{"product_id":"goodman-ad9s960804cn-96-afue-gas-furnace-80000-btu-h","title":"Goodman ad9s960804cn 96 Afue Gas Furnace 80000 Btu\/h","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\u003cp\u003eThe GOODMAN ad9s960804cn is a 96 AFUE single-stage, multi-speed ECM gas furnace configured for downflow and horizontal installation. Rated at 80,000 BTU\/h high-fire input with a high-fire output of 76,880 BTU\/h, it delivers 96 percent thermal efficiency in a ducted indoor application. The unit operates on 115 volts, 1-phase, 60 Hz AC power and moves up to 1,385 cubic feet per minute of heated air at high fire. At 141 pounds and 21 inches wide, it fits standard residential utility closet and alcove installations. Licensed HVAC contractors install and commission this furnace as part of a complete ducted forced-air heating system.\u003c\/p\u003e\u003cp\u003eThis furnace is designed for downflow and horizontal ducted installations in residential and multi-family applications where high efficiency and multi-speed ECM blower operation are required. The 4-ton nominal cooling capacity pairing makes it a practical match for split-system cooling configurations where the furnace serves as the air handler. The Non-NOx burner design meets low-emissions requirements in markets where NOx output limits apply. The temperature rise range at high fire is 40 to 70 degrees F, which guides duct system sizing and static pressure balancing during commissioning.\u003c\/p\u003e\u003ch4\u003eKey Features\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e96 AFUE efficiency rating reduces fuel consumption compared to standard 80 AFUE equipment\u003c\/li\u003e\n\u003cli\u003eSingle-stage gas valve with multi-speed ECM blower motor for quiet, efficient airflow management\u003c\/li\u003e\n\u003cli\u003eNon-NOx burner design for compliance in low-emissions jurisdictions\u003c\/li\u003e\n\u003cli\u003eHigh-fire airflow of 1,385 CFM supports 4-ton nominal cooling capacity\u003c\/li\u003e\n\u003cli\u003eDownflow and horizontal installation configurations supported in a single unit\u003c\/li\u003e\n\u003cli\u003eANSI certified for safe operation in ducted residential and multi-family systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eCompatibility\u003c\/h4\u003e\u003cp\u003eDesigned for ducted downflow and horizontal forced-air heating applications with a nominal cooling pairing of 4 tons (48,000 BTU\/h). Compatible with standard 21-inch-wide duct cabinet and coil configurations. Verify static pressure, gas supply, and electrical rough-in against local mechanical code requirements before installation.\u003c\/p\u003e\u003ch4\u003eInstallation Notes\u003c\/h4\u003e\u003cp\u003eInstallation must be performed by a licensed HVAC contractor in accordance with the current edition of the IFGC, NFPA 54, and applicable local codes. Shut off gas supply and disconnect electrical power before any service work. The unit requires a dedicated 115-volt, 20-amp maximum overcurrent protection circuit with a minimum circuit ampacity of 13.7 amps. Do not exceed the temperature rise range of 40 to 70 degrees F at high fire; verify actual rise after startup and adjust airflow as needed to remain within range.\u003c\/p\u003e\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAFUE\u003c\/strong\u003e: 96%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Fire Input Capacity\u003c\/strong\u003e: 80,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Fire Output Capacity\u003c\/strong\u003e: 76,880 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Cooling Capacity\u003c\/strong\u003e: 48,000 BTU\/h (4 Ton)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Rise Range (High Fire)\u003c\/strong\u003e: 40-70 degrees F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAirflow Rate (High Fire Heating)\u003c\/strong\u003e: 1,385 CFM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Voltage\u003c\/strong\u003e: 115 volts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Phase\u003c\/strong\u003e: 1-Phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Frequency\u003c\/strong\u003e: 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Type\u003c\/strong\u003e: AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMin. Circuit Amps\u003c\/strong\u003e: 13.7 amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Overcurrent Protection\u003c\/strong\u003e: 20 amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower Motor Horsepower\u003c\/strong\u003e: 0.75 HP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Speed Type\u003c\/strong\u003e: Multi-Speed ECM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Valve Type\u003c\/strong\u003e: Single Stage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBurner Type\u003c\/strong\u003e: Non-NOx\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Configuration\u003c\/strong\u003e: Downflow\/Horizontal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Width\u003c\/strong\u003e: 21 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Height\u003c\/strong\u003e: 34.5 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Depth\u003c\/strong\u003e: 28.875 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower Diameter\u003c\/strong\u003e: 11 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlower Width\u003c\/strong\u003e: 10 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Weight\u003c\/strong\u003e: 141 pounds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat Exchanger Type\u003c\/strong\u003e: Gas\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Type\u003c\/strong\u003e: Indoor Ducted\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eANSI Certified\u003c\/strong\u003e: Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Parts Warranty (Residential)\u003c\/strong\u003e: Heat Exchanger 20 Years; All Parts 5 Years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegistered Parts Warranty (Residential)\u003c\/strong\u003e: Heat Exchanger 79 Years; All Parts 10 Years\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Parts Warranty (Commercial)\u003c\/strong\u003e: Heat Exchanger 20 Years; All Parts 5 Years\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eStandard Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: GOODMAN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: ad9s960804cn\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"AMANA","offers":[{"title":"Default Title","offer_id":51138492563762,"sku":"AD9S960804CN","price":3660.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0270\/4519\/9983\/files\/305533686.png?v=1782250743","url":"https:\/\/voomisupply.com\/products\/goodman-ad9s960804cn-96-afue-gas-furnace-80000-btu-h","provider":"Voomi Supply","version":"1.0","type":"link"}