{"product_id":"goodman-advt960804cn-96-afue-gas-furnace-80000-btu-h","title":"Goodman advt960804cn 96 Afue Gas Furnace 80000 Btu\/h","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\u003cp\u003eThe GOODMAN advt960804cn is a 96 AFUE, two-stage, variable-speed ECM gas furnace designed for downflow and horizontal installations. Rated at 80,000 BTU\/h high-fire input with a corresponding output of 76,880 BTU\/h, it delivers efficient heat while minimizing fuel waste. The ECM blower motor operates at variable speeds up to 1,250 RPM, allowing precise airflow control across both heating stages. Licensed HVAC technicians install this unit in residential and light-commercial applications where energy efficiency and quiet, modulating operation are required. The Non-NOx burner configuration meets low-emissions requirements in applicable jurisdictions.\u003c\/p\u003e\u003cp\u003eThis furnace is configured for downflow and horizontal installations, making it suitable for closet, alcove, or crawlspace applications where upflow units will not fit. With a nominal cooling capacity pairing of 48,000 BTU\/h (4 tons) and a high-fire airflow of 1,760 cubic feet per minute, it is sized for larger residential systems or small commercial spaces. The two-stage gas valve reduces short cycling and improves comfort at low-fire capacity of 56,000 BTU\/h input. Communication-capable controls allow integration with compatible thermostats and zoning systems.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e96 AFUE two-stage operation: 80,000 BTU\/h high fire, 56,000 BTU\/h low fire\u003c\/li\u003e\n\u003cli\u003eVariable-speed ECM blower motor rated at 1,250 RPM with 3\/4 hp output\u003c\/li\u003e\n\u003cli\u003eDownflow and horizontal installation configurations supported\u003c\/li\u003e\n\u003cli\u003eNon-NOx burner design with 4 burners for low-emissions compliance\u003c\/li\u003e\n\u003cli\u003eCommunication-capable controls for compatible thermostat integration\u003c\/li\u003e\n\u003cli\u003eETL Listed and ANSI Certified for verified safety compliance\u003c\/li\u003e\n\u003cli\u003eHeat exchanger warranted up to 20 years on registered residential units\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\u003cp\u003eDesigned as an OEM downflow and horizontal gas furnace for residential and light-commercial forced-air heating systems with a 4-ton nominal cooling match and 115-volt, single-phase, 60 Hz electrical service.\u003c\/p\u003e\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\u003cp\u003eInstallation must be performed by a licensed HVAC technician in accordance with the International Fuel Gas Code (IFGC), local mechanical codes, and the manufacturer installation instructions. Shut off gas supply and disconnect electrical power before servicing or connecting the unit. Vent diameter connections of 2 inches or 3 inches must be confirmed against the specific vent run length and configuration per the installation manual. Minimum clearances to combustible materials must be maintained as specified; this unit requires a dedicated 15-amp overcurrent protection circuit with a minimum circuit ampacity of 10.8 amps.\u003c\/p\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAFUE\u003c\/strong\u003e: 96\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Fire Input Capacity\u003c\/strong\u003e: 80,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Fire Output Capacity\u003c\/strong\u003e: 76,880 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-Fire Input Capacity\u003c\/strong\u003e: 56,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-Fire Output Capacity\u003c\/strong\u003e: 53,816 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Cooling Capacity\u003c\/strong\u003e: 48,000 BTU\/h (4 tons)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Valve Type\u003c\/strong\u003e: Two Stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Speed Type\u003c\/strong\u003e: Variable Speed (ECM)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower Motor Horsepower\u003c\/strong\u003e: 3\/4 hp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower Motor RPM\u003c\/strong\u003e: 1,250 RPM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower Diameter\u003c\/strong\u003e: 11 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower Width\u003c\/strong\u003e: 10 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Flow Rate High Heating\u003c\/strong\u003e: 1,760 ft³\/min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Flow Rate Low Heating\u003c\/strong\u003e: 1,240 ft³\/min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Rise Range High Fire\u003c\/strong\u003e: 35-65 degrees F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Rise Range Low Fire\u003c\/strong\u003e: 35-65 degrees F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Voltage\u003c\/strong\u003e: 115 volts AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Phase\u003c\/strong\u003e: 1 Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Frequency\u003c\/strong\u003e: 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Overcurrent Protection\u003c\/strong\u003e: 15 amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMin Circuit Amps\u003c\/strong\u003e: 10.8 amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVent Diameter\u003c\/strong\u003e: 2 inches or 3 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Static Pressure Rated\u003c\/strong\u003e: 0.5 in w.c.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Burners\u003c\/strong\u003e: 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBurner Type\u003c\/strong\u003e: Non-NOx\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Configuration\u003c\/strong\u003e: Downflow\/Horizontal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Height\u003c\/strong\u003e: 34.5 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Width\u003c\/strong\u003e: 21 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Depth\u003c\/strong\u003e: 28.875 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Weight\u003c\/strong\u003e: 132 pounds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilter Quantity\u003c\/strong\u003e: 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilter Size Minimum\u003c\/strong\u003e: 16x25\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat Exchanger Type\u003c\/strong\u003e: Gas\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Feature\u003c\/strong\u003e: Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Type\u003c\/strong\u003e: Indoor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications\u003c\/strong\u003e: ETL Listed, ANSI Certified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: United States\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegistered Residential Parts Warranty\u003c\/strong\u003e: All Parts 10 Years; Heat Exchanger 20 Years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Residential Parts Warranty\u003c\/strong\u003e: All Parts 5 Years; Heat Exchanger 20 Years\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandard Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: GOODMAN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: advt960804cn\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GOODMAN","offers":[{"title":"Default Title","offer_id":51138216591666,"sku":"ADVT960804CN","price":5263.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/305533705.png?v=1782250409","url":"https:\/\/voomisupply.com\/products\/goodman-advt960804cn-96-afue-gas-furnace-80000-btu-h","provider":"Voomi Supply","version":"1.0","type":"link"}