU\/h, reducing short cycling and improving humidity management in shoulder seasons.\u003c\/p\u003e\u003cp\u003eThis furnace is intended for downflow and horizontal installations in indoor residential and multi-family settings. The Non-NOx burner configuration makes it suitable for regions with low-emissions requirements. With a nominal cooling coil match of 60,000 BTU\/h and 5-ton tonnage rating, it pairs with compatible split-system cooling equipment. The unit requires a 115-volt, single-phase, 60 Hz power supply with a minimum circuit ampacity of 13.8 amps and maximum overcurrent protection of 20 amps. Temperature rise range at both high and low fire is 35 to 65 degrees F.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e96 AFUE two-stage combustion with 100,000 BTU\/h high-fire and 70,000 BTU\/h low-fire input\u003c\/li\u003e\n\u003cli\u003eVariable-speed ECM blower motor rated at 1,250 RPM for quiet, efficient airflow modulation\u003c\/li\u003e\n\u003cli\u003eDownflow and horizontal installation configuration for flexible placement\u003c\/li\u003e\n\u003cli\u003eNon-NOx burner design meets low-emissions standards in restricted air districts\u003c\/li\u003e\n\u003cli\u003eCommunication-capable controls support compatible thermostat and zoning systems\u003c\/li\u003e\n\u003cli\u003eANSI certified and ETL listed; produced in the United States\u003c\/li\u003e\n\u003cli\u003e5-burner heat exchanger with 2-inch or 3-inch venting options\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\u003cp\u003eDesigned for downflow and horizontal installation as an indoor gas furnace. Nominal cooling match is rated at 60,000 BTU\/h (5 tons). Vent connections accept 2-inch or 3-inch diameter flue pipe. No specific compatible model numbers or replacement part numbers were provided in the product data.\u003c\/p\u003e\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\u003cp\u003eInstallation must be performed by a licensed HVAC technician in accordance with local codes, the National Fuel Gas Code (NFPA 54), and the manufacturer installation instructions. Shut off the gas supply and disconnect electrical power before any service or connection work. Maintain a minimum clearance of 0.5 feet to combustible materials as specified. Do not reduce vent diameter below the minimum listed for the flue configuration selected.\u003c\/p\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAFUE\u003c\/strong\u003e: 96%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Fire Input Capacity\u003c\/strong\u003e: 100,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Fire Output Capacity\u003c\/strong\u003e: 96,100 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-Fire Input Capacity\u003c\/strong\u003e: 70,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-Fire Output Capacity\u003c\/strong\u003e: 67,270 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Capacity (Nominal)\u003c\/strong\u003e: 60,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTonnage\u003c\/strong\u003e: 5 tons\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Valve Type\u003c\/strong\u003e: Two Stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Speed Type\u003c\/strong\u003e: Variable Speed ECM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower Motor RPM\u003c\/strong\u003e: 1,250 RPM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower Motor Horsepower\u003c\/strong\u003e: 1 metric hp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower Diameter\u003c\/strong\u003e: 11 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower Width\u003c\/strong\u003e: 10 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAirflow Rate High Fire\u003c\/strong\u003e: 1,775 ft3\/min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAirflow Rate Low Fire\u003c\/strong\u003e: 1,240 ft3\/min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Rise Range\u003c\/strong\u003e: 35-65 degrees F (high and low fire)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Voltage\u003c\/strong\u003e: 115 volts AC, 1-phase, 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Circuit Amps\u003c\/strong\u003e: 13.8 amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Overcurrent Protection\u003c\/strong\u003e: 20 amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Configuration\u003c\/strong\u003e: Downflow\/Horizontal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Type\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBurner Type\u003c\/strong\u003e: Non-NOx\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Burners\u003c\/strong\u003e: 5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVent Diameter\u003c\/strong\u003e: 2 inches or 3 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Static Pressure (Rated)\u003c\/strong\u003e: 0.5 in wg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilter Quantity\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilter Size (Min)\u003c\/strong\u003e: 20x25\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Height\u003c\/strong\u003e: 34.5 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Width\u003c\/strong\u003e: 21 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Depth\u003c\/strong\u003e: 28.875 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Weight\u003c\/strong\u003e: 145 pounds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Clearance to Combustibles\u003c\/strong\u003e: 0.5 feet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Feature\u003c\/strong\u003e: Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eANSI Certified\u003c\/strong\u003e: Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eETL Listed\u003c\/strong\u003e: Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: United States\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegistered Residential Parts Warranty\u003c\/strong\u003e: All Parts 10 Years; Heat Exchanger 20 Years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Residential Parts Warranty\u003c\/strong\u003e: All Parts 5 Years; Heat Exchanger 20 Years\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandard Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: GOODMAN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: advt961005cn\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GOODMAN","offers":[{"title":"Default Title","offer_id":51138818900274,"sku":"ADVT961005CN","price":5655.23,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/305526190.jpg?v=1778264013","url":"https:\/\/voomisupply.com\/products\/goodman-advt961005cn-100000-btu-h-96-afue-gas-furnace","provider":"Voomi Supply","version":"1.0","type":"link"}